DCA800SSK2 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #0 (09/03/09) — PAGE 29
INSPECTION/SETUP
CIRCUIT BREAKERS
To protect the generator from an overload, a 3pole, 2500
amp, main circuit breaker is provided to protect the
U,V,
and W Output Terminals
from overload. In addition, three
50 amp
load
circuit breakers have been provided to protect
the auxiliary receptacles from overload. Make sure to switch
ALL
circuit breakers to the
OFF
position prior to starting
the engine.
LUBRICATION OIL
Fill the engine crankcase with lubricating oil through the
fi ller hole, but
DO NOT
overfi ll. Make sure the generator is
level and verify that the oil level is maintained between the
two notches (Figure 26) on the dipstick. See Table 11 for
proper selection of engine oil.
Engine Oil Dipstick
Figure 26.
When checking the engine oil, be sure to check if the oil
is clean. If the oil is not clean, drain the oil by removing
the oil drain plug, and refi ll with the specifi ed amount of oil
as outlined in the
Komatsu Engine Owner’s Manual
. Oil
should be warm before draining.
Other types of motor oils may be substituted if they meet
the following requirements:
API Service Classifi cation CC/SC
API Service Classifi cation CC/SD
API Service Classifi cation CC/SE
API Service Classifi cation CC/SF
Recommended Motor Oil
Table 9.
FUEL CHECK
Refi lling the Fuel System
This generator has an internal fuel tank located inside
the trailer frame and may also be equipped with an
environmental fuel tank (Figure 27).
ALWAYS
fi ll the fuel
tanks with clean fresh
#2 diesel fuel. DO NOT
fi ll the fuel
tanks beyond their capacities.
Pay attention to the fuel tank capacity when replenishing
fuel. The fuel tank cap must be closed tightly after fi lling.
Handle fuel in a safety container. If the container does not
have a spout, use a funnel. Wipe up any spilled fuel
immediately.
Internal Fuel Tank System
Figure 27.
DANGER
Fuel spillage on a
hot
engine can cause
a
fi re
or
explosion
. If fuel spillage occurs,
wipe up the spilled fuel completely to
prevent fire hazards.
NEVER
smoke
around or near the generator.
CAUTION
ONLY properly trained personnel
who have read
and understand this section should refi ll the fuel tank
system.
Summary of Contents for WHISPERWATT DCA800SSK2
Page 21: ...DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 PAGE 21 NOTES...
Page 53: ...DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 PAGE 53 NOTES...
Page 56: ...PAGE 56 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 GENERATOR ASSY...
Page 62: ...PAGE 62 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 CONTROL BOX ASSY...
Page 66: ...PAGE 66 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 ENGINE ASSY...
Page 76: ...PAGE 76 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 WATER PUMP ASSY...
Page 86: ...PAGE 86 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 BATTERY ASSY...
Page 88: ...PAGE 88 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 MUFFLER ASSY...
Page 90: ...PAGE 90 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 FUEL TANK ASSY...
Page 92: ...PAGE 92 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 ENCLOSURE ASSY 1...
Page 96: ...PAGE 96 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 ENCLOSURE ASSY 2...
Page 100: ...PAGE 100 DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 ENCLOSURE ASSY 3...
Page 113: ...DCA800SSK2 60 HZ GENERATOR OPERATION AND PARTS MANUAL REV 0 09 03 09 PAGE 113 NOTES...