FUNCTIONS
Tracing Cables
•
On the Tone Generator set the function switch to TONE position.
•
The TONE and POWER LEDs will illuminate.
•
Connect the red test lead to the wire in the cable you wish to trace and connect
the black lead to ground.
•
If the cable is shielded connect the black lead to the shield.
•
Point the probe tip to the cable and
press the TEST button.
•
The POWER LED on the probe will
illuminate.
•
Adjust the volume/sensitivity slider
so the output is easily audible.
•
The volume will be loudest when
the probe tip is close to the wire
connected to the tone generator.
Tracing Pairs
•
On the Tone Generator set the function switch to TONE position.
•
The TONE and POWER LEDs will illuminate.
•
Connect the red test lead to one wire of the cable and connect the black lead to
the other wire of the pair being
traced within the cable.
•
Point the probe tip to the cable
and press the TEST button.
•
The POWER LED on the probe
will illuminate.
•
Adjust the volume/sensitivity slider
so the output is easily audible.
•
The volume will be loudest when
the probe tip is close to the wires
connected to the tone generator.
Indicating Line Conditions (Checking Polarity)
•
On the Tone Generator set the function switch to POWER position.
•
Connect the red test lead to one wire and the black lead to the other wire of the
telephone line being tested.
•
If the CONTINUITY LED turns green
a normal working line with correct
polarity is indicated.
•
If the TONE LED turns red, incorrect
polarity is indicated.
•
If the CONTINUITY LED turns dark
green, a faulty or off-hook line with
correct polarity is indicated.
•
If the TONE LED turns dark red, a
faulty or off-hook line with incorrect
polarity is indicated.