background image

 

 

MVD

Installation manual

English

CL23220 to CL23223

Console

www.mundoclima.com

Summary of Contents for CL23220

Page 1: ...MVD Installation manual English CL23220 to CL23223 Console www mundoclima com...

Page 2: ...The appliance shall not be installed in the laundry Before obtaining access to terminals all supply circuits must be disconnected The appliance must be positioned so that the plug is accessible The en...

Page 3: ...t 1 meter away from televisions or radios in order to prevent image interference or noise Depending on the radio waves a distance of 1 meter may not be sufficient enough to eliminate the noise The app...

Page 4: ...improvement without further notices Cautions on remote controller installation Remote controller holder Mounting screw B ST2 9x10 C H QUANTITY SHAPE NAME 1 Hook 8 Installation manual 3 Remote control...

Page 5: ...under which the electric wave is generated even if 1 meter is kept When run some of the units among the indoor units in heating mode voice of refrigeration flowing comes from some other non operating...

Page 6: ...oor unit Refer to Fig 5 5 Fig 5 6 Fig 5 8 Fig 5 4 195mm Hook Tapping screw Washer mm Removing front grille 1 Open the front panel 2 Remove the 4 screws and remove the front grille while pulling it for...

Page 7: ...ation purpose only They may be slightly different from the air conditioner you purchased depend on model The actual shape shall prevail The outlet has PTI screw bread Please use sealing materials and...

Page 8: ...o Fig 7 3 Fig 7 3 Remove the front panel 2 Remove the string Refer to Fig 7 2 Allowing the front panel to fall forward will enable you to remove it Fig 7 2 Cover the joints of the connecting pipe with...

Page 9: ...turn the valve clockwise with the hexagon wrench Securely tighten the valve until the shaft contacts the main bodyseal CAUTION CAUTION Always use a charge hose for service port connection After tighte...

Page 10: ...o apply for products like washing machines air conditioners or electrical ovens The temperature of refrigerant circuit will be high please keep the interconnection cable away from the copper tube 1 2...

Page 11: ...erminal block of indoor and outdoor units Re install the Indoor unit and outdoor unit The Specification of Power 8 3 8 4 Wiring of Indoor Unit Power Supply and Signal Wire The indoor unit should use d...

Page 12: ...0 C For the third code ON super high fan speed OFF extreme super high fan speed 1 2 3 Temperature corrected code 0 means in the heating T1 TS 0 C the units capacity should be 0 Temperature corrected...

Page 13: ...r fan is 4 minutes 01 means the time of stopping indoor fan is 8 minutes 10 means the time of stopping indoor fan is 12 minutes 11 means the time of stopping indoor fan is 16 minutes 6 21 6 21 6 21 6...

Page 14: ...and then switch on it If you don t switch on the power the capacity you set can not implement Installation manual Cassette 4 way compact 13 Table 10 1 NO Type Contents LED Lamp flash Remarks The evapo...

Page 15: ...conditioner is pre heated by turning on the power Set the air conditioner under the mode of COOLING with the remote controller and check the following points If there is any malfunction please resolv...

Page 16: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 MVD www mundoclima com...

Reviews: