multicomp pro MP760862 Manual Download Page 2

 

Features 

 3-2/3 digit (2400 count) LCD display 

 White LED backlight 

 Built-in non-contact AC voltage detector plus flashlight 

 Frequency measurement 40Hz to 1kHz 

 Autoranging with auto power off 

 0.

7” (18mm) Jaw opening 

 

Specifications

 

Display 

3-2/3    (2400  count)  Digit  LCD 
with white LED backlight 

Polarity 

 Minus sign ( - ) indicates negative 
polarity 

Current sensor 

Hall effect sensor type 

Overload indication 

“OL” displayed on the LCD 

DCA zero adjust 

One touch zero key 

Display rate 

2 readings/second, nominal 

Battery 

Two 1.5V AAA batteries 

Low Battery indication 

“BATT” displayed on the LCD 

Auto OFF                          approx. 7 minutes

 

Operating conditions 

32

º

F to 86

º

F (0

º

C to 30

º

C) 90%RH; 

86

º

F  to  104

º

F  (30

º

C  to  40

º

C) 

75%RH;  104

º

F  to  122

º

F  (40

º

C  to 

50

º

C) 45%RH 

Storage conditions 

-  14

º

F  to  140

º

F  (-30

º

C  to  60

º

C);  < 

90% Relative Humidity 

Altitude 

Operate at less than 3000 meters 

Weight 

6.2 oz. (175g) including battery 

Dimensions 

164  x  65  x  32mm    (6.5  x  2.6  x 

1.3”) (HXWXD) 

Jaw opening 

18mm    (0.7”) 

Standards 

IEC61010 Category II 600V 

Summary of Contents for MP760862

Page 1: ...200A AC DC Mini Clamp on Meter MP760862...

Page 2: ...dication OL displayed on the LCD DCA zero adjust One touch zero key Display rate 2 readings second nominal Battery Two 1 5V AAA batteries Low Battery indication BATT displayed on the LCD Auto OFF appr...

Page 3: ...Hz 1 2 5 digits Input Sensitivity 5A AC RMS min 51 510Hz 0 1Hz 0 51 1kHz 0 001kHz Non Contact AC Voltage 100VAC to 600VAC 50 60Hz Meter Description 1 Current sense jaw 2 Flashlight button 3 Rotary fun...

Page 4: ...fully followed for safe operation 1 NEVER apply voltage or current to the meter that exceeds the specified maximum 2 USE EXTREME CAUTION when working with voltages greater than 25VAC rms These voltage...

Page 5: ...y enclosing a single conductor Do not allow a gap between the two halves of the jaw Refer to the diagram at right for the correct way to enclose a single conductor 3 Read the ACA value on the LCD DC C...

Page 6: ...rub the probe tip along a length of the cord to assure placing the tip in close proximity to the live conductor NOTE The detector is designed with high sensitivity Static electricity or other sources...

Page 7: ...off Backlight display Press and hold the Hold Backlight key for more than 2 seconds to turn on the backlight This will also activate the Data Hold function To release the Data Hold function and return...

Page 8: ...e it must be treated as Waste Electrical Electronic Equipment WEEE Any WEEE marked products must not be mixed with general household waste but kept separate for the treatment recovery and recycling of...

Reviews: