6. Fix the main panel of the MONO-S to the rear panel (back plate) with two (3 x 22 CSK) screws (supplied),
after making sure the connectors meet perfectly.
7. Fix the MONO-S cover to the main panel with the two (3 x 6 CSK) security screws using the Allen security
key (supplied).
Cautionary Notes
1. U
se a separate power supply when connecting a door strike. If the door strike and MONO-S are
connected to the same power supply the power consumption of the door strike may effect its proper
functioning.
2.
Maximum recommended cable length between 2 MONO-S keypads is 100 metres and between
power supply and the MONO-S is 50 metres.
Make sure the tamper switch on the rear panel of the MONO-S keypad is making direct contact with the wall.
2.2 Wiring instructions
Connections on the MONO-S
2.3 Bus Connection
Note: Power supply should be 12V DC and the distance between the MONO-S keypad and the host
should not exceed 100 meters.
2.3.1 CODIX format
Connect the communication bus lines (GND, DATA and +9V) of the MONO-S keypad to the
corresponding connectors of the host system.
2.0 Mounting and Wiring Instructions
4
JUMPER
GND
GND
+9V
+9V
DATA
EX5/EX7 / MONO / DUO
8 9
7
4 5 6
1 2
3
0 B
A
Max 200m
GND
GND
+9V
+9V
DATA