Cold Max. Level: When the outside temperature reaches the Dynamic Maximum Cold
Outside Temperature, Minimum Ventilation will not go above this level.
o
Warm Max. Level: When the outside temperature reaches the Dynamic Maximum
Warm Outside Temperature, Minimum Ventilation will not go above this level.
11.2.2
V
ENTILATION BY
W
EIGHT
•
How Does Ventilation by Weight Work
•
Defining the Ventilation By Weight Parameters
11.2.2.1
How Does Ventilation by Weight Work
Ventilation by Weight provides air based on the number of birds in the house, their projected weight, and
the outside temperature. After calculating how much air is required based on these factors, TRIO
determines the required ventilation level to supply the air. Anytime that one of the factors changes, TRIO
recalculates the ventilation (to prevent changing the ventilation too frequently any change must be larger
than a user-defined amount).
•
When using cycle fans, each level has minimum and maximum on times, which determine the
minimum and maximum CFM. If the ventilation doesn't provide enough air for the birds (based on
their numbers and weight) TRIO sends an alarm. You will need to redefine the minimum level.
•
When using variable speed fans, the defined percentages determine the minimum and maximum
CFM. However, if a variable fan is set to run in a cycle, the cycle time determines the fan
operation, not the user-defined fan speed.
11.2.2.2
Defining the Ventilation By Weight Parameters
1. Go to System > Control Strategy > Ventilation
.
2. Under Minimum / Maximum Ventilation, enable Min Ventilation By Weight.
3. Go to Climate > Min/Max Ventilation.
Summary of Contents for TRIO
Page 18: ... Munters AB 2020 18 Figure 5 Relay wiring detailed view Figure 6 Relay and port numbering ...
Page 86: ... Munters AB 2020 86 ...
Page 88: ... Munters AB 2020 88 4 Verify that each channel is enabled ...
Page 170: ... Munters AB 2020 170 Click to view the bird scale data ...
Page 180: ... Munters AB 2020 180 25 3 2TRIO 20 CONTAINER SPARE PARTS ...
Page 182: ... Munters AB 2020 182 25 3 3TRIO 20 DOOR CARD SPARE PARTS ...
Page 184: ... Munters AB 2020 184 25 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Page 196: ... Munters AB 2020 196 Figure 36 Relay and port numbering 26 2 3POWER Figure 37 Power ports ...