UTC-114

INPUT SPECIFICATION:

Input Types

Resolution

Indication
Accuracy

Input  

Range

TEMPERATURE CONTROLLER

0 to 600°C, 

0 to 1200°C, 

-99 to 400°C, 

-99.9 to 400.0°C, 

PT-100 

PT.1 

J,K,PT-100 = 1°C
PT.1 = 0.1°C
±1% of FSD ± 1°C

(FSD:- Full Scale Deflection)

DISPLAY AND KEYS:

CONTROL METHOD:

DIMENSION:

OUTPUT SPECIFICATION:

POWER SUPPLY:

ENVIRONMENT CONDITION:

Display

Heating

Size 

Keys

Cooling

Panel Cutout

Power 
Consuption
(VA Rating)

Relative Humidity

Protection Level

(As per request)

Relay

Output Signal

 Supply 
 Voltage

 Operating Temp.

Relay Type

Rating

4 digit, 7 segment, 0.8”Red 

1) PID control with Auto-Tuning

3) ON-OFF control

96 (H) x 96 (W) x 52 (D) mm

100 to 270V AC, 50-60Hz

0°C to 55°C

UP to 95% RH 
(non-condensing)

IP-65 (Front side) As per IS/IEC
60529 : 2001

1 Nos

12V DC, 30mA DC (On-Off condition)

1C/O (NO-C-NC)

10A, 230V AC / 28V DC (Reg. Load)

SET, INC, DEC, ENT

ON-OFF control

92 (H) x 92 (W) mm

4VA @ 230V AC MAX

Relay Output

SSR Drive Output

TECHNICAL SPECIFICATION

MECHANICAL INSTALLATION

TERMINAL CONNECTION

Outline Dimension (mm)

Panel Cutout 
Dimension (mm)

2) (TP) Time Proportional

52

92

92

3

20

18

18

20

20

19

19

19

3-Wire RTD

2-Wire RTD

Thermocouple

Install jumper 
when using 
2 Wire RTD

+

Sensor Input

1

7

8

9

12

13

14

10

11

16

17

18

19

20

15

2

3

4

5

6

NO

C

NC

RTD

T/C

+

-

RELAY

L

N

!

+

-

O/P

S.S.R

 

100 
270V AC

~

 

50/60 HZ
4VA

Made in India

www.multispanindia.com

96

96

UTC 114

ENT

OUT

SET

TUNE

ºC

  234

Page 1

Summary of Contents for UTC-114

Page 1: ...uto Tuning 3 ON OFF control 96 H x 96 W x 52 D mm 100 to 270V AC 50 60Hz 0 C to 55 C UP to 95 RH non condensing IP 65 Front side As per IS IEC 60529 2001 1 Nos 12V DC 30mA DC On Off condition 1C O NO C NC 10A 230V AC 28V DC Reg Load SET INC DEC ENT ON OFF control 92 H x 92 W mm 4VA 230V AC MAX Relay Output SSR Drive Output TECHNICAL SPECIFICATION MECHANICAL INSTALLATION TERMINAL CONNECTION Outline...

Page 2: ... expected by using standard power supply cable for the instrument Ω INSTALLATION GUIDELINES 1 This equipment being built in type normally becomes a part of main control panel and in such case the terminals do not remain accessible to the end user after installation and internal wiring 2 Do not allow pieces of metal wire clippings or fine metallic fillings from installation to enter the product or ...

Page 3: ... SET Press key SET Press key SET SET Press key Press key ENT Press key to save exit DT 75 CT 15 MR 0 pB 20 0 IT 300 ENT Press key to save exit MR pb2 5 CT2 8 0 Proportional Band IF PID Action Selected IP TP Action Selected Integral Time Derivative Time Cycle Timer Manual Reset Proportional Band Cycle Timer Manual Reset SET Press key SET Press key SET Press key PB IT DT CT MR OffSet Hysteresis Dela...

Page 4: ...Press key SET SET SET SET Press key for 5 sec Delay Time 6 Sec 8 SET POINT SETTING Page 4 Specifications are subject to change since development is a continuous process So for more updated operating information and Support Please contact our Helpline 9978991476 9978991474 9978991482 or Email at Ver 200201 service multispanindia com CONTROL FUNCTION RLY OFF RLY ON RLY ON RLY ON RLY OFF RLY OFF Temp...

Reviews: