WARNING : Risk of electric shock.

Safety Precautions 

Mechanical Dimemsions & Installation

MODEL

A

96mm

96mm

92mm

92mm

3mm

52mm

56mm

B

C

D

E

F

G

DIMENSIONS

1) Prepare the panel cutout with proper dimensions as 
     show above.
2) Fit the unit into the panel with the help of clamp given.
3) The equipment in its installed state must not come in
    close proximity to any  heating source, caustic vapors, oils 
    steam, or other unwanted process by products.
4) Use the specified size of crimp terminal (M3.5 screws) to 
    wire the terminal block.Tightening the screws on the 
    terminal block using the tightening torque of the range of 
    1.2 N.m.
5) Do not connect anything to unused terminals. 
   

A

B

F

D

E

G

B

C

Read complete instructions prior to installation and 
operation of the unit. 

 Therefore, make sure to operate the instrument on a 
 correct power supply and voltage rating marked on each 
 instrument

       

Please read the "Safety Warnings" in the instruction 

       manual supplied with the instrument thoroughly and 
      completely for correct use.

 Failure to follow the safety rule can cause fire, trouble, 
 electrical shock, etc.

Warning Guidelines

To prevent the risk of electric shock power supply to the 
equipment must be kept OFF while doing the wiring 
arrangement. Do not touch the terminals while power 
is being supplied.  

To reduce electro magnetic interference, use wire with 
adequate rating & twists of the same of equal size shall 
be made with shortest connection.

Cable used for connection to power source, must have a 
cross section of 1mm orgreater. These wires should have 
insulations capacity made of at least 1.5kV.      

A better anti-noise effect can be expected by using 
standard power supply cable for the instrument.         

This equipment, being built-in-type, normally becomes a 
part of main control panel and in such case the terminals 
do not remain accessible to the end user after installation 
and internal wiring.  

Do not allow pieces of metal, wire clippings, or fine 
metallic fillings from installat-ion to enter the product or 
else it may lead to a safety hazard that may in turn 
endanger life or cause electrical shock to the operator.      

Circuit  breaker or mains switch must be installed between 
power source and supply terminal to facilitate power 
‘ON’ or ‘OFF’ function. However this mains switch or circuit 
breaker must be installed at convenient place normally 
accessible to the operator.     

Use and store the instrument within the specified ambient 
temperature & humidity ranges as mentioned in this 
manual.     

Installation Guidelines

Maintenance

The equipment should be cleaned regularly to avoid 
blockage of ventilating parts. Clean the equipment with a 
clean soft cloth. Do not use isopropyl alcohol or any other 
cleaning agent.
Fusible resistor must not be replaced by operator.        