SPECIFICATIONS
SocketModem
®
Cell MTSMC-MNG2 Device Guide
11
Category
Description
Input Voltage
3.3–5 VDC
Certifications and Compliance
EMC and Radio
Compliance
RED
RCM
Safety Compliance IEC 60950-1 2nd ED
Approvals
PTCRB, AT&T, Verizon, RED
Powering Down Your Device
CAUTION:
Failing to properly power down the device before removing power may corrupt your device's file
system.
To properly power down your device, use the following sequence :
1.
Issue the AT#SHDN command.
2.
Wait 30 seconds.
3.
Power off or disconnect power.
Note:
If you send AT#SHDN and do not remove power, the radio restarts after 60 seconds.
UART DC Electrical Characteristics
Units:
Volts
Applies to the following pins:
Pin
Signal Name
Pin
Signal Name
J33
-RTS
J37
-DSR
J34
-RXD
J38
-CTS
J35
-TXD
J39
-DCD
J36
-RI
J40
-DTR
Parameter
Minimum
Maximum
3.3 Volt Powered
Input Low Level
0
0.55
Input High Level
1.5
3.3
Output Low Level
0
0.55
Output High Level
2.35
3.3
5 Volt Powered
Input Low Level
0
0.8
Input High Level
2.3
5