the panel. The installation procedure consists of fastening the hooks for these latches onto the
fan. To do this, follow the steps below:
1. Fold the screw hole marking guide as shown in figure 2.
2. Four hooks should be installed, two on the top side and two on the bottom side of the fan.
The locations of these are indicated in figure 3.
3. Measure the right distance from the sidewall of the fan, and mark the spot. For a FI50
measure 248mm; for a FI36 measure 198mm; for a FI30 measure 171mm; and, for a FI24
measure 136mm. Do the same for all four locations as indicated in Figure 4.
4. Use the screw hole marking guide and place the rectangular opening over the spot
previously marked. Now mark the location of the two holes as indicated in figure 5. Do the
same for all four locations.
5. Use a hammer and centre punch and punch the location of all 8 screws as indicated in
Figure 6.
6. Use an electric drilling machine and an appropriate bit to drill the self tapping / self drilling
screws into the fan, thereby fastening the hook as indicated in figure 7. Do the same for all
four hooks.
Figure 3
Figure 4
Figure 2