AT#OMADMSVPORT?

Read OMA-DM server

AT#OMADMPROXY=<port#>,<URL>

Set OMA-DM proxy server port/URL (default
http://oma.ssprov.sprint.com:80)

AT#OMADLPROXY=<port#>,<URL>

Set OMA-DL Proxy DL Server Port URL (default
http://oma.ssprov.sprint.com:80)

AT#OMADMCEN=<onoff>

Set OMA-DM Client feature; Disable=0, Enable=1

Important:

Never deploy devices with AT#OMADMCEN=0. Many

OMA commands result in error if OMADMCEN is set to 0.

AT#OMADMCEN?

Query the current OMA-DM client status

AT#OMADMCEN=?

Query OMA-DM available values

AT+OMADM=(onoff)

Set OMA-DM Client Initiated Device Configuration; Disable=0, Enable=1,
Initiate=2

AT+OMADM=?

Query OMA-DM Client Initiated Device setting

AT+PRL=<onoff>

Set OMA-DM CIPRL Session; Disable=0, Enable=1, Initiate=2

AT+PRL=?

Query OMA-DM CIPRL Session setting

AT+FUMO=

Set OMA-DM FUMO enable parameter; Disable=0, Enable=1, Initiate=2

AT+FUMO=?

Query OMA-DM FUMO parameter

AT#HFA

Initiate Sprint Hands Free Activation (HFA)

AT#HFACANCEL

Cancel Sprint Hands Free Activation (HFA) DM Session

AT$RTN=xxxxxx

HFA reset (after device reboot HFA will occur) xxxxxx= SPC or MSL.

Note:

May not work with all firmware versions.

AT#SPRTN=xxxxxx

After device reboot HFA will occur xxxxxx= SPC or MSL

AT#DCCANCEL

Cancel Device Configuration (DC) Session

AT#PRLCANCEL

Cancel Preferred Roaming List (PRL) Session

AT$PRL?

Query Preferred Roaming List (PRL) ID #

AT#FUMOCANCEL

Cancel Firmware Update Management Object (FUMO) session.

Sprint Successful Indications

Typical Successful HFA Session
Indications

Alternate Successful HFA Session
Indications

Typical Successful FUMO Session
Indications With firmware update

#900

#900

#907

#904

#904

#921

#919

#914

#921: 572 Bytes

#905

#905

#920:23

#909

#910

#920:100

#907

#900

New firmware installing

Summary of Contents for MultiConnect Dragonfly MTQ-EV3 Series

Page 1: ...MultiConnect Dragonfly TM MTQ EV3 Device Guide...

Page 2: ...NABLE ATTORNEYS FEES RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR COMMUNICATIONS NETWORK USING THE PRODUCTS The MultiTech products and the final application of the MultiTech products should be...

Page 3: ...V3 B01 External Pin Alternate Function Mapping 13 Processor Pin Information B01 models only 16 Communications Flow 19 Processor Model B01 19 No Processor Model B02 19 Electrical Characteristics 19 Ope...

Page 4: ...on 33 Handling Precautions 33 Radio Frequency RF Safety 33 S curit relative aux appareils radiofr quence RF 33 General Safety 34 Interference with Pacemakers and Other Medical Devices 34 Potential int...

Page 5: ...Equipment Statement 42 WEEE Directive 42 Instructions for Disposal of WEEE by Users in the European Union 42 REACH Statement 42 Registration of Substances 42 Substances of Very High Concern SVHC 42 R...

Page 6: ...formation S000627 Universal Developer Kit 2 0 Developer Guide Provides information on using the developer board with the MTQ S000610 USB Driver Installation Guide Provides steps for installing EV DO C...

Page 7: ...CHAPTER 2 MECHANICAL DRAWINGS MultiConnect Dragonfly TM MTQ EV3 Device Guide 7 Chapter 2 Chapter 2 Mechanical Drawings Processor Model B01...

Page 8: ...CHAPTER 2 MECHANICAL DRAWINGS 8 MultiConnect Dragonfly TM MTQ EV3 Device Guide No Processor Model B02...

Page 9: ...up to 1 8 Mbps Interface USB Interface USB 2 0 high speed1 UART B01 models Full UART to processor then RX TX RTS CTS only between the processor and radio B02 Models Full UART Physical Description Wei...

Page 10: ...designed for single cell Li Ion Li Poly technology Acceptability of the battery charge circuit for charging specific batteries cells is to be determined in the end product 3 Radio performance may be...

Page 11: ...er Input Main Power 9 IO_00 I 0 7V O 0 3V I O General Purpose I O from ST Microcontroller STM 32F411 10 IO_01 11 IO_02 12 IO_03 13 GND GND GND Ground 14 IO_04 I 0 7V O 0 3V I O General Purpose I O fro...

Page 12: ...tput MTQ xx B02 Pin Definitions Pin Signal Name Logic Level Voltage1 Max Voltage In Out Description 1 N C 2 N C 3 N C 4 PWR_GOOD 0 VCC IN O Open drain power good status indication output 5 GND GND GND...

Page 13: ...T 0 3V I Radio reset 36 GND GND GND Ground 37 GND 38 N C 39 N C 40 N C Note For B02 models only Pins 14 15 16 and 27 are part of the SPI interface These pins are inputs If you do not use them connect...

Page 14: ...PB_8 17 IO_07 D2 PB_15 18 IO_08 A0 PC_2 19 IO_09 A3 PB_0 20 IO_10 A1 PC_0 21 IO_11 A4 PC_1 22 IO_12 A2 PC_4 23 IO_13 D9 PB_13 24 IO_14 A5 PC_9 25 IO_15 SDA SRDY D14 PB_9 26 IO_16 MISO D12 PA_6 27 IO_...

Page 15: ...RTS TIM2_CH2 TIM5_CH2 EVENTOUT ADC1_1 14 SPI1_MOSI I2C1_SMBA TIM3_CH2 SDIO_D3 EVENTOUT 15 SPI1_SCK TIM2_CH1 TIM2_ET EVENTOUT ADC1_5 16 I2C1_SCL I2C3_SDA TIM4_CH3 TIM10_CH1 EVENTOUT 17 SPI2_MOSI TIM1_C...

Page 16: ...OUT ADC1_3 38 SPI1_SCK USART1_RX TIM2_CH2 EVENTOUT 39 EVENTOUT 40 I2C1_SDA USART1_RX TIM4_CH2 SDIO_D0 EVENTOUT Processor Pin Information B01 models only Note Diagram from the STMicro 32F411 datasheet...

Page 17: ...D 18 VSS_4 Power VDD3_3 19 VDD_4 Power SPI SS1 20 PA4 SPI1 Select IO_05 SCK 21 PA5 SPI1 Clock GPIO IO_16 MISO SDIO_CM D 22 PA6 SPI1 MSIO SDIO_CMD GPIO IO_01 DCD 23 PA7 GPIO IO_12 24 PC4 GPIO Analog ca...

Page 18: ...S_DP 45 PA12 USB J_TMS SWDIO 46 PA13 JTAG 47 VCAP_2 VSS Power VDD3_3 48 VDD_2 Power J_TCK SWCLK 49 PA14 JTAG J_TDI C_MON 50 PA15 JTAG SPI SCK 51 PC10 EPROM SPI3_SCK SPI MISO 52 PC11 EPROM SPI3_MISO SP...

Page 19: ...itch between a connection to the radio or a connection to the processor The USB selection is controlled via programming on the processor There is no USB between the radio and the processor No Processo...

Page 20: ...high level voltage for an I O pin VDD 1 3 1 Output low level voltage for an I O pin IIO 6 mA 0 4 1 Output high level voltage for an I O pin VDD 0 4 1 Output low level voltage for an I O pin IIO 4 mA...

Page 21: ...ll Box Connection No Data Amps AVG Measured Current Amps at Max Power1 Peak TX 2 Amplitude Current Amps Total Inrush Charge3 Measured in Millicoulombs mC 5 Volts USB US Cellular 800Mhz 0 006 N A 0 664...

Page 22: ...uring a CDMA connection transmitting data at max power 3 Inrush Charge The total inrush charge at power on Waveforms USB only inrush current of 3 85mC with a duration of 40 7 ms USB Cable Recommendati...

Page 23: ...OFF low longer than 1 second causes a controlled disconnect from the network and then turns the radio off The radio stays off as long as 3G_ONOFF is held low Due to the network disconnect shutoff can...

Page 24: ...g CFUN commands then reset the device via the PC13 3G_ONOFF toggle low to high to bring the radio out of CFUN sleep mode Link Status LED LED 2 Signal Link Status LED OFF Device off ON Continuously lit...

Page 25: ...LTE2 1HRA 1 ANLTE2 10HRA 10 ANLTE2 50HRA 50 Antenna Specifications Category Description Frequency Range 069 0 96GHz 1 71 2 17GHz 2 3GHz 2 69GHz Impedance 50 Ohms VSWR VSWR should not exceed 3 1 at any...

Page 26: ...max LTE B13 B17 Impedance 50 ohms unbalanced Radiation Omni directional Polarization Linear SMA to U FL Cable Use an SMA to U FL cable to connect your device to an antenna Part numbers if ordering th...

Page 27: ...ith respect to RF exposure compliance The antenna s used for this transmitter must be installed to provide a separation distance of at least 20 cm from all persons and must not be collocated or operat...

Page 28: ...on of the approved device circuit board or antenna system All applications interacting with Sprint approved MultiTech devices must be written in a manner where they do not interfere interrupt the Spri...

Page 29: ...error 912 HFA Error unreachable server 913 HFA Error network error 914 HFA Done HFA success 922 HFA Done No profile received 923 HFA Error ETC 924 HFA Cancelled DREL Data session release Sprint Networ...

Page 30: ...FUMO Firmware size get from the OMA DM server byte 929 200 FUMO Firmware Update Success 929 402 FUMO Firmware corrupted CRC error 929 403 FUMO Firmware package mismatch 929 404 FUMO Firmware signatur...

Page 31: ...1 Initiate 2 AT PRL Query OMA DM CIPRL Session setting AT FUMO Set OMA DM FUMO enable parameter Disable 0 Enable 1 Initiate 2 AT FUMO Query OMA DM FUMO parameter AT HFA Initiate Sprint Hands Free Act...

Page 32: ...Alternate Successful HFA Session Indications Typical Successful FUMO Session Indications With firmware update 916 900 900 930 907 929 200 Typical Successful FUMO Session Indications without Firmware...

Page 33: ...vices to the offender legal action or both Switch OFF your wireless device when around gasoline or diesel fuel pumps and before filling your vehicle with fuel Switch OFF your wireless device in hospit...

Page 34: ...measure EMI of implanted cardiac pacemakers and defibrillators from cellular devices This test method is part of the Association for the Advancement of Medical Instrumentation AAMI standard This stand...

Page 35: ...ravel cards or other magnetic media The information contained on discs or cards may be affected by the device Using accessories such as antennas that MultiTech has not authorized or that are not compl...

Page 36: ...Uses RTS CTS flow control on the serial connection to the radio and on the external serial connection Enables RTS CTS flow control on terminal emulators used with the AT pass through firmware MTSAS Li...

Page 37: ...rted mbed Handbook http developer mbed org handbook Homepage Serial Flash Datasheet https www micron com media documents products data sheet nor flash serial nor m25p m25p16 pdf Additional Information...

Page 38: ...model identification allows the carrier to verify the modem as one of its approved models This information is located on the modem s label below the bar code Example Labels Note Actual labels vary de...

Page 39: ...e separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV t...

Page 40: ...mat riel brouilleur This device complies with Industry Canada license exempt RSS standard s The operation is permitted for the following two conditions 1 the device may not cause interference and 2 t...

Page 41: ...dustrie Canada Avis L IES indice d quivalence de la sonnerie attribu chaque terminal fournit une indication du nombre maximal de terminaux pouvant tre connect s une interface t l phonique La terminais...

Page 42: ...collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources and ensure that it is recycled in a manner that protects human health and the environme...

Page 43: ...edded products comply with the chemical concentration limitations set forth in the directive 2011 65 EU of the European Parliament Restriction of the use of certain Hazardous Substances in electrical...

Page 44: ...romi nated Biphenyl PBB Polybrominat ed Diphenyl Ether PBDE Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O...

Page 45: ...ards in Chinese MII EIP 39 RoHS Multi Tech Systems Inc TS HS PB Hg CD CR6 PBB PBDE O O O O O O X O O O O O X O O O O O O O O O O O O O O O O O ICs O O O O O O O O O O O O X O O O O O O O O O O O O O O...

Page 46: ...on 6 E electrical characteristics 19 F FCC grant notes 27 FCC Notice Class B 39 firmware 36 G GPS 35 H hazardous substances 43 host labeling 27 I Industrie Canada 40 Industry Canada 40 Class B 40 inte...

Page 47: ...TQ EV3 B01 21 MTQ EV3 B02 22 processor pins 16 R radio frequency interference 33 RoHS 43 S safety modem 34 RF interference 33 shutdown 23 sleep mode 23 SMA to U FL cable 26 specifications 9 Sprint 28...

Reviews: