Running In

High quality drivers are used in the EGG100 Monitoring Systems. When new, they will reach their optimum working 

performance after approximately 24 hours of operation and, after that, should still be allowed to warm up before 

serious mixing is carried out. 

Frequency Response

Reference Data

Frequency Response

60Hz to 20KHz (-3dB points)

Low Frequency Room Calibration

+0/-10dB at 63 Hz continuously variable

High Frequency Calibration

+1/-5dB at 10kHz continuously variable

Setting up your System

70
65
60
55
50
45
40
35
30

100

1,000

10,000

[dBV/dBV]

Frequency [Hz]

Frequency Response at 0 and 30 degrees Horizontal

70
65
60
55
50
45
40
35
30

100

1,000

10,000

[dBV/dBV]

Frequency [Hz]

Response at 0 degrees

Response at 30 degrees

Summary of Contents for EGG100

Page 1: ...Operation Manual...

Page 2: ......

Page 3: ...ORING SYSTEM Input Amplifier Front Panel Pg 4 Input Amplifier Rear Panel Pg 5 Input Amplifier Side Panel Pg 5 SETTING UP YOUR SYSTEM Setup and Operation Pg 6 Positioning Pg 6 Equalisation Pg 7 Control...

Page 4: ...lity components and extensively tested to ensure years of trouble free operation If something goes wrong you won t get left without your speaker system If you register your product at www MunroSonic c...

Page 5: ...one of the correct value 1 2 3 EGG100 Monitoring System INPUT AMPLIFIER SIDE PANEL HF TRIM The HF trim pots are designed to give absolute precision alignment of each channel and adjustment for persona...

Page 6: ...f a computer monitor or TV screen The EGG100 system includes custom moulded vibration damping nests for the EGGs to sit in These serve several functions and are intended to facilitate the exact alignm...

Page 7: ...applications Control Unit The EGG is unique in that all the electronics are housed in a separate unit that can be placed within reach of the operator and within the listening area This has several im...

Page 8: ...s mixing is carried out Frequency Response Reference Data Frequency Response 60Hz to 20KHz 3dB points Low Frequency Room Calibration 0 10dB at 63 Hz continuously variable High Frequency Calibration 1...

Page 9: ...rnal volume 14 Litres Two way passive crossover 25mm HF unit sensitivity 95dB SPL for 1 W at 1m 100mm LF unit sensitivity 86dB SPL for 1 W at 1m Thermal tweeter protection with automatic cut out and r...

Page 10: ...iately disconnect the mains plug from the wall and have your system inspected by a qualified technician Only use the voltage as specified as correct for the system supply Always attach the three pin a...

Page 11: ......

Page 12: ...3 Hunting Gate Hitchin Hertfordshire SG4 0TJ United Kingdom Tel 44 0 845 500 2 500 www MunroSonic com...

Reviews: