![MULTISPAN UTC-4203 Operating Manual Download Page 2](http://html1.mh-extra.com/html/multispan/utc-4203/utc-4203_operating-manual_1855541002.webp)
www.multispanindia.com
Page - 4
UTC-4203
www.multispanindia.com
Page - 3
UTC-4203
SET VALUE
SET POINT 1
SET POINT 2
SET POINT 3
S E T 2
S E T 3
S E T 1
0 1 0 5
0 1 1 0
0 1 0 0
0 1 0 0
Press key for 3 sec to
enter Password parameter
SET
0 0 3 5
PROCESS VALUE
P A S S
Password Message
p I d
T P
PID
TP
ON-OFF
Parameters
Hysteresis
P A R A
P A R A
0 2 0
.
0
0 0 0 4
0 3 0 0
0 0 1 2
0 0 7 5
0 0 0 0
0 0 1 5
0 0 0 6
0 0 0 6
0 0 0 6
0 0 0 0
0 0 0 3
0 0 0 3
P A R a
0 0 3 7
0 0 0 6
0 0 0 3
0 0 0 3
0 0 0 6
0 0 0 6
0 0 0 6
0 0 0 6
0 0 0 3
0 0 0 3
0 0 0 3
0 0 0 6
P B
P b
I t
C t
D t
m r
C T
T I m 1
T I m 2
T I m 3
m r
H Y S 2
H Y S 3
O n O F
T I m 1
T I m 1
T I m 2
T I m 3
T I m 3
T I m 2
h Y S 2
h Y S 3
h Y S 3
h Y S 1
h Y S 2
Press k
e
y
Press k
e
y
Press k
e
y
Parameters
Parameters
Proportional
Band
Integral
Time
Derivative
Time
Cycle Time
Manual Reset
IF T1MD = SOAK
IF R2MD = OFF
IF R3MD = OFF
or SKPS or SKRG
or E-AL
or E-AL
or E-AL
TO ENTER CONTROL
PARAMETER
SETTING, ENTER “37”
P A S S
Password Message
0 0 5 0
I N P T
Input ( J / K / Pt100 / Pt.1 )
Control Action
HEAT, COOL, H-AL,
L-AL, O-AL, I-AL,AB-L,AB-O,OFF
HEAT, COOL, H-AL,
L-AL,O-AL,I-AL,E-AL,AB-L,AB-O,OFF
SEC/MIN/HOUR
SEC/MIN/HOUR
C T R L
r 1 M D
r 2 M D
T 1 m d
T 2 m d
T 1 u t
T 2 u t
PID/ON-OFF
/TP
OR
P A S S
Password Message
0 0 7 3
J
p I D
H E A T
E- A L
S o h t
a l m t
H o u r
M I N
O n O F
T P
P T
P T
.
1
K
Set Point Low Limit
Set Point High Limit
S L L
S H L
0 0 0 0
0 6 0 0
OFF-SET
O F S T
0 0 0 0
TO ENTER BASIC
CONFIGURATION
SETTING, ENTER “73”
IF R1MD=OFF
IF R2MD=OFF
IF T1MD=OFF
IF T2MD=OFF
IF R1MD = OFF
or E-AL
IF R2MD = OFF
IF T1MD = OFF
Press key
to Save & Exit
IF PID SELECTED
IF ON-OFF SELECTED
IF TP SELECTED
IF T1MD = SOAK
or SKPS or SKRG
Off-set correction
-20.0°C to +20.0°C
-20°C to +20°C
Delay time
1 sec to 999 sec
1 sec to 999 sec
CT
4 sec to 99 sec
4 sec to 99 sec
IT
Hysteresis
0.1°C to 50.0°C
1°C to 50°C
MR
PB
-9.0 to +9.0
2.0 to 20.0
-9 to +9
2 to 20
DT
PB
Sr.
1
2
3
4
5
6
7
8
9
0 to 999.9
0.0 to 999.9
0.0 to 9999
0.0 to 9999
0 to 9999
0 to 9999
Parameter
Range for PT.1 sensor
Range for J, K, PT100
IF T2MD = OFF
IF T3MD = OFF
IF T2MD = OFF
IF R1MD = OFF
HEAT, COOL, H-AL,
L-AL,O-AL,I-AL,E-AL,AB-L,AB-O,OFF
ONDL,SOKT,SKPS,SKRG,ALMT,OFF
ONDL,SOKT,SKPS,SKRG,ALMT,OFF
ONDL,SOKT,SKPS,SKRG,ALMT,OFF
SEC/MIN/HOUR
r 3 M D
T 3 m d
T 3 u t
E- A L
a l m t
M I N
IF R2MD=OFF
IF T2MD=OFF
INDIVIDUAL/RELATIVE
INDIVIDUAL/RELATIVE
s 2 m d
s 3 m d
I n d u
I n d u
Press key
to Save & Exit
Press key
to INPT Setting
Press key
SET
Press key
SET
Press key
SET
Press key
SET
Press key
SET
Press key
SET
Press key
SET
Press key
SET
Press key
SET
Press key
SET
SET
SET
SET
SET
Press key
SET
Press key
SET
Press key
SET
Press key
SET
Press key
SET
IF T2MD = OFF
IF R3MD = OFF
IF T3MD = OFF
or E-AL
Set Point Setting
Basic Configuration
Control Parameter
Factory Setting
FACTORY SETTING
PARAMETER
IT
CT
OFFSET
PB
DT
MR
HYSTERESIS
DELAY TIME
VALUES
0300
15 sec
6 sec
020.0
0075
0°C
0°C
3°C
SR.
2
4
6
1
3
5
7
8
Y E S
ENT
ENT
yes : press key to apply factory set
values as shown in table.
nO : press key to escape
from factory setting.
n O
Press + key
for 3 sec
F C S T
1 2 3 4
1 2 3 4
1) Press Key to go parameter setting.
3) Press Key to save change in setting
4)
Press key for 6 sec to start/stop PID AUTO TUNING
5) Press + key for 3 sec to go to factory setting mode.
SET
SET
ENT
2) Press or key to change value or to select option.
Key Operation
Press key to
Save & Exit
Press key to Save & Exit
PID AUTO-TUNING
Press key for 6 sec to start/stop
PID auto-tuning
PV
SV
1 2 3 4
1 2 3 4