18
18
Take the product out of the packaging and place
it on a suitable surface: we suggest to use a soft
material, such as a sponge or a cloth.
Open the glass panel , rotating it as shown in
STANDING, and remove the grease filters.
BEFORE INSTALLATION , IN ORDER TO AVOID
ANY POSSIBLE DAMAGE TO THE GLASSES,
WE RECOMMEND TO REMOVE THEM BY
UNSCREWING THE EIGHT SCREWS SHOWN
IN FIG. 2. ELECTRICALLY DISCONNECT THE
LED BARS, BY USING THE SPECIFIC BIPO-
LAR ACTUATOR, AND REFIT THE GLASSES
AND THE ELECTRIC WIRING ONCE INSTAL-
LATION IS COMPLETED.
Drill the holes on the ceiling , as shown in Fig. 8,
insert the plastic plugs into the holes made, and
then fix the ceiling brackets, as shown in Fig. 4.
The brackets, which being telescopic can be adju-
sted in height , shall be secured at their minimum
extension.
Bring the hood close to the brackets previously
fixed and connect the appliance to the supply
mains.
Secure the hood to the ceiling, by using the screws
supplied, as shown in Fig. 6.
SLT970
FREE STANDING – FILTERING
VERSION INSTALLATION
SLT970
SUCKING VERSION BUILT IN
Take the product out of the packaging and place it
on a suitable surface: we suggest to use a soft ma-
terial, such as a sponge or a cloth.
Open the glass panel , rotating it as shown in Fig.
1, and remove the grease filters.
BEFORE INSTALLATION , IN ORDER TO AVOID
ANY POSSIBLE DAMAGE TO THE GLASSES,
WE RECOMMEND TO REMOVE THEM BY UN-
SCREWING THE EIGHT SCREWS SHOWN IN
FIG. 2. ELECTRICALLY DISCONNECT THE LED
BARS, BY USING THE SPECIFIC BIPOLAR AC-
TUATOR , AND REFIT THE GLASSES AND THE
ELECTRIC WIRING ONCE INSTALLATION IS
COMPLETED.
In the built-in installation, the stainless steel exter-
nal cover is not necessary (Fig. 9).
A recess shall be created , where the appliance
will be placed, which shall have a 850 mm X 470
mm rectangular opening and depth ranging from
160mm to 240 mm.
INSTALL THE HOOD ON THE CEILING, CON-
NECT THE CANAL SYSTEM FOR THE AIR
OUTLET, SET THE ELECTRICAL CONNECTION
AND THEN COMPLETE THE PLASTERBOARD
STRUCTURE.
The recess shall be provided with a socket and a
round pipe of 150mm diameter, or a similar sec-
tion, for the air outlet.
Drill the holes on the ceiling , as shown in Fig. 8, in-
sert the plastic plugs into the holes made, and then
fix the ceiling brackets as shown in Fig. 4.
The ceiling brackets are telescopic , so their height
can be adjusted at 80 mm between the ceiling and
the hood.
You can choose one of the three air out- lets shown
in Fig. 5: fit the air outlet plastic flange in the de-
sired outlet; the remaining outlets shall be closed
with the specific metal caps , as shown in fig. 5.
Bring the hood close to the brackets previously fi-
xed and then connect the appliance to the supply
mains.
Secure the hood to the ceiling, by using the screws
supplied, as shown in Fig. 6.