MULTISPAN CPR 126 Manual Download Page 4

CONTROL FUNCTION

Password

Power on time

(0-99 sec)

(0-99 sec)

(0-999 sec)

(Relay fault mode)

Primary C.T ratio

Power Fault Memory

(On/Off)

(5-999 AmP)

Yes / No

Press       key for save & exit

(Initial time delay)

(Trip delay time)

Press       key

Press       key

Press       key

Press       key

Press       key

Press       key

Press       key

SET

SET

SET

SET

SET

SET

SET

SET

p a s

3 7 

P O N 

2 0 

I T D 

2 5 

T D L 

2

R F m

C T R

P F M

O N

5

Y E S

Enter password 37

Press      key 
for 5 sec

SET

Press       key

Press       key

SET

SET

Press       key

SET

Press       key

Press       key

Press       key

Press       key

SET

SET

SET

SET

a u t

r S t

r C t

    5

(Auto / Manual / ZVR)

(Reset mode)

(Recovery time)

Press       key

Press       key

Press       key

SET

SET

SET

If 

manual reset 

mode  select

(0 to 99 sec.)

If Auto/ZVR reset mode select

Under Current

Under Current - Enable   
RLY fault - OFF

Power on time = 5 sec              Initial time delay = 5 sec
Trip delay time = 5 sec 

Current

U.C Set point

OFF

TRP

Time

ON

5

10

15

20

Power
 On

ITD

TRP
Delay

OFF

R

 

 

Y

 

 

B

 

 

Reset mode = Manual

Page - 2

Asymmetry Current

Over Current

Current

SPP - Enable   

Asymmetry 
current        -    Enable

OFF

20%

Over Current - Enable   

RLY fault - Off

RLY fault     - 
Asymmetry 
percentage  -

RLY fault - OFF

Time

Single Phase Prevention

Power
 On

ITD

TRP
Delay

OFF

TRP

ON

5

10

15

20

25

Current

Power
 On

ITD

TRP
Delay

OFF
TRP

ON

5

10

15

OFF

OFF

Current

O.C Set point

Time

5

10

15

20

Power
 On

ITD

OFF
TRP

ON

OFF

R

 

 

Y

 

 

B

 

 

TRP
Delay

R

 

 

Y

 

 

B

 

 

20 % asymmetry 
current

20

R

 

 

Y

 

 

B

 

 

Time

Summary of Contents for CPR 126

Page 1: ...ery time Auto reset Secondary current AC Resolution 5 to 999 Selectable 0 5 to 5 Amp AC 0 01A 0 1A 1A Display Relay Supply voltage Dimension mm Keys Relay Type Power consumption VA RATING Rating Trip Setting Time parameter 3 digit 1line 7 seg 0 4 RED LED 1 nos 75 H x 45 W x 110 D mm SET INC DEC RST 1 C O NO C NC 3 VA 230V AC MAX 10A 230V AC 28 V DC Under current 0 00 to 100 of primary C T value Tr...

Page 2: ... clamp so the instrument fits on the DIN rail 2 Ensure proper fitting of the instrument by pulling it outwards 3 To remove the instrument raise the clamp to release it from the DIN rail 4 The equipment in its installed state must not come in close proximity to any heating source caustic vapors oil steam or other unwanted process byproducts 5 Do not connect anything to unused terminals INSTALLATION...

Page 3: ... Press key for 5 sec SET Press key for 5 sec NOTE If Auxiliary supply cut out without fault Reset Then fault will be display at next power on If Reset Mode Selected As ZVR Zero Value Reset then the Relay will be reset after Selected Reset time once the healthy condition achieved OR Zero Value reached SET To Reset fault press key O C O C A2 A3 R A1 3 4 5 A2 A3 R A1 Scroll Over current in R Phase Ov...

Page 4: ...covery time Press key Press key Press key SET SET SET If manual reset mode select 0 to 99 sec If Auto ZVR reset mode select Under Current Under Current Enable RLY fault OFF Power on time 5 sec Initial time delay 5 sec Trip delay time 5 sec Current U C Set point OFF TRP Time ON 5 10 15 20 Power On ITD TRP Delay OFF R Y B Reset mode Manual Page 2 Asymmetry Current Over Current Current SPP Enable Asy...

Reviews: