![Munters RFS-6 Manual For Use And Maintenance Download Page 12](http://html1.mh-extra.com/html/munters/rfs-6/rfs-6_manual-for-use-and-maintenance_1856977012.webp)
© Munters AB, 2018
12
3.6
Variables
RFS-6 Broiler variables, a brief description and default values are listed below.
Parameter No.
Description
Default Value
1
Mixing Cycles 1-10
1
Number of mixtures for a two auger-unit
2
Maximum Portion 1…60 [Kg / Lb]
25
Maximum weight for one portion, for a manual scale
3
Max Auger Time 0…60 [minutes]
5
Waiting time before the alarm starts in case auger 1, 2 have not
been filled with portion (Alarm Code 5 or 4).
4
Not Empty Time 0…1440 [minutes]
3
Waiting time before the alarm starts in case the auger is not
empty and still contains more than half a portion (Alarm 6).
5
Low Limit 1: 0…65000 [Kg / Lb]
0
If the remaining quantity of feed in Silo 1 is below the low limit,
Alarm 7 is triggered.
6
Low Limit 2: 0…65000 [Kg / Lb]
0
If the remaining quantity of feed in Silo 2 is below the low limit,
Alarm 8 is triggered.
7
Feed / Pulse W Ratio 0…100 [Kg / Lb]
10
Relation between the feed quantity and the number of pulses at
the exit feed / pulse 1.
8
Water / Pulse Ratio 0…100
0.000
Relation between the water quantity and the number of pulses at
the entry water / pulse.
9
Reference [Kg / Lb]
0.000
Weight to which measurements are compared, to check that they
are within the desired range.
10
% Below 10…45 [%]
30
Measurements in %, within the range below the reference weight.
AUTO
ENTER
(+) OR (-)