Capacitance Measurement

• 

Switch the 

range selector

 to capacitance measurement 

• 

Insert the red test lead to 

VΩmA terminal

, black to COM terminal. 

• 

Connect the test probes to the capacitor being measured. 

• 

Reading is displayed.

Notes:

• 

Switch off the power supply to the circuit, and fully discharge all capacitors 

(especially for high voltage capacitors). 

• 

If the tested capacitor is shorted or its capacity is over the specified range “OL” 

symbol will be displayed on the screen. 

• 

When measuring large capacitors, it may take a few seconds to obtain steady 

readings. 

• 

When there is no input, the device displays a fixed value (intrinsic capacitance). 

• 

For small capacitance measurement, to ensure measurement accuracy, the 

measured value must be subtracted from intrinsic capacitance. Or users can 

measure small capacity capacitors with relative measurement function (REL) {the 

device will automatically subtract the intrinsic capacitance)

Battery Measurement (MP730008 only)

• 

Switch the 

range selector

 to battery measurement position.

• 

Insert the red test lead to 

VΩmA terminal

, black to COM terminal. 

• 

Connect the red test probes to + and black to - poles.

• 

The LCD displays the battery status.

Notes:

• 

Do not input over 60V DC or 30V AC.

Measuring Temperature (MP730007 only)

• 

Switch the range selector to temperature position.

• 

After “OL” is displayed insert the K-type thermocouple to the device terminals 

VΩmA and COM and and place the test probes on the object under measurement.

• 

The reading is displayed.

Notes:

• 

Only the K-type thermocouple supplied with this instrument should be used.

• 

The measured temperature should be less than 250

o

C/482

o

F.

NCV Measurement

• 

Switch the range selector to NCV position.

• 

Place the device near the object to be measured and the display shows the 

intensity of the field in a series of “-” and the buzzer sounds more rapidly as the 

field strength increases. eg:

 

“EF” : 0-50mV

 

“-”  : 50-100mV

 

“--” : 100-150mV

 

“---” :150-200mV

 

“----” : >200mV 

Auto Power Off

• 

The meter features an Auto Power Off function. It will power off automatically 

after 15 minutes inactivity and enter the sleep mode which reduces battery power 

consumption. Power on the meter again by pressing any button.

Summary of Contents for MP730007

Page 1: ...1 Model MP730007 and MP730008 Digital Multimeter ...

Page 2: ...0 seconds For current values over 5A the wait period between each measurement must be longer than 15 minutes When a measurement has been completed disconnect the testing probes from the circuit under test Replace the batteries as soon as the low battery indicator appears on the display Remove dead batteries from the meter or if it is not going to be used for a long time Never mix old and new batte...

Page 3: ...put voltage 600V AC DC the buzzer will continuously beep indicating measure range is at it s limit If the input current 10A AC DC buzzer will continuously beep indicating measure range is at it s limit Disconnect the probes from the circuit under test when changing the range If the Display shows OL it indicates the measured voltage is out of range In this case turn the range selector to a higher r...

Page 4: ...asurement When there is no input such as in open circuit condition the instrument will display OL When making an in circuit measurement disconnect all power supplies and discharge all the capacitors When measuring low resistance the test leads will produce 0 1Ω 0 2Ω measurement error To obtain accurate measurement short the test leads and use REL function If the resistance when shorted is more tha...

Page 5: ...nge selector to battery measurement position Insert the red test lead to VΩmA terminal black to COM terminal Connect the red test probes to and black to poles The LCD displays the battery status Notes Do not input over 60V DC or 30V AC Measuring Temperature MP730007 only Switch the range selector to temperature position After OL is displayed insert the K type thermocouple to the device terminals V...

Page 6: ... 0 2 6 000kΩ 6000Ω 0 1kΩ 1Ω 0 8 2 60 00kΩ 0 01kΩ 0 8 2 600 0kΩ 0 1kΩ 0 8 2 60 00MΩ 0 01MΩ 2 0 5 DIODE TEST Range Resolution Remarks 0 001V MP730007 Open circuit voltage 4V test current about 1 5mA MP730008 Open circuit voltage 2 1V test current about 1mA Silicon PN junction voltage 0 5 0 8V OPERATING PARAMETERS Ambient temperature 23º 5º Relative Humidity 75 DC VOLTAGE Range Resolution Accuracy 60...

Page 7: ... is only applicable for temperature less than 250ºC 482ºF CAPACITANCE Range Resolution Accuracy 9 999nF 0 001nF REL mode 4 10 99 99nF 0 01nF 4 5 999 9nF 0 1nF 4 5 9 999µF 0 001µF 4 5 99 99µF 0 01µF 4 5 999 9µF 0 1µF 4 5 9 999mF 0 001mF 10 DC CURRENT Range Model Resolution Accuracy 600 0µA MP730007 MP730008 0 1µA 1 0 3 6000µA MP730007 1µA 1 0 3 60 00mA MP730007 MP730008 0 01mA 1 0 3 600 0mA MP73000...

Page 8: ... ELECTRICAL ELECTRONIC EQUIPMENT These symbols indicate that separate collection of Waste Electrical and Electronic Equipment WEEE or waste batteries is required Do not dispose of these items with general household waste Separate for the treatment recovery and recycling of the materials used Waste batteries can be returned to any waste battery recycling point which are provided by most battery ret...

Reviews: