SPECIFICATIONS AND HARDWARE INFORMATION
10
Conduit
®
AP MTCAP2-L4E1-868-002 and MTCAP2-868-002 User Guide
Resetting the Device
You need:
A pin, paperclip, or similar thin object that can fit into the reset hole
To reset the device:
1.
Find the hole labeled RESET. The reset button is recessed into the case.
2.
Use the pin to press and release the RESET button as follows:
Reset options:
To reboot, press RESET for less than 3 seconds.
To reboot and restore user-defined defaults (if previously set), press RESET for 3 to 29
seconds.
To reboot, restore factory settings, and erase user-defined defaults, press RESET for 30
seconds or longer.
The device restarts in commissioning mode. The system automatically removes all user
accounts.
Enter a new username and password to create your new administrative account. (Refer to
User Accounts
in the appropriate software guide for details on username and password
requirements.)
Note:
The device reboots when restoring settings.
For more information about commissioning mode, consult the mPower Software Guide or mlinux developer resources.
Refer to
Documentation Overview
for details.
Power Measurements
MTCAP-L4E1-868-042L
Note:
Multi-Tech Systems, Inc. recommends that you incorporate a 10% buffer into the power source
when determining product load.
Maximum Power:
The continuous current during maximum data rate with the radio transmitter at
maximum power.
Tx Pulse:
The average peak current during a GSM850 transmission burst period or HSDPA/LTE
connection. The transmission burst duration for GSM850 can vary, depending on what transmission
scheme is being deployed (GPRS Class 8, Class 10, GSM, etc.).
Inrush Charge:
The total inrush charge at power on.
Voltage
Sleep Mode
Current
Cellular Call
Box
Connection
No Data, OR
IDLE Measure,
with no Radio
Average
Measured
Current at
Maximum
Power
TX Pulse Peak
Current for no
radio model
Total Inrush
Charge
Total Inrush
Charge
Duration
5 VDC
N/A
137 mA
452 mA
584 mA
0.962 mC
1.69 mS