MULTI MEASURING INSTRUMENTS MCL-800IR Instruction Manual Download Page 1

 

 

 

Io/Ior CLAMP LEAKER 

 

MCL-800IR 

 

 

INSTRUCTION MANUAL 

 

 

              Thank you very much for selecting our Io/Ior clamp leaker 

model MCL-800IR.   
 

              This model is complex instrument and employ a very reliable 
              mechanical/electronic design. 
                

  Before you use your new instrument, read this instruction 

              manual completely and familiarize yourself thoroughly with   
              all functions and keep this instruction manual carefully to   

take out whenever you need. 

    
 
 
 
 
 
                  MULTI MEASURING INSTRUMENTS CO.,LTD. 
                  Akihabara Murai Bldg., 7F, 1-26 Kanda Sakuma-cho, 
                  Chiyoda-ku, Tokyo, 101-0025 Japan 
                  TEL : 81-3-3251-7013    FAX : 81-3-3253-4278 
                  Home Page : 

http://www.multimic.com/

 

                  E-mail : 

[email protected]

 

Summary of Contents for MCL-800IR

Page 1: ...Before you use your new instrument read this instruction manual completely and familiarize yourself thoroughly with all functions and keep this instruction manual carefully to take out whenever you ne...

Page 2: ...al damage can be supposed caused from mis operations A E A WARNING 2BPOSSIBLE ELECTRICAL SHOCK This instrument is for the use of low voltage circuit Do not make measurements of power lines carrying mo...

Page 3: ...min resolution 0 001mA Ior 0 10A 4 range auto min resolution 0 01mA V 0 500V 1 range min resolution 0 1V M Calculated by voltage and current 0 10M min resolution 0 001M Input frequency range 50Hz 60Hz...

Page 4: ...0A 0 001A 1 000 9 999A Ior 10mA 0 001mA 0 9 999mA 1 5 rdg 20dgt 100mA 0 01mA 10 00 99 99mA 1 5 rdg 15dgt 1000mA 0 1mA 100 0 999 9mA 10A 0 001A 1 000 9 999A V 500V 0 1V 0 499 9V 1 0 rdg 10dgt The condu...

Page 5: ...current and clamp method Open Close Lever CT will open by pushing this lever to inside Power Switch POWER By pressing this switch the power becomes on and pressing once again power off Voltage Displa...

Page 6: ...correctly By pressing once the circuit setting is 1 and twice is and three times is Y Frequency Switch Select 50Hz or 60Hz according to the circuit to be measured Data Hold D HOLD By pressing one tim...

Page 7: ...ument B sign will appear on the display when batteries are exhausted and get less than operation voltage Replace to new batteries immediately Do not use the batteries mixed new one and once used and o...

Page 8: ...ot use the instrument leaving the battery cover off If excessive current is applied to the CT the instrument will be heated and damaged Do not apply more than 50Arms to the CT part Do not apply more t...

Page 9: ...case of 3 phase 3 Voltage Measurement 500V Range 1 Press POWER switch once All display lightens and the range becomes Io current measurement 2 Press Voltage display switch once and the display changes...

Page 10: ...the instrument is looking for phase angle of current and voltage Take care for wiring sufficiently Also if frequency setting is not correct the phase angle is changed and the correct measurement canno...

Page 11: ...switch once Check if the input voltage is correct Press current range switch and select Ior circuit mode to be measured Current range switch will be changed as under by pressing one time 5 To measure...

Page 12: ...b In case of Single Phase Three Wires Measuring Mode 1 Ior c In case of Three Phase Three Wires Measuring Mode Ior White Red White Red LOAD LOAD Red Red White White Black Black LOAD...

Page 13: ...large current fluctuation to be measured however the measurement cannot be done In this case fix the current range by manual mode and make measurement Operation of Manual Range 1 Press Power Switch on...

Page 14: ...ng your name address phone number and defect point WARRANTY This instrument is sent out from our factory after the sufficient internal inspections but if you find any defect due to the fault in our wo...