Page 5 of 25
SYNCSEL
MODE
FF
FTUNE
SS
Fixed
frequency
Asynchronous
Cycle
skip
Divide
by
2
Divide
by
3
No
function
No
function
No
function
No
function
Nominal
15%
‐
15%
600mA
2.1A
1.1A
Figure 3. Typical Jumper Settings and Options
EVK Connection
Connect the EVK and the measuring equipment as shown in Figure 4.
Adjustable
bench
power
supply
15V
max
5A
+Ve
‐
Ve
+Ve
sense
‐
Ve
sense
Adjustable
electronic
load
+Ve
‐
Ve
+Ve
sense
‐
Ve
sense
DMM
DMM
Figure 4. EVK Connectors