Configuring the Temperature Curve
•
Defining the Temperature Curve
•
Defining Temperature Curve Settings
10.2.1
D
EFINING THE
T
EMPERATURE
C
URVE
P
ARAMETERS
1. Go to Climate > Temperature Curve.
2. Configure up to 10 points in the curve.
3. Define:
o
Day: Define the growth day at which each temperature spec applies. Each day must
have a unique number. Range: 0 – 999.
o
Target: Target temperature is the required temperature for the pig house. All ventilation
calculations are based on this specification. Range -40⁰ to +90⁰ C.
o
Zone Heat: This parameter is the set point at which the zone heaters are activated.
o
Cool: This parameter is the set point at which cooling devices are activated. When the
target temperature changes, this number changes accordingly. Range: Target
temperature to +90⁰ C.
NOTE
Zone Heat and Cool appear if a zone heater and cooler are defined in Mapping Devices, page
48.
o
Tunnel: This parameter is the set point at which tunnel ventilation begins. When the target
temperature changes, this number changes accordingly. Range: Target temperature to
+90⁰ C.
NOTE
Zone Heat and Cool only appear if relays are defined as Zone Heaters or Cooler (refer to page
48). Tunnel appears if Tunnel Ventilation is enabled in Ventilation Settings (page 123).
o
Low/High Temperature Alarm: These parameters are differentials from the target
temperature at which Trio sends an alarm. Range:
Low Temp Alarm: -40°- Target
High Temp Alarm: Target - 90°
4. Click
to view the curve history.
Summary of Contents for Rotem Trio 20
Page 20: ... Munters AB 2020 20 Figure 6 Relay and port numbering ...
Page 44: ... Munters AB 2020 44 ...
Page 99: ... Munters AB 2020 99 Refer to Tunnel Ventilation page 123 for more details ...
Page 141: ... Munters AB 2020 141 If an outside temperature sensor is enabled map timers to it if required ...
Page 160: ... Munters AB 2020 160 23 3 2TRIO 20 CONTAINER SPARE PARTS ...
Page 162: ... Munters AB 2020 162 23 3 3TRIO 20 DOOR CARDS SPARE PARTS ...
Page 164: ... Munters AB 2020 164 23 3 4TRIO 20 MAIN CONTAINER SPARE PARTS ...
Page 186: ... Munters AB 2020 186 Figure 33 Relay and port numbering 26 2 3POWER Figure 34 Power ports ...
Page 199: ... Munters AB 2020 199 2 Insert and secure the SMA connector ...
Page 202: ... Munters AB 2020 202 example only ...