Muncie DT12 PTO Installation Instructions Download Page 2

 5. Install the adapter on the transmission using 

the thicker gasket (0.020") included with the 

installation kit.

  

    Torque cap screws (M12x30)  

to 50 ft.lbs.

    Measure backlash between the adapter and 

transmission gear. Backlash should measure  

between 0.006"-0.012".

    Adjust as necessary using the second gasket. 

Additional gaskets are available from Muncie 

Power, if necessary.

 6. Install PTO (See IN84-03 for installation 

instructions).

    Use edge molded gasket between the adapter 

and the PTO, or between the adapter and any 

spacer plates required for PTO installation. (Not 

required to measure backlash if no spacers are 

used between the PTO and the adapter.)

    It is critical that the edge molded gasket be 

used against the adapter! Failure to do so may 

result in leaking!

201 East Jackson Street • Muncie, Indiana 47305

800-367-7867 • Fax 765-284-6991 • [email protected] • www.munciepower.com

Specifications are subject to change without notice. Visit www.munciepower.com 

for warranties and literature. All rights reserved. © Muncie Power Products, Inc. (2021)

A Member of the Interpump Group

IN20-07 (Rev. 02-21)

Gasket

0.010" - 13M35151

0.020" - 13M35152

(Helical gear should

be on right side)

Torque to 50 ft.lbs. (8 places)

Edge molded gasket P/N 13T65089

Used between adapter and spacer

Spacer (2 used on 828S-U6815,  

1 used on 828S-U6819)

TG Series, 82 Series 05 - 13 ratios

Setting backlash between PTO and adapter NOT required

Edge molded gasket - P/N 13T65089 

Measuring backlash not required

82 Series 15 and 19 ratios only

Backlash must be set between PTO and adapter!

Paper gasket

Reviews: