NOTE: The control panel of the unit you purchased may be slightly different according to the
models.
Fig.1
CONTROL PADS ON THE DESHUMIDIFIER
32
1
2
3
4
5
6
7
Unit operation on
indicator light
8
Fan speed
indicator light
Wireless operation
on indicator light
Bucket full
indicator light
Continuous
operation on
indicator light
Dryer operation
on indicator light
Smart dehumidifying
operation on indicator
light
Timer
indicator light
Control pads
3
When you push the button to change
operation modes, the unit will make
a beep sound to indicate that it is
changing modes.
2
Humidity Set Control Pads
: Up/Down Pads
TIMER Set Control Pads
Use the Up/Down pads to set the Auto start and
Auto stop time from 0.0 to 24.
The humidity level can be set within a range of
35%RH(Relative Humidity) to 85%RH(Relative
Humidity) in 5% increments.
For drier air, press the pad and set to a lower
percent value(%).
For damper air, press the pad and set a higher
percent value(%).
5
Timer Pad
Press to initiate the Auto start and Auto stop
feature, in conjuction with the and pads.
1
4
Power Pad
Press to turn the dehumidifier on and off.
Mode Pad
Press to select the desired operation mode from
Dehumidifying,Dryer,Continuous dehumidifying and
Smart dehumidifying.
NOTE: Dryer and Smart dehumidifying modes are
optional.
6
Fan Pad
7
Wireless Pad (optional)
Press this pad for 3 seconds to initiate the
Wireless connection mode. The LED DISPLAY
shows 'AP' (at this time the unit shuts off all other
functions) to indicate you can set Wireless
connection. If connection(router) is successful
within 8 minutes, the unit will exit Wireless
connection mode automatically and the Wireless
indicator illuminates and the unit enters the
previous functions. If connection is failure within
8 minutes, the unit exits the Wireless connection
mode automatically.
Control the fan speed. Press to select
fan speed in three steps-low, med and
high. The fan speed indicator light
illuminates under different fan speed
settings. But when select high fan speed,
both the low and med fan speed lights
illuminate.
NOTE: When the compressor startups or stops
running, the unit may make a loud voice, it is normal.
Display
Shows the set % humidity level from 35% to 85% or
auto start/stop time (0~24) while setting, then shows
the actual (¡5% accuracy) room % humidity level
in a range of 30%RH(Relative Humidity) to 90%RH
(Relative Humidity).
Error Codes and Protection Codes:
AS
- Humidity sensor module error--Unplug the unit
and plug it back in. If error repeats, call for service.
8
P2
- Bucket is full or bucket is not in right position-- Empty
the bucket and replace it in the right position.
ES
- Temperature sensor error-- Unplug the unit and
plug it back in. If error repeats, call for service.