background image

Read complete instructions prior to installation 
and operation of the unit. 

WARNING :

 Risk of electric shock.

SAFETY PRECAUTION

!

       All safety related codifications, symbols and instructions that 
appear in this operating manual or on the equipment must be 
strictly followed to ensure the safety of the operating personnel 
as well as the instrument. 

      If all the equipment is not handled in a manner specified by
 the manufacturer, it might impair the protection provided by the 
equipment.

STATUS LED DESCRIPTION

KEY OPERATION

To enter in parameter setting

For start/stop PID auto tuning

Press 
6 sec

Press 
5 sec

Press 3 sec

+

To go in factory setting mode

PRESS KEY

FUNCTION

OPERATOR MODE

PARAMETER SETTING MODE

To set parameter value

To increment parameter value.

To decrement parameter value.

Set parameter to be save & exit. 

WARNING GUIDELINES

WARNING : Risk of electric shock.

 1. To prevent the risk of electric shock, power supply to the 
    equipment must be kept OFF while doing the wiring 
     arrangement. Do not touch the terminals while power is 
     being supplied.  

 2. To reduce electro magnetic interference, use wire with 
    adequate rating and twists of the same of equal size shall 
     be made with shortest connection.            

 3. Cable used for connection to power source, must have a 
     cross section of 1mm or greater. These wires should have 
     insulations capacity made of at least 1.5kV.      

 4. When extending the thermocouple lead wires, always use
     thermocouple compensation wires for wiring for the RTD
     type, use a wiring material with a small lead resistance
     (5    max per line) and no resistance differentials among 
     three wires should be present.    

 5. A better anti-noise effect can be expected by using 
     standard power supply cable for the instrument.         

Ω

INSTALLATION GUIDELINES

1. This equipment, being built-in-type, normally becomes a 
    part of main control panel and in such case the terminals
    do not remain accessible to the end user after installation 
    and internal wiring.  

2. Do not allow pieces of metal, wire clippings, or fine metallic 
    fillings from installation to enter the product or else it may 
    lead to a safety hazard that may in turn endanger life or 
    cause electrical shock to the operator.      

3. Circuit  breaker or mains switch must be installed between 
    power source and supply terminal to facilitate power ‘ON’ 
    or ‘OFF’ function. However this mains switch or circuit 
    breaker must be installed at convenient place normally 
    accessible to the operator.     

4. Use and store the instrument within the specified ambient 
    temperature and humidity ranges as mentioned in this 
    manual.     

MECHANICAL INSTALLATION GUIDELINES

1. Prepare the panel cutout with proper dimensions as shown 
    above.

   

2. Fit the unit into the panel with the help of clamp given.

   

3. The equipment in its installed state must not come in close 
    proximity to any heating source, caustic vapors, oil steam, 
    or other unwanted process Byproducts.
   

4. Use the specified size of crimp terminal (M3.5 screws) to 
    wire the terminal block. Tightening the screws on the 
    terminal block using the tightening torque of the range of 
    1.2 N.m.

   

5. Do not connect anything to unused terminals. 
   

MAINTENANCE

1. The equipment should be cleaned regularly to avoid blockage 
    of ventilating parts.         

2. Clean the equipment with a clean soft cloth. Do not use 
    isopropyl alcohol or any other cleaning agent.

3. Fusible resistor must not be replaced by operator. 

A - Control Output Indication
B - Auto Tune ON indication
Blinking of Last DP will indicate cooling 
delay time is counting 

A

B

OUT

STATUS LED DESCRIPTION

Page 2

Summary of Contents for UTC-114

Page 1: ...uto Tuning 3 ON OFF control 96 H x 96 W x 52 D mm 100 to 270V AC 50 60Hz 0 C to 55 C UP to 95 RH non condensing IP 65 Front side As per IS IEC 60529 2001 1 Nos 12V DC 30mA DC On Off condition 1C O NO C NC 10A 230V AC 28V DC Reg Load SET INC DEC ENT ON OFF control 92 H x 92 W mm 4VA 230V AC MAX Relay Output SSR Drive Output TECHNICAL SPECIFICATION MECHANICAL INSTALLATION TERMINAL CONNECTION Outline...

Page 2: ... expected by using standard power supply cable for the instrument Ω INSTALLATION GUIDELINES 1 This equipment being built in type normally becomes a part of main control panel and in such case the terminals do not remain accessible to the end user after installation and internal wiring 2 Do not allow pieces of metal wire clippings or fine metallic fillings from installation to enter the product or ...

Page 3: ... SET Press key SET Press key SET SET Press key Press key ENT Press key to save exit DT 75 CT 15 MR 0 pB 20 0 IT 300 ENT Press key to save exit MR pb2 5 CT2 8 0 Proportional Band IF PID Action Selected IP TP Action Selected Integral Time Derivative Time Cycle Timer Manual Reset Proportional Band Cycle Timer Manual Reset SET Press key SET Press key SET Press key PB IT DT CT MR OffSet Hysteresis Dela...

Page 4: ...Press key SET SET SET SET Press key for 5 sec Delay Time 6 Sec 8 SET POINT SETTING Page 4 Specifications are subject to change since development is a continuous process So for more updated operating information and Support Please contact our Helpline 9978991476 9978991474 9978991482 or Email at Ver 200201 service multispanindia com CONTROL FUNCTION RLY OFF RLY ON RLY ON RLY ON RLY OFF RLY OFF Temp...

Reviews: