Installation menu
CAUTION
Always connect temperature and sensor shields to earth ground.
CAUTION
Avoid mixing high voltage wiring with sensor and low voltage wiring.
CAUTION
Keep the controller as far as possible from heavy contactor boxes and other sources of
electrical interference.
•
•
•
•
•
•
•
10.1
Relay Layout
RELAY LAYOUT #01
#
FUNCTION
01
02
Heater 1
Heater 2
Each relay can be defined to any of the functions on the following list:
•
None
•
Heater 1-2
•
Heat lamp 1-2
•
Fan 1-8
•
Cool Pad
•
Foggers
•
Curt. 1-4 open
•
Curt. 1-4 close
•
Tunnel open
•
Tunnel close
•
Inlet open
•
Inlet close
•
Light
•
Feed
•
Circulation
•
Extra system 1-3
•
Timer 1-5
10.2
Sensors Layout
ANALOG INPUT #01
OPTIONS
Temp-1
Temp-2
Temp-3
Temp-4
Humidity
IN
NONE
NONE
OUT
YES
IN / NONE
IN / NONE
IN / NONE
NO / YES/OUT
NO / YES
The Sensor Layout accommodates up to four temperature sensors and one humidity sensor. Three can be
defined for use inside the house and up to one can be used out of the house. Mark "IN" for a temperature
sensor connected in the house and OUT for a temperature sensor outside of the house.
NOTE
Only sensor number 4 can be 'Out'.