IN
4
Innovation. Quality. Performance. Best in Industry. Worldwide.
Power Lockout Instructions
MultiCam
machines are equipped with a built-in main power lockout device. If any kind of repair work or
maintenance is being performed to the machine or control cabinet, the operator should
disconnect power
from
the machine
before starting work
.
1. Turn the main disconnect switch to the OFF position.
2. Flip out the plastic lockout latch.
3. Insert any padlock into one of the holes of the lockout latch. With the plastic lockout latch in this position,
the switch cannot be moved to the ON position.
1 2 3
4. Throw the bulkhead switch to the OFF position.
5. Open the control cabinet.
6. Make sure the LEDs on the drives and inverters are not lit. It may take a few minutes for the light from the
LEDs to fade away.
7. Make sure the incoming voltage for L1, L2, and L3 is 0v.
8. Follow the operator’s standard Tag Out procedure in tagging the disconnect switch.
Routers * Lasers * Plasma * Water Jets * Knife Cutters
www.MultiCam.com v. 03 13