3

OPERATION

Power button

• 

Press and hold the power button       to turn the meter on.

• 

Short press the power button to turn the meter off.

• 

Press and hold the power button to enable or disable auto power off function.

Unit button

• 

Short press to switch between wind speed units Meters/Kilometers/Feet/KPH/MPH

• 

Press and hold to switch between temperature units 

o

C or 

o

F.

Mode button

• 

Short press to switch between max, min and average (normal) value recorded

HOLD button

• 

Short press to enable or disable the data hold function.

• 

Press and hold to turn on or off the LCD backlight feature.

1.  Wind speed/temperature sensor
2.  Measuring device
3.  Flexible connection cord
4.  LCD display
5.  Function buttons
6.  Readout device

Function

Description

Unit switch

Selectable wind speed units and temperature unit

Measurement value

Maximum/Minimum/Average value

Data hold

HOLD symbol is displayed

Overload alarm

When the wind speed exceeds 45m/s OL is displayed.  

When the temperature exceeds 50

o

C OL is displayed.  

When the temperature is below -10

o

C OL is displayed

Backlight

LCD Backlight on/off function

Auto power off

The meter will turn the power off if not operated for approx 5 

minutes

Sampling range

Once per 0.5 second

Drop test

1m

Battery

1.5V 3 x AAA

Environment

Indoor 0

o

C~40

o

C (<90%RH)

Storage

Indoor -20

o

C~60

o

C (<75%RH)

Altitude

2000m

Pollution grade

2