MULTISPAN PID 2303-1C Manual Download Page 5

Ampere

Set Point-1

Press        key for 4 sec to 
                enter Password  

SET

Process Value

Press      k

e

ENT

  25

 00

set1

 100

pass

  50

100

Set Point Setting

Basic configuration

Set Value

Password Message

If PID Select

 r3md

 HbAL

 SLL

 SHL

 OFST

  ALRM

    H 

   0

  400

  0

Relay 3 Mode

Heater Break Alarm 
Set Point 

Set Point Low Limit

Set Point High Limit

Offset

Case 1 :- If HBA Select

   HBA

   0

.

0

   CS

Hysterisis 3

IF AB-L / High 
selected

HYS3

    3

 r3md

 set3

  ALRM

   MODE

 SET3

 -15

Relay 3 Mode

Set Point 3

Set Point 3

Case 2 :- If CS / HIG / ABL; Select

   RLT

Alarm time

ALRM

    TIME

   5

 I

HB-1

     H

   0

.

0

aBL

PARAMETER SETTING

Alarm

Alarm

Mode

Relative / Individual

time

pass

  73

INPT

J

h

Input ( J / K )

R1MD

HEAT

PID

ONF

HYS1

   3

R2MD

COOL

B

.

TP

ONF

SET2

   5

HYS2

   1

R3MD

ALRM

 I

Case 1 :- If HBA Select

Case 2 :- If CS,HIG,ABL Select

Case 3 :- If INB,ABO Select
Case 4 :- If OFF Select

Relay 1 Mode
Heating

Hysterisis 1

Relay 2 Mode

Coolig

(Blower TP Action/
 ON-OFF)

Set Point 2

Hysterisis 2

Relay 3 Mode
Alarm

High Alarm

If On/Off Select

If R2MD = ON-OFF

/

/

 SLL

   0

Set Point Low Limit

Enter Password 73 

-50 To 0°C

Heater Break Indication 
Set Point 

IND

OPMD

BTH

Output Mode

SSR

RLY

(Both/S.S.R/Relay)

 SHL

Set Point High Limit

  400

 OFST

  0

Offset

Summary of Contents for PID 2303-1C

Page 1: ...p 100 to 250V AC 50 60Hz 0 C to 55 C UP to 95 RH non condensing IP 65 Front side As per IS IEC 60529 2001 Approx 6VA 230V AC TERMINAL CONNECTION MECHANICAL INSTALLATION 1 CT 0 0 to 30 0 A 1 BL TP Blow...

Page 2: ...ine metallic fillings from installation to enter the product or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator 3 Circuit breaker or mains...

Page 3: ...ed or Sensor connection is reversed Over range condition or sensor break no no R2MD ALRM HBAL HBA HbI HIG H ON DT ABL OFF CT INB PB MR CS HTR IT Blower TP Action Hysterisis 2 Absolute Outband Alarm Re...

Page 4: ...0 C Hysteresis 2 4 C to 99 C Pb2 Ct2 Mr2 Alarm Time Set 2 Offset HBAL HBI H 2 Control Mode ON OFF Relay turns ON and remains ON when PV SV Relay turns OFF when PV SV After this there may be overshoot...

Page 5: ...If CS HIG ABL Select RLT Alarm time ALRM TIME 5 H I HB 1 H 0 0 aBL PARAMETER SETTING Alarm Alarm Mode Relative Individual time pass 73 INPT J h Input J K R1MD HEAT PID ONF HYS1 3 R2MD COOL B TP ONF S...

Page 6: ...n Integral Time Derivative Time Cycle Time Manual Reset Proportional Band 2 Cycle Time 2 Manual Reset 2 Relay 3 Mode Alarm off pass 37 Case 3 INB ABO SET3 LOW 75 SET3 HI H 125 Set Point 3 Low Set Poin...

Page 7: ...is a continuous process So for more updated operating information and Support Please contact our Helpline 9081078681 9081078683 or Email at Ver 2103 service multispanindia com ALARM OPERATION R3 Alar...

Reviews: