CONFIGURING AND COMMUNICATING WITH YOUR DEVICE

AT#FRWL=1,"###.##.###.#","###.##.###.#" where ###.##.###.# represents the IP range. For example:
AT#FRWL=1,"204.26.122.1","204.26.122.255"

6.

Set connection ID 1 for UDP listening mode on port 7000.

Enter:

AT#SLUDP=1,1,7000

The device responds with and unsolicited indication that a host is trying to connect to connection ID 1 on
port 7000.
SRING: 1

7.

Accept incoming connection ID 1

Enter:

AT#SA=1

The device indicates a client successfully established a listener connection.
CONNECT
You can send and receive data.

Exit Data Mode and Close Connection

To exit data mode and close the socket:

Enter the escape sequence: +++

To close Socket 1, enter: AT#SH=1

The device responds with OK.

To close the data connection, enter:AT#SGACT=1,0

The device responds with OK.

Transferring FTP File to FTP Server

To connect to FTP server and upload files:

1.

Check signal strength.

Enter:
AT+CSQ

2.

Activate context one

Enter:
AT#SGACT=1,1

3.

Set FTP operations timeout to 10 seconds

Enter:
AT#FTPTO=1000

4.

Configure FTP server IP address with username and password.

Enter:
AT#FTPOPEN="###.##.###.#","username","password",0 where ###.##.###.# is the IP address and the
username and password for the FTP server.

5.

Configure file transfer type.

Enter:

28

MultiConnect

®

Cell MTC-H5 User Guide

Summary of Contents for MultiConnect Cell MTC-H5

Page 1: ...MultiConnect Cell MTC H5 User Guide...

Page 2: ...on or communications systems control equipment for nuclear facilities or missile nuclear biological or chemical weapons or other military applications Restricted Applications Use of the products in su...

Page 3: ...nada 14 Avertissements relatifs l installation et aux emplacements dangereux 14 ATEX Europe only 14 Hazardous Location Special Considerations 14 Antenna 15 Installing and Using the Device 16 Installin...

Page 4: ...ver 28 Downloading File from FTP Server 29 Reading Writing and Deleting Messages 30 Reading Text Messages 30 Sending Text Messages 30 Deleting Messages 31 Regulatory Information 32 Industry Canada Cla...

Page 5: ...open interfaces Documentation The following documentation is available on the Multi Tech Installation Resources website at www multitech com setup product go Document Description MultiConnect Cell Us...

Page 6: ...lished LS Link Status Not lit There is no power to the cellular radio Continuously Powered and connected but not transmitting or receiving lit Slow blink Powered and searching for a connection Fast bl...

Page 7: ...formance HSPA GPRS EDGE Cell 850 824 894 MHz Frequency Bands Cell 900 880 960 MHz Cell 1800 1710 1880 MHz Cell 1900 1850 1990 MHz Radio Cellular Telit HE910 D Speed Packet Data Up to 7 2 Mbps downlink...

Page 8: ...A C22 2 No 213 EN 60079 0 2012 A11 2013 EN 60079 15 2010 Network Compliance GCF PTCRB Warranty Two years 1 Device has been tested up to 85 C UL Recognized 40 C limited by AC power supply UL Recognized...

Page 9: ...n Abbreviation Description In Out 3 TX Transmit I 4 DTR Data Terminal Ready I 5 GND Ground 6 DSR Data Set Ready O 7 RTS Request to Send I 8 CTS Clear to Send O 9 RI Ring Indicator O MultiConnect Cell...

Page 10: ...p Mode Cellular call box Average TX Pulse AVG Total inrush Current amps connection no measured current Amplitude charge measured data amps amps at Current amps in MilliCoulombs maximum power mC 7 volt...

Page 11: ...PRODUCT OVERVIEW Dimensions Serial MultiConnect Cell MTC H5 User Guide 11...

Page 12: ...PRODUCT OVERVIEW USB 12 MultiConnect Cell MTC H5 User Guide...

Page 13: ...cy energy RF from cellular devices can interact with some electronic devices This is electromagnetic interference EMI The FDA helped develop a detailed test method to measure EMI of implanted cardiac...

Page 14: ...fournira uniquement un acc s au modem gr ce une cl ou un outils sp cifique 2 CET QUIPEMENT EST ADAPT EXCLUSIVEMENT POUR UNE UTILISATION EN ZONE DE CLASSE I DIVISION 2 GROUPES A B C ET D OU EN ZONE NON...

Page 15: ...for use with this unit meets the requirements for mobile operating configurations and for fixed mounted operations as defined in 2 1091 and 1 1307 of the FCC rules for satisfying RF exposure complianc...

Page 16: ...power mode if batteries are used to power the device For example you might want to use your device outdoors and have it powered by a solar charged battery By using low power you can save time and mon...

Page 17: ...mputer chassis Use USB 3 0 ports if available These ports are typically rated for more current You can re order the USB cable through Multi Tech The part number is CA USB A MINI B 3 Installing a SIM C...

Page 18: ...he downlink connection cell tower to mobile It has no effect on the uplink mobile to cell tower Antenna diversity is useful in environments where the signal arrives at the device after bouncing off or...

Page 19: ...ds of operation Maximum Radiated Gain 3 dBi Radiation Omni directional Polarization Linear Vertical Antenna The antenna intended for use with this unit meets the requirements for mobile operating conf...

Page 20: ...network To find activation steps for your device 1 Go to http www multitech com support 2 Select your device 3 Scroll to Activation and click Download Device Phone Number Every device has a unique ph...

Page 21: ...pppd and chat programs are also required pppd needs two scripts the first script performs the environment setting and calls the second script which is used by the chat program For creating a PPP conne...

Page 22: ...omp nopcomp noaccomp For sanity keep a lock on the serial line lock Show password in debug messages show password This script calls the option connect using the script hsdpa_connect for example bin sh...

Page 23: ...ate the connection to the cellular TCP IP network This provides Internet access for sending and receiving email creating TCP UDP Sockets or putting and getting files from an FTP server Before You Begi...

Page 24: ...eceived signal strength indication 0 113 dBm or less 1 111 dBm 2 30 109 dBm 53 dBm 2 dBm per step 31 51 dBm or greater 99 Not known or not detectable ber Bit error rate in percent 0 Less than 0 2 1 0...

Page 25: ...evice responds with the IP Address the cellular provider assigned to the device on connection followed by OK For example SGACT 25 194 185 116 OK 2 Create Client Connection to TCP Server on Port 500 En...

Page 26: ...h and unsolicited indication that a host is trying to connect to connection ID 1 on port 7000 SRING 1 7 Accept incoming connection ID 1 Enter AT SA 1 The device indicates a client successfully establi...

Page 27: ...t connection Exit Data Mode and Close Connection To exit data mode and close the socket Enter the escape sequence To close Socket 1 enter AT SH 1 The device responds with OK To close the data connecti...

Page 28: ...a Exit Data Mode and Close Connection To exit data mode and close the socket Enter the escape sequence To close Socket 1 enter AT SH 1 The device responds with OK To close the data connection enter AT...

Page 29: ...ction Enter AT FTPCLOSE 3 Close the PPP data connection Enter AT SGACT 1 0 The device responds with OK Downloading File from FTP Server To connect to an FTP server and download files 1 Check signal st...

Page 30: ...osing the FTP Data Connection When you finish sending the file 1 Close the FTP connection Enter AT FTPCLOSE 2 Close the PPP data connection Enter AT SGACT 1 0 The device responds with OK Reading Writi...

Page 31: ...select storage and is the delflag option Enter 0 Deletes message in the specified index 1 Deletes all read messages Leaves unread messages and stored device originated messages 2 Deletes all read and...

Page 32: ...ust accept any interference including interference that may cause undesired operation of the device Cet appareil est conforme avec Industrie Canada RSS exemptes de licence standard s et la partie 15 d...

Page 33: ...ction retry algorithm If you fail to do so Aeris might block network access for your devices After your devices reach the end of their commercial lifespan you must remove them from the Aeris network T...

Page 34: ...These MultiTech products do not contain the following banned chemicals1 Lead Pb 1000 PPM Mercury Hg 1000 PPM Hexavalent Chromium Cr 6 1000 PPM Cadmium Cd 100 PPM Polybrominated Biphenyl PBB 1000 PPM P...

Page 35: ...rt of a formal quality system and will be made available upon request Waste Electrical and Electronic Equipment Statement WEEE Directive The WEEE Directive places an obligation on EU based manufacture...

Page 36: ...r PBDE PBB Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O O Diodes Transistors O O O O O O Oscillat...

Page 37: ...s Inc TS HS PB Hg CD CR6 PBB PBDE O O O O O O X O O O O O X O O O O O O O O O O O O O O O O O ICs O O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O LEDs O...

Reviews: