Munters EDC GHp Series Manual For Use And Maintenance Download Page 23

23

 |

 © Munters AB, 2020 

Spare parts - EDC18 GHp 

REF. 

DESCRIPTION 

QUANTITY 

EYEBOLT M6 

SAFETY MESH 

CAGE NUT M6 

M8x25 HEX SCREW W/FLANGE 

D8 EXT TOOTHED WASHER 

PROPELLER 

M5x16 HEX SCREW  

D5 SPRING WASHER 

D5x20 PLAIN WASHER 

10 

HUB 

11 

POP UP RIVET D3.9x7 ALU 

12 

HOUSING 

13 

M6 HEX NUT 

14 

RUBBER FOR CABLE 

15 

M6x25 HEX SCREW W/FLANGE 

12 

16 

MOTOR 

17 

D6 SPRING WASHER 

18 

MOTOR PLATE 

19 

D6 SPRING WASHER 

20 

MOTOR PLATE SUPPORT

 

21 

D6x18 PLAIN WASHER 

 

 

 

Summary of Contents for EDC GHp Series

Page 1: ...Manual for use and maintenance EDC GHp Air circulation fan Models EDC18 GHp EDC24 GHp Ag MIT UmEN 2752 02 20 Rev 1 0 EDC GHp ...

Page 2: ...l developments and to make alterations to specifications quantities etc for production or other reasons subsequent to publication Warranty For Warranty information please refers to General terms and condition of sale available on https www munters com globalassets terms and policies condizioni_generali_vendita pdf Conditions and Limitations Products and Systems involved in a warranty claim under t...

Page 3: ...rt 9 3 3 Structure 9 4 OPERATING CONDITIONS 10 4 1 Intended conditions of use 10 4 2 Non permitted conditions of use 10 5 INSTALLATION 13 5 1 Choice of site and checking installation requirements 13 5 2 Placement of fans 13 5 3 Connection to the electrical system 14 5 4 Use 17 6 COMMISSIONING 18 7 TECHNICAL DATA 19 7 1 Dimensions 19 7 2 Motor specifications 20 7 3 Technical specifications 20 8 MAI...

Page 4: ...ly Before installation or using the fan this manual should be studied carefully It is also recommended that it is kept safely for future reference The manual is intended as a reference for installation commissioning and day to day operation of the Munters fans 1 3 Notes Date of release 2020 Munters cannot guarantee to inform users about the changes or to distribute new manuals to them All rights r...

Page 5: ...the use of the machine first aid procedures fire precautions and evacuation of workplaces devices provided for the safety of operators and residual risks generated by the machine In particular the employer has the following duties when assigning tasks to operators to take into account their capabilities in the interests of safeguarding their health and safety to provide adequate means of protectio...

Page 6: ...turer adopted the necessary technical solutions to ensure compliance with fundamental safety requirements the object of the risk reduction process was to ensure that the operator can use the fan in safety The machine is provided with protection devices of fixed type and is fitted with an actuator for the emergency stop function Fixed guards The fixed guards are solidly fixed to the structure of th...

Page 7: ...ilure to observe ergonomic principles caused by excessive strain i e generic mechanical hazard during the moving and installing stages of the machine Electrical hazards System area Description Plates provisions PPE Panels covers and electrical apparatus The safety signs must be fixed in an extremely visible position on the door of the electrical panel and on covers containing electrical apparatus ...

Page 8: ... on the overall level of sound pressure in the installation area and the daily personal exposure of the employees In areas where the overall sound level reaches excessive values personal protective equipment must be used WARNING The fan must only be used if it is in perfect operating condition by personnel aged more than 14 years who are perfectly aware of the safety measures and possible hazards ...

Page 9: ...andles or grips Consequently one of the following alternatives should be used trolley forklift crane fix two bolts in the M8 bushes situated on the fan housing and hook the lifting cable over the bolts WARNING Make sure a steel cable or rope of adequate size is being used when the fan is lifted by crane Fan weights are shown in the technical specification table see section 7 2 3 3 Structure Air Ci...

Page 10: ...should be taken into consideration fig 1 The fan has been designed and built to operate in safety for the user if used according to the conditions intended by the manufacturer and stated in this user and maintenance manual NOTE For further information please refer to the technical documentation attached to this manual 4 2 Non permitted conditions of use Total or partial failure to observe the inst...

Page 11: ... it is essential to maintain the safety and operational characteristics of the original device preferring replacement with an identical component Insufficient maintenance A correct normal maintenance is one that maintains the original integrity or restores the fan s efficiency while at the same time limiting normal deterioration resulting from use Special maintenance work can also prolong the usab...

Page 12: ... in a classified area according to directive 1999 92 EC WARNING The metal sheets used for constructing the fan housing and shutter blades have a surface coating made of an alloy of Zinc Aluminum and Magnesium classified as Zm120 equivalent to 9 μm of coating thickness on each side of the panels which corresponds to a corrosion resistance in salty mist of 1800 hours Whenever it is intended to use t...

Page 13: ...red as fixed speed Upon request we can supply fans with the following features multispeed where the speed variation can be made by using ONLY an autotransformer multispeed with inverter or VFD where the variation of speed is made by using an inverter Variable Frequency Drive The multispeed machines cannot in any way be regulated by an inverter and the multispeed with inverter machines cannot in an...

Page 14: ... in accordance with the instructions in standards IEC EN 60204 1 and IEC 60364 The electrical panel of the fan must generally be equipped with the following devices bearing EC marking as per directive 2006 95 EC fig 2 Lockable isolating switch fig 3 Magnetothermic switch chosen to suit the power of the motor The need to fit a switch of differential type depends on the configuration of the electric...

Page 15: ...le with the nominal current of the motor or main panel for managing the equipment with control devices which act on the electrical supply to the fan WARNING Do not supply power to the fan during installation stage Installer must issue a declaration of correct installation in accordance with applicable legislation in the country of use Below are suggested wiring diagrams for connecting the fan to t...

Page 16: ...ke an effective earth connection they must have isolating devices and automatic protection against overload and short circuits Before activating the electrical supply to the machine by turning the isolator switch to position On a series of checks must be made check that the voltage and frequency of the power source correspond to those indicated in the equipment technical data and electrical diagra...

Page 17: ...rough not supplied equipments Operating conditions Looking at the airflow rectifier the propeller should turn counterclockwise fig 8 fig 5 Emissions in the atmosphere If used as an air extractor the user should carry out the checks and fulfilments in compliance with the regulations about the inflow of polluting substances into the atmosphere Cleaning During cleaning operations the power switch mus...

Page 18: ... to turn 5 remove all obstacles from the front and back sides of the fan 6 ensure that all people and animals are standing clear of the fan 7 turn the electrical power to the fans on 8 observe the direction in which the propeller of each of the fans is turning 9 turn the electrical power to the fans off WARNING Do not attempt to correct any problem observed during the above mentioned steps while t...

Page 19: ...19 Munters AB 2020 7 TECHNICAL DATA 7 1 Dimensions Dimensions fig 6 A B C D EDC24 GHp 620 275 580 305 EDC18 GHp 470 275 350 305 ...

Page 20: ... 0 5 hp Weight of fully equipped air circulator kg 14 14 20 Nominal propeller speed rpm 1400 1400 900 Airflow at 0 Pa m3 h cfm 3950 2325 5260 3095 7800 4590 Specific performance at 0 Pa m3 Wh cfm W 9 2 5 4 8 5 5 0 17 10 Propeller diameter mm inch 450 18 450 18 600 24 Number of blades 6 6 6 IEC protective class of electric motor IP55 IP55 IP55 Electric motor winding insulation grade F F F Max noise...

Page 21: ...en the fixing screws and remove the safety mesh unscrew the bolts fixing the motor bracket to the body pull the motor propeller group out of the body and replace the damaged propeller reassemble the circulator following the reverse procedure WARNING Do not operate the fan with the safety protections removed safety meshes can be removed only with specific tools by qualified technicians when the fan...

Page 22: ...22 Munters AB 2020 SPARE PART LIST Exploded view EDC18 GHp ...

Page 23: ...5 D8 EXT TOOTHED WASHER 4 6 PROPELLER 1 7 M5x16 HEX SCREW 4 8 D5 SPRING WASHER 1 9 D5x20 PLAIN WASHER 1 10 HUB 1 11 POP UP RIVET D3 9x7 ALU 4 12 HOUSING 1 13 M6 HEX NUT 8 14 RUBBER FOR CABLE 1 15 M6x25 HEX SCREW W FLANGE 12 16 MOTOR 1 17 D6 SPRING WASHER 4 18 MOTOR PLATE 1 19 D6 SPRING WASHER 4 20 MOTOR PLATE SUPPORT 1 21 D6x18 PLAIN WASHER 4 ...

Page 24: ...24 Munters AB 2020 Exploded view EDC24 GHp ...

Page 25: ...5 M8x25 HEX SCREW W FLANGE 12 6 D8 EXT TOOTHED WASHER 4 7 PROPELLER 1 8 M8 HEX NUT 8 9 MOTOR PLATE SUPPORT 1 10 RUBBER FOR CABLE 1 11 HOUSING 1 12 POP UP RIVET D3 9x7 ALU 4 13 M6x25 HEX SCREW W FLANGE 4 14 D8 SPRING WASHER 8 15 MOTOR PLATE 1 16 MOTOR 1 17 ALUMINIUM HUB 1 18 WASHER D8X32 1 19 D6 SPRING WASHER 1 20 M6X20 HEX SCREW 1 ...

Page 26: ...unters cn Denmark Phone 45 98 623 311 aghort munters dk Germany 49 0 25 58 93 92 0 India Phone 91 20 6681 8900 info munters in Indonesia Phone 66 2 642 2670 info munters co th Israel Phone 972 3 920 6200 info munters co il Italy Phone 39 0183 5211 info munters it Japan Phone 81 3 5970 0021 mkk munters jp Korea Phone 82 2 7618 701 munters munters co kr Mexico Phone 52 818 2625 400 dhinfo munters co...