SPECIFICATIONS AND RELATED INFORMATION
Conduit
®
IP67 Series 200 Base Station MTCDTIP2 Hardware Guide
11
Reset Button
You need:
A slim screwdriver (1 or 2mm), paperclip, or similar thin object that can fit into the reset hole.
The following is the default condition for the RESET button on the device. You can program a change to the
behavior of the button if needed. To reset the device:
1.
Remove the clear plastic cap.
2.
Find the hole labeled RESET. The reset button is recessed.
3.
Use the screwdriver or paperclip to press and release the RESET button as follows:
To reboot, press RESET for less than 3 seconds.
To reboot and restore user-defined defaults (if previously set), press RESET for 3 to 29 seconds.
To reboot, restore factory settings, and erase user-defined defaults, press RESET for 30 seconds or
longer.
4.
Reattach the plastic cover and tighten to 10.5 lbf.in (12 kgf.cm).
Note:
The device reboots when restoring settings.
Power Measurements
Cellular Power Measurements
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source
when determining product load.
Maximum Power:
The continuous current during maximum data rate with the radio
transmitter/LoRa at maximum power.
Tx Pulse:
The average peak current during HSDPA/LTE connection with LoRa at Max power.
Inrush Charge:
The total inrush charge at power on.
Voltage
Power Down
Mode via
Radio
Command
Cellular Call
Box
Connection
(No Data)
Average
Measured
Current at
Max Power
TS Pulse
Average Peak
Current for
HSDPA/ LTE
Total Inrush
Charge
measured in
MilliCoulombs
Total Inrush
Charge
DURATION
during
Powerup
(INRUSH
Duration)
LTE BAND 7 (2535 Mhz)
37VDC POE
51 mA
53 mA
212 mA
388 mA
1.16 mC
8.98 mS
57VDC POE
41 mA
42 mA
151 mA
276 mA
1.06 mC
8.0 mS
WCDMA Band 1 (1922.4 MHz)
37VDC POE
47 mA
51 mA
218 mA
380 mA
1.16 mC
8.98 mS