Confirm that there is enough room for installation and mainte-
nance. 

5.    INSTALLATION SPACE

Fig.5-2

Fig.5-1

Maint enance roomage

Maint enance roomage

checking orifice

or

 m

o

re

600mmX600mm

50

0m

m

or

 m

o

re

600

mm

checking orifice

  Confirm the minimum 
drain tilt is 1/100 or more

Cover the pipe before connecting to keep rubbish, dust or other 
impurities out. 

 

6.    REFRIGERANT PIPE

Gas side

Piping

Capaticyl(KW)

Piping material

Copper special for air conditioner

         7.1/8/9/11.2/14/16/20/25/28

15.9

9.52

Liquid side

Table.6-1

The indoor unit show as 

Fig.4-20

Following 

Fig.4-21

 twist-off the screws, along the direction of A 

get off the cover plate A and cover plate B. 

Dismounting bolt A

Dismounting bolt C

Along the direction of B and C divided the part B and part C of 
indoor unit.

The part A and part B of indoor unit individual put into the 
positionsite, then install the indoor unit following

 the reverse 

order of step 2,3,4 and 5.

Maintenance of motor

  
 

1

2

3

4

5

As figure dismounting the bolt of bottom,get down the bottom 
cover plate.

As figure dismounting 6 bolts in the front plate.

Support the fan subassembly from the bottom, then litter up,  get 
down fan subassembly.

After finished maintenance of motor, then install the motor 
assembly in the reverse order of step 1,2 and 3.

During this process,the indoor unit don’t need dismounted.

  

1

2

3

4

5

6

Fig.4-12

bolt

motor 
assembly

bottom 
cover plate

screw

pothook

scroll

NOTE

During teardown and installation, the scroll was allowed direct 

support by hand

Fan subassembly is more weightiness, please take careful 

during teardown and installation, and keep from hurt by fan 

subassembly.

  

maintenance of motor

˖

0 1 2

F

3

E

4

D

5

C

6

B

7

A

89

Installation manual

10

High pressure duct

Summary of Contents for CL23904

Page 1: ...CL23380 to CL23383 High Pressure Duct MVD DC Installation manual English www mundoclima com MVD...

Page 2: ...car or in the cabin In the kitchen or a place full of oil steam There is strong electromagnetic wave CONTENTS PAGE INSTALLATION PRECAUTION 1 INSTALLATION PLACE 1 ACCESSORIES 2 INDOOR UNIT INSTALLATION...

Page 3: ...out Especially in case there is a ceiling position the refrigerantpipes drainpipes indoor outdoorlinestotheconnec tion places before hanging up the machine The installation of hanging screw bolts Ins...

Page 4: ...of the main body While choosing where to start the operation determine the direction of the position the refrigerant pipes drain pipes indoor outdoor lines and line controlled lines to the connection...

Page 5: ...11 28 169 691 52 35 136 123 179 15 ELECTRICAL CONTROL BOX PLASTIC COVER 930 135 88 24 46 68 82 82 56 270 420 249 29 722 65 75 61 43 189 123 642 420 85 856 214 86 800 44 253 155 189 123 26 255 33 65 RE...

Page 6: ...Fig 4 11 2 Remove the all 11 screw from fixed Safety Drain Tray and then take off the tray as figure showed in Fig 5 11 3 Take off the tray along the direction of the arrow show in Fig 4 12 4 Clean th...

Page 7: ...3 Refer to Fig 4 13 remove all 4 bolts from fan assembly see Fig 4 14 according to which orders to take off the fan assembly 4 Refer to Fig 4 14 horizontal pushing the fan assembly until it cannot no...

Page 8: ...ray and then take off the tray as figure showed in Fig 4 16 3 Take off the tray along the direction of the arrow show in Fig 4 16 4 Clean the tray and evaporator 5 Re install the unit follow the rever...

Page 9: ...rding to which orders to take off the fan assembly 3 Refer to Fig 4 18 horizontal pushing the fan assembly until it cannot not move any further and then lift up slightly and take down to remove it 4 A...

Page 10: ...lt A bolt C Installation manual 9 High pressure duct 1121 75 343 96 60 4 10 hanging screw configure on spot Air intake Air outlet Refrigerant pipe flared connection 16 5 8 Refrigerant pipe flared conn...

Page 11: ...the part B and part C of indoor unit The part A and part B of indoor unit individual put into the positionsite then install the indoor unit following the reverse order of step 2 3 4 and 5 Maintenance...

Page 12: ...00 1800 2200 2600 3000 3400 3800 4200 0 20 40 60 80 100 120 140 160 180 200 220 1400 1800 2200 2600 3000 3400 3800 4200 MVD 160T1 DHN1 B HIGH FAN SPEED MIDDLE FAN SPEED LOW FAN SPEED MVD 200T1 DHN1 B...

Page 13: ...the outside frame tightly to the ceiling and fix it Fig 7 15 Hang up the outside frame until it sticks to the ceiling tightly Canvas air passage Ceiling Outside frame Air passage Main body Waist shape...

Page 14: ...enable pipe The bending angle should not exceed 90 Bending position is preferably in the bendable pipe The larger the better it is Do not bend the pipe more than three times Bend the connecting pipe o...

Page 15: ...NT PIPE CONNECTION 9 1 Expel The Air Fig 9 1 Flaring Cut a pipe with a pipe cutter Insert a flare nut into a pipe and flare the pipe 90 lean crude burr A 90 4 _ 4 5 2 _ Outside diameter A mm Max 8 7 6...

Page 16: ...low zero Then fasten the nut When the pumping has finished close the Lo lever of the manifold valve completely and turn off the vacuum pump When you have pumped for over 15 minutes please confirm that...

Page 17: ...se power of air condictioners The wiring of 71 to 160 indoor unit please refer to Fig 11 1 and Fig 11 2 is the communication wiring for 200 250 and 280 indoor unit The reserved function is indicated i...

Page 18: ...P5 XS4 XP4 NEW DISPLAY BOARD WIRE CONTROLLER CN16 CN29 CN3 Y G CN23 FAN1 TA T1 T2 T2B C S EEV XP1 XP5 XS1 XS5 XT1 XT2 XT3 PUMP BD 1 BLACK For 200 250 280 models REACTOR CN13 T2 A XS1 XP1 T2B A T1 A XP...

Page 19: ...c pressure range which means the airflow noise and dehumidification are all in the best state 81 120Pa 121 170Pa 171 200Pa 61 120Pa 121 170Pa 171 200Pa 2 3 4 ENC2 Table 12 2 6 definition 00 means shut...

Page 20: ...01 means shutting down the unit to stop cold air at 20 unit to stop cold air at 24 unit to stop cold air at 26 6 definition 00 means the time of stopping TERMAL fan is 4 minutes 01 means the time of s...

Page 21: ...Run LED flash or show E2 Run LED flash or show E3 Run LED flash or show E4 Timer LED flash slowly or show E6 Defrost LED flash slowly or show E7 Alarm LED flash slowly or show Ed Alarm LED flash or s...

Page 22: ...er please refer to the manual of the outdoor unit you choose Fig 15 3 Fig 14 1 Bypass A Bypass B Gas pipe A Gas pipe B Liquid pipe A Liquid pipe B Liquid lines A and B are joined by a distributor The...

Page 23: ...air conditioner under the mode of COOLING with the remote controller and check the following points per the Owner s Manual If there is any malfunction please resolve it through chapter Troubles And Ca...

Page 24: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com MVD...

Reviews: