3
OPERATION
Power button
•
Press and hold the power button to turn the meter on.
•
Short press the power button to turn the meter off.
•
Press and hold the power button to enable or disable auto power off function.
Unit button
•
Short press to switch between wind speed units Meters/Kilometers/Feet/KPH/MPH
•
Press and hold to switch between temperature units
o
C or
o
F.
Mode button
•
Short press to switch between max, min and average (normal) value recorded
HOLD button
•
Short press to enable or disable the data hold function.
•
Press and hold to turn on or off the LCD backlight feature.
1. Wind speed/temperature sensor
2. Measuring device
3. Flexible connection cord
4. LCD display
5. Function buttons
6. Readout device
Function
Description
Unit switch
Selectable wind speed units and temperature unit
Measurement value
Maximum/Minimum/Average value
Data hold
HOLD symbol is displayed
Overload alarm
When the wind speed exceeds 45m/s OL is displayed.
When the temperature exceeds 50
o
C OL is displayed.
When the temperature is below -10
o
C OL is displayed
Backlight
LCD Backlight on/off function
Auto power off
The meter will turn the power off if not operated for approx 5
minutes
Sampling range
Once per 0.5 second
Drop test
1m
Battery
1.5V 3 x AAA
Environment
Indoor 0
o
C~40
o
C (<90%RH)
Storage
Indoor -20
o
C~60
o
C (<75%RH)
Altitude
2000m
Pollution grade
2