a. Picture Taking

1. Press the picture taking button to photograph the current image.
2. Press the right button to save the picture.
3. Press the left button to discard the picture.
Note: It is recommended to store no more than 5000 images, so as not to affect the image storage speed.

b. Temperature Unit Selection

1. Press the OK button to pop-up the main menu.
2. Press the left/right button to select the 

i

 option.

3. Press the OK button to enter the temperature submenu.
4. Press the left/right button to select °C or °F.
5. Press the back button to exit the current menu.

c. Centre Point and High/Low Temperature Tracking

To track the temperature of centre point:
1. Press the OK button to pop up the main menu.
2. Press the left/right button to select the 

 option.

3. Press the OK button to enter the submenu.
4. Press the left/right button to select the 

 option.

5. Press the OK button to confirm it.
6. Press the back button to exit the current menu.
To track high/low temperatures:
1. Press the OK button to pop up the main menu.
2. Press the left/right button to select the 

 option.

3. Press the OK button to enter the submenu.
4. Press the left/right button to select the 

 option.

5. Press the OK button to confirm it.
6. Press the back button to exit the current menu.

Summary of Contents for MP780429

Page 1: ...Page 1 V1 0 24 04 20 Newark com multicomp pro Farnell com multicomp pro Element14 com multicomp pro Thermal Imager User Manual Part Number MP780429 ...

Page 2: ...Farnell com multicomp pro Element14 com multicomp pro Table of Contents 1 Introduction 3 2 Safety Instructions 3 3 Structure 3 4 Display 4 5 Menu Introduction and Operation 4 6 USB Communication 10 7 Specifications 10 8 Maintenance 11 9 Appendix 11 ...

Page 3: ...therwise the free warranty will be voided if the product is damaged Please do not use this product in flammable explosive steamy wet or corrosive environments Please stop using the product if it is damaged or modified to avoid inaccurate test results Please use the correct emissivity value in order to obtain accurate temperature readouts To ensure the accuracy of the product please warm it up for ...

Page 4: ...ro 4 Display Display size 2 4 495mm 377mm Display resolution 320 240 pixels Item Description 1 Measured temperature 2 Thermal image display area 3 Battery level 4 Temperature option 5 Cursor option 6 Colar palette option 7 Picture playback option 8 Settings option 5 Menu Introduction and Operation ...

Page 5: ...ess the left right button to select C or F 5 Press the back button to exit the current menu c Centre Point and High Low Temperature Tracking To track the temperature of centre point 1 Press the OK button to pop up the main menu 2 Press the left right button to select the option 3 Press the OK button to enter the submenu 4 Press the left right button to select the option 5 Press the OK button to co...

Page 6: ...ter the colour palette submenu 4 Press the left right button to select the desired colour from iron red rainbow and grey 5 Press the back button to exit the current menu In addition in the image display page press the right button to switch between the current colour image and fast thermal tracking image Note The fast thermal tracking image cannot be switched to iron red rainbow or grey image by c...

Page 7: ...dialogue box asking whether to delete the picture 5 Press the left right button to select or 6 Select to delete the picture and return to the picture playback submenu 7 Select to return to the picture playback submenu 8 Press the back button to exit the current menu f Settings To enter the Settings menu 1 Press the OK button to pop up the main menu 2 Press the left right button to select the optio...

Page 8: ...ter the emissivity submenu 3 Press the OK button again 4 Press the left right button to adjust the emissivity 5 Press the OK button to save the settings 6 Press the back button to exit the current menu Note The emissivity value can be adjusted from 0 to 0 99 The default value is set to 0 95 Selecting the correct emissivity value is very important for accuracy of temperature measurement as the emis...

Page 9: ...ption left right button from settings menu 2 Press the OK button to enter the High Low Temperature Alarm submenu 3 Press the left right button to select the desired option 4 Select High Low to adjust the temperature parameter 5 Select other options to turn the alarm on or off 6 Press the back button to exit the current menu vii Device Information To view the device information 1 Select the Device ...

Page 10: ...the PC software connect the USB cable to the computer 3 Users can browse pictures and analyse data through the PC software Regarding the use of the computer software users can retrieve the Software User Manual from the Help option of the operation interface 7 Specifications Temperature Range 10 C 400 C Basic Accuracy 10 C 400 C 2 0 C or 2 of reading whichever is greater room temperature 25 C Emiss...

Page 11: ... liability for death or personal injury resulting from its negligence Multicomp Pro is the registered trademark of Premier Farnell Limited 2019 Battery 3 7V 1300mAh rechargeable lithium battery Auto power off Battery Life 3 5 hours Charging Time 2 to 2 5 hours Certification CE Storage Card 16GB Micro SD card Storage Temperature 20 C 60 C 4 F 140 F Operating Temperature 0 C 50 C 32 F 122 F Drop Tes...