Alarm delay: After detecting that a parameter has gone above or below its specs, Trio waits
this amount of time before sending an alarm. This prevents sending alarms for short deviations.
Range: 0 – 999 seconds.
•
Alarm Reminder: Trio will resend an alarm after this amount of time if the alarm is not
acknowledged. Range: 0 – 999 minutes.
•
Water Overflow Max Water/Hour: Trio sends an alarm if the water flow exceeds this amount.
•
Water Shortage:
o
Min Water/Hour: Trio will send an alarm if the water flow is less than this amount.
Range: 0 – 999 gallons/liters.
o
Enable Water Shortage Alarm: Define the period in which the alarm is active, 24 hours a
day or specific time frames.
•
Potentiometer: Enable Potentiometer Alarm: Trio will send an alarm if potentiometer-controlled
inlets are not opening to the required levels. Define the period in which the alarm is active, 24
hours a day or specific time frames.
15.1.2
A
LARM
T
EST
The alarm test confirms that the alarm system is functioning properly. A test can be performed manually at
any time or scheduled weekly or daily.
•
•
15.1.2.1
Manual Test
•
Click
. Stop the test as needed.
15.1.2.2
Scheduled Tests
Scheduled tests can be performed once a day only.
1. On the Alarm Screen, enable Scheduled Alarm Test.
2. Define the day(s) and time at which the test is performed.