A172-UG SERIES UNIVERSAL BI-LEVEL DRINKING FOUNTAIN
(Standard Configuration Left Unit High with Right Unit Low)
ROUGHING-IN AND DIMENSIONAL DRAWING
Prior to roughing consult with local, state, and federal codes for proper mounting height.
NOTES:
Adjust vertical dimensions as required to comply with federal, state, and local codes.
Dimensions indicated are for ADA frontal approach installation. For Child ADA compliant parallel
approach installation, decrease height of installation for spout to be 30” maximum above finished floor.
Provide clear floor space as required. Adjust vertical dimensions as required to comply with federal,
state, and local codes.
A172-UG
Page 2 of 17
Date: 09/01/2020
7020-984-001
MURDOCK MFG. •
15125 Proctor Avenue • City of Industry, CA 91746 USA
Phone 800-453-7465 or 626-333-2543 • Fax 626-855-4860 • www.murdockmfg.com
Member of
I N S TA L L AT I O N / M A I N T E N A N C E I N S T R U C T I O N S
DRINKING FOUNTAIN
1-1/4" [32] O.D.
TAILPIECE FOR
P-TRAP BY
OTHERS
1
3
8
"
[35]
6"
[151]
12"
[305]
*33"
[838]
6"
[152]
D
E
C
B
A
GENERAL NOTES:
1. ALL DIMENSIONS ARE IN INCHES [MM]
2. ALLOW 4 INCHES [102MM] MINIMUM CLEARANCE PER SIDE FOR
VENTILATION
3. DIMENSIONS SHOWN ARE FOR ADA ADULT HEIGHT. ADJUST
VERTICAL DIMENSIONS AS NECESSARY TO COMPLY WITH
FEDERAL, STATE & LOCAL CODES
4. STOP VALVE, P-TRAP & ELECTRICAL OUTLET NOT SUPPLIED
5. IMPORTANT: COOLERS MUST BE ATTACHED TO WALL WITH
APPROPRIATE ANCHOR SCREWS
A. 3/8" O.D. SUPPLY INLET
B. WASTE OUTLET FOR P-TRAP BY OTHERS FOR PROVIDED
1-1/4" O.D. TAILPIECE
C. ELECTRICAL SERVICE ROUGH (IF REQUIRED)
D. Ø3/8" HANGER BRACKET PUNCHING, 6 PLACES ON EACH
FIXTURE FOR ANCHORING HARDWARE BY OTHERS
E. Ø1/4" PUNCHING, 2 PLACES ON EACH FIXTURE FOR
ANCHORING HARDWARE, BY OTHERS
F. PUSHBUTTON ASSEMBLY OR SENSOR
*
2"
[51]
3
3
4
"
[95]
*15
7
8
"
[403]
*17
7
8
"
[454]
1
3
8
"
[35]
3"
[76]
*30
5
8
"
[778]
2"
[51]
6"
[152]
2"
[51]
*36
5
8
"
[930]
7
7
8
"
[200]
TYP
6
3
8
"
[163]
12
3
4
"
[324]
4
1
4
"
[108]
D
E
F
18
5
8
"
[473]