multicomp pro MP700006 Manual Download Page 3

3

FUNCTIONS

Tracing Cables

• 

On the Tone Generator set the function switch to TONE position.

• 

The TONE and POWER LEDs will illuminate.

• 

Connect the red test lead to the wire in the cable you wish to trace and connect 

the black lead to ground. 

• 

If the cable is shielded connect the black lead to the shield.

• 

Point the probe tip to the cable and 

press the TEST button.

• 

The POWER LED on the probe will 

illuminate. 

• 

Adjust the volume/sensitivity slider 

so the output is easily audible.

• 

The volume will be loudest when 

the probe tip is close to the wire 

connected to the tone generator.

Tracing Pairs

• 

On the Tone Generator set the function switch to TONE position.

• 

The TONE and POWER LEDs will illuminate.

• 

Connect the red test lead to one wire of the cable and connect the black lead to 

the other wire of the pair being 

traced within the cable. 

• 

Point the probe tip to the cable 

and press the TEST button.

• 

The POWER LED on the probe 

will illuminate. 

• 

Adjust the volume/sensitivity slider 

so the output is easily audible.

• 

The volume will be loudest when 

the probe tip is close to the wires 

connected to the tone generator.

Indicating Line Conditions (Checking Polarity)

• 

On the Tone Generator set the function switch to POWER position.

• 

Connect the red test lead to one wire and the black lead to the other wire of the 

telephone line being tested. 

• 

If the CONTINUITY LED turns green 

a normal working line with correct 

polarity is indicated.

• 

If the TONE LED turns red, incorrect 

polarity is indicated.

• 

If the CONTINUITY LED turns dark 

green, a faulty or off-hook line with 

correct polarity is indicated.

• 

If the TONE LED turns dark red, a 

faulty or off-hook line with incorrect 

polarity is indicated.