Page 1: ...rench or sanitary connection For French drain place a minimum of three cubic feet of gravel under drain opening Local soil conditions may require more gravel drainage Refill trench and hole compacting back fill as required Leave sufficient depth in hole to accommodate concrete pour Page 1 of 3 9938 159 M01 07 21 14 Valve Specifications Minimum Maximum Pressure 30 100 PSI Prepare the slab area surr...
Page 2: ...te as required Check all connections for leaks All normal maintenance is done from above ground v Always shut off water supply when doing any maintenance v To remove pushbutton assembly remove bowl from housing From inside of the housing remove inlet and outlet lines from push in ports of valve body Using a spanner wrench remove pushbutton and retaining ring v To replace regulator use a spanner wr...
Page 3: ...Cut to fit length of 1 4 PE tubing and remove any burrs or sharp edges Ensure that the outside diameter is free from score marks Tube ends should be square INSERTING THE TUBE 1 Firmly and fully insert the tubing end into the push in fitting up to the tube stop located approximately deep COLLET COLLET O RING O RING TUBE STOP COLLET COLLET COLLET WATER COOLERS I N S TA L L AT I O N M A I N T E N A N...