Multimetrix XA 1525 User Manual Download Page 12

English

12

Single Output Power Supplies

Functional Description

Load connection

Voltage and current

adjustment

 

Load is connected as shown above.

 

Switch the unit on.

 

Output current and voltage will be indicated by LED.

 

You should adjust the load to have the desired value.

To use the unit as a

current constant

source

 

Switch the unit on.

 

Turn the adjustments (9) and (10) clockwise to the end, and the (4)
anti-clockwise to the end.

 

Then connect your load.

 

Turn the current-adjustment (4) to get desired current.

 

The LED (2) is on and the LED (3) is off.

To use the unit as a

voltage constant

source

 

The current-adjustment (4) must be set to its maximum value.

 

Switch on power and adjust the voltage (9) and (10).

 

The LED (3) is on and the LED (2) is off.

 

To adjust the current limit : switch the unit off and short-circuit outputs
5 (+) and 7 (-).

 

Switch on again and 

turn the current-adjustment (4) to get desired 

desired limit current.

 

Switch the unit off. Enlevez le court-circuit and connect the load.

 

Switch on again.

3 digit-LCD

(resolution : 2½ digit)

To get more accurate measuring value, you should calibrate by
external circuit with precision measuring instrument.

Attention

 

This unit has excellent current-limit protection. If short-circuit 
occurs, the output current is limited.

 

As there is controlling circuit for regulating transistor’s power
loss in the circuit, when short-circuit occurs, the power loss 
on large power transistors is not very high, it can’t cause any 
damage to the unit.

 

Store the instrument in a dry, clean and ventilated place.

 

Disconnect the unit if it should remain unused for quite a long 
time.

7

6

5

Summary of Contents for XA 1525

Page 1: ...s s S S Si i in n ng g gl l le e e O O Ou u ut t tp p pu u ut t t P P Po o ow w we e er r r S S Su u up p pp p pl l li i ie e es s s N N No o ot t ti i ic c ce e e d d de e e f f fo o on n nc c ct t t...

Page 2: ...0 D finition des cat gories d installation cf CEI 664 1 CAT I Les circuits de CAT I sont des circuits prot g s par des dispositifs limitant les surtensions transitoires un faible niveau Exemple circui...

Page 3: ...ion totale de sortie de plus de 60 V cr te par rapport la terre mode commun L appareil doit tre install dans un endroit ventil Veillez ne pas obstruer les trous d a ration Symboles sur l instrument Co...

Page 4: ...ou une inondation V rification m trologique Comme tous les appareils de mesure ou d essais une v rification p riodique est n cessaire Renseignements et coordonn es sur demande T l 02 31 64 51 55 Fax...

Page 5: ...tration Organes de commande 1 Affichage digital du courant et de la tension en sortie 2 LED Indicateur de r gulation pour un courant constant CC 3 LED Indicateur de r gulation pour une tension constan...

Page 6: ...l alimentation sous tension et r gler la tension l aide des potentiom tres 9 et 10 Le voyant 3 est allum et le voyant 2 est teint Pour r gler la limitation de courant arr tez l appareil et court circ...

Page 7: ...ion 1 2 digits Courant 2 2 digits R gulation Tension 0 05 5 mV Courant 0 5 5 mA Stabilit Ondulation 1 mVrms Compatibilit lectromagn tique Immunit EN 55024 Emission EN 55022 EN 61000 3 2 EN 61000 3 3 C...

Page 8: ...DC Mains power supply Overvoltage category Supply current Consumption CAT II 110 VAC 230 VAC 10 Definition of installation categories cf IEC 664 1 publication CAT I CAT I circuits are protected by dev...

Page 9: ...to the earth common mode The instrument must be placed in a ventilated room Take care not to obstruct the ventilation holes Symbols on instrument Instructions Before opening the instrument disconnect...

Page 10: ...s or flooding Metrological verification Like all measuring or testing devices a regular check is necessary Return your instrument to your distributor for any work to be done within or outside the guar...

Page 11: ...investigation college factory electronic appliance maintenance Front panel illustration Controls 1 Output voltage and current by LED indicator 2 Constant current CC LED indicator 3 Constant voltage C...

Page 12: ...e LED 3 is on and the LED 2 is off To adjust the current limit switch the unit off and short circuit outputs 5 and 7 Switch on again and turn the current adjustment 4 to get desired desired limit curr...

Page 13: ...max Display Voltage 1 2 digits Current 2 2 digits Load regulation Voltage 0 05 5 mV Current 0 5 5 mA Stabilit Ondulation 1 mVrms EMC Immunity EN 55024 Emission EN 55022 EN 61000 3 2 EN 61000 3 3 Gene...

Reviews: