mundoclima AEROTHERM V17 Owners And Installation Manual Download Page 10

Use '''

ǃ

''''to scroll .Press ''OK'' to select. 

 
 If the weather TEMP.SET is actived,the desired temperature can not 
be adjusted on the interface.Press the ''''

ǃ

'''' to adjust the 

temperature on home page. The following page will appear: 
 
 

 If you want to use heat mode , you select ''HEAT MODE LOW 
TEMP''. If you want to use cool mode, you select ''COOL MODE LOW 
TEMP''. You can select the low or high temperature setting for 
heating or cooling to see the “Table 1~8”. If you select ''ON'', the 
following page will appear: 

 WEATHER TEMP. SET have four kinds of curves :1.the curve of 
the high temperature setting for heating, 2.the curve of the low 
temperature setting for heating, 3.the curve of the high temperature 
setting for cooling, 4.the curve of the low temperature setting for 
cooling.
It only have the curve of the high temperature setting for heating, if  
the high temperature is set for heating.
It only have the curve of the low temperature setting for heating, if  
the low temperature is set for heating.
It only have the curve of the high temperature setting for cooling, if 
the high temperature is set for cooling.
It only have the curve of the low temperature setting for cooling, if the 
low temperature is set for cooling.

 See FOR SERVICEMAN> COOL MODE SETTING and >

HEAT MODE SETTING in installation & owner's manual.

 The desired temperature (T1S) can’t be adjusted, when the 
temperature curve is set ON.

WEATHER    TEMP. SET  TYPE:

WEATHER    TEMP. SET

SCROLL

CONFIRM

OK 

1 2 3 

5 6 7 8 

6.2.3 ECO MODE 

Use ECO MODE is used to save energy during the night . 
If ECO mode is activated,      is displayed on the home page 
Go to ''MENU'' > ''PRESET TEMPERATURE'' > ''ECO MODE''. 
Press ''OK'' . The following page will appear: 

Press ''ON/OFF'' . The following page will appear: 

        5:30  08-08-2016 SAT.

Weather temp.set function is

on. Do you want to turn off it?

SCROLL

ENTER

OK 

         NO 

         YES 

INFORMATION

Move to “NO”,press “OK” to come back to home page,move to 
“YES”,press “OK” to reset the WEATHER TEMP. SET. 
 
 

 

 

Controller

10

Owner's & Installation manual

PRESET TEMPERATURE

SCROLL 

ON/OFF 

ECO

MODE

PRESET
TEMP.

COOL  MODE  LOW   TEMP

HEAT  MODE  LOW   TEMP. 

ON 

OFF 

WEATHER
TEMP.SET

ON/OFF 

PRESET TEMPERATURE

PRESET
TEMP.

OFF 

WEATHER
TEMP.SET

ECO

MODE

 
 
 

HEAT MODE LOW TEMP. 

ON/OFF

ON/OFF 

 
 

ECO MODE SET  TYPE:

ECO    MODE SET

SCROLL

CONFIRM

OK 

1 2 3 

5 6 7 8 

Use '

''

''

''to scroll .Press ''OK'' to select. 

 

 
 
 
 
 

 ECO MODE SET have two kinds of curves :1.the curve of the high 

temperature setting for heating,2.the curve of the low temperature 
setting for heating, 
It only have the curve of the high temperature setting for heating, if  
the high temperature is set for heating.
It only have the curve of the low temperature setting for heating, if  
the low temperature is set for heating.

 See FOR SERVICEMAN> 

HEAT MODE SETTING in installation& ower's  manual.

 The desired temperature (T1S) can

t be adjusted, when the ECO 

mode is ON.

 You can selet the low or hige temperature setting for heating to see 

the 

Table 5~6

.

 If HEAT MODE is ON and ECO TIMER is OFF,the unit run ECO 

mode all the time.

 If HEAT MODE is ON and ECO TIMER is ON,the unit run ECO 

mode according to the start time and end time.

INFORMATION

Summary of Contents for AEROTHERM V17

Page 1: ...ima com Thank you very much for purchasing our product Before using your unit please read this manual carefully and keep it for future reference Controller owner s and installation manual SO30170 to S...

Page 2: ...in electrocution CAUTION Indicates a situation that could result in minor or moderate injury WARNING Indicates a situation that could result in death or serious injury INFORMATION Indicates useful tip...

Page 3: ...cured Silent mode is activated The disinfect function is activated Holiday away home is activated Backup heater is activated The compressor is activated Desired temp DHW mode the desired temp will not...

Page 4: ...FHLn SV2 UI SV1 TANK 55 C 27 SET C ON ON DHW ROOM 21 55 08 08 2015 SAT Home page 1 If the WATER FLOW TEMP is set YES and ROOM TEMP is set NON See FOR SERVICEMAN TEMPERATURE TYPE SETTING on installatio...

Page 5: ...ION PAGE 21 55 08 08 2015 SAT ON ROOM 21 55 08 08 2015 SAT ON MAIN MAIN PAGE ADDITION PAGE TANK C 12 SET C ON ON DHW MAIN 21 55 08 08 2015 SAT 55 SET C 24 21 55 08 08 2015 SAT ON ROOM SV1 FHL1 FHL2 FH...

Page 6: ...controls The ON OFF of the unit can be controlled by the interface if the ROOM THERMOSTAT is NON see ROOM THERMOSTAT SETTING on INSTALLATION OWNER S MANUAL ON TANK 55 C SET C OFF DHW MAIN 21 55 08 08...

Page 7: ...tat CONFIRM OK 2 When the cursor is on DHW operation mode Press ON OFF key to turn on off the DHW mode TANK C 12 SET C ON ON DHW MAIN 21 55 08 08 2015 SAT A 55 TANK C 12 SET C OFF ON DHW MAIN 21 55 08...

Page 8: ...ration mode is Always heat mode heat Always cool mode cool auto A Automatically changed by the software based on the outdoor temperature and depending on installer settings also the indoor temperature...

Page 9: ...red the water flow temperature auto maticly depending on the outside air temperature During the warmer weather the demand for space heating is reduced To prevent the heat pump from producing excessing...

Page 10: ...2 3 5 6 7 8 4 6 2 3 ECO MODE Use ECO MODE is used to save energy during the night If ECO mode is activated is displayed on the home page Go to MENU PRESET TEMPERATURE ECO MODE Press OK The following p...

Page 11: ...ration in DHW mode 6 3 2 Fast DHW 6 3 3 TANK HEATER Go to MENU DOMESTIC HOT WATER TANK HEATER Press OK The tank heater function is used to force the tank heater to heat the water in tank In the same s...

Page 12: ...STIC HOT WATER DHW SCROLL 1 2 NO START 06 00 00 00 00 00 2 3 00 00 4 1 NO START 00 00 00 00 00 00 6 7 00 00 8 5 DIS INFECT FAST DHW TANK HEATER DHW PUMP DOMESTIC HOT WATER DHW SCROLL 2 2 NO START 06 0...

Page 13: ...ys at least when we want to enable WEEKLY SCHEDULE function INFORMATION If the weekly schedule function is on the timer is off the later setting is effective If the Timer is activated is displayed on...

Page 14: ...M page to the MAIN page The TIMER or WEEKLY SCHEDULE is invalid if ROOM THERMOSTAT is effect INFORMATION The ECO or COMFORT MODE has the highest priority the TIMER or WEEKLY SCHEDULE has the second pr...

Page 15: ...o MENU OPTIONS SILENT MODE Press OK The following page will appear Use ON OFF to select ON or OFF Description If CURRENT STATE is OFF SILENT MODE is invalid When you select SILENT LEVEL and press OK o...

Page 16: ...15 08 2015 17 08 2015 ENTER SILENT MODE SCROLL ENTER OK CURRENT STATE FROM UNTIL TIMER HOLIDAY AWAY HOLIDAY HOME BACKUP HEATER OPTIONS SILENT MODE SCROLL HOLIDAY AWAY HOLIDAY HOME BACKUP HEATER OPTION...

Page 17: ...0 ERROR CODE SCROLL PARAMETER SERVICE CALL SERVICE INFORMATION DISPLAY SERVICE CALL E2 E2 E2 E2 14 10 01 08 2015 14 00 01 08 2015 13 50 01 08 2015 13 20 01 08 2015 SCROLL ENTER OK PARAMETER ERROR CODE...

Page 18: ...will be turned off 6 9 3 How To Exit FOR SERVICEMAN OPERATION PARAMETER P2 COMP PRESSURE2 kPa POWER CONSUMPTION OKWH SCROLL 5 5 OPERATION PARAMETER T1 WATER FLOW TEMP 25 C 30 C T2 PLATE F OUT TEMP 45...

Page 19: ...TE FROM UNTIL SCHEDULE DISPLAY LANGUAGE BACKLIGHT BUZZER SCREEN LOCK TIME TIME CURRENT TIME CURRENT DAY DOMESTIC HOT WATER DHW DISINFECT FAST DHW TANK HEATER DHW PUMP OPTIONS SILENT MODE HOLIDAY AWAY...

Page 20: ...1_AHS_OFF t_AHS_DELAY 12 2 PREHEATING FOR FLOOR FLOW SET TEMPERATURE RETURN TEMPERATURE PREHEATING TIME OPERATE PREHEATING FOR FLOOR 12 3 FLOOR DRYING UP DRYING UP TIME HIGE TEMP TIME DRYING DOWN TIME...

Page 21: ...S 39 38 38 37 37 37 36 36 35 35 34 34 33 33 32 32 31 31 30 30 30 7 T1S 40 40 39 39 38 37 37 36 36 35 35 34 34 33 33 32 32 31 31 30 30 8 T1S 41 41 40 40 39 38 38 37 37 36 35 35 34 34 33 32 32 31 31 30...

Page 22: ...cooling Table 4 The environment temperature curve of the high temperature setting for cooling 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7 7 7 6 7 7 7 7...

Page 23: ...5 34 34 33 33 32 32 31 31 30 30 30 30 30 30 30 30 30 30 30 8 37 36 35 35 34 34 33 33 32 31 31 31 30 30 30 30 30 30 30 30 Table6 The environment temperature curve of the high temperature setting for EC...

Page 24: ...he remote signal of the controller to be disturbed refer to the right figure 8 2 1 Installation location 2 2 Preparation before installation 1 2 3 4 5 1 3 2 1 2 GB950 86 M4X20 M4X25 GB823 88 6 3 No Na...

Page 25: ...el after installation and then install the controller back to the bottom cover 6 Over fasten the lead to deforma tion of back cover outlet P P PP B C Wiring hole x o b n a i c i r t c e l Diameter W P...

Page 26: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...