S3. SPECIFICATIONS 

 

Safety standard : Meets the requirements for double insulation to IEC61010-2-032, 

IEC61010-1, installation Category

600V phase to earth. 

E.M.C. standard : The instrument meets EN61326 and EN61000. 
Withstanding voltage : AC 5500V, 1 minute (between outer case and core of CT)     
Jaw opening capability : 40mm

φ

 

Current : AC 10mA/50mA/500mA/1A/5A/50A/500A 
                  Accuracy :

±

3% of F.S.(50/60Hz) 

Voltage : AC 0~500V   
                  Accuracy :

±

3% of F.S.(50/60Hz) 

Resistance : 0~1K

Ω

(50

Ω

  center) 

                        Accuracy :

±

3% of scale length 

Analog data output for recorder: DC 100mV for full scale 
Operating temperature : 0

  to 40

80%RH (non-condensing) 

Strange temperature :

10

  to 60

70%RH (non-condensing) 

Power supply : 1.5V (“ AAA” size, R03) x2 
Size : 69(W)x210.5(H)x34(D)mm 
Weight : Approx. 403g   
Accessories : Carrying case…………..1 

Instruction manual……1 
Batteries…………………2 
Test lead…………………1set 

 
 
 
 

4. DIMENSIONS AND PANEL FUNCTION       
                               

 

Current transducer (Jaw) 

 

Jaw opening lever 

 

Range selector switch 

 

Meter lock knob 

 

Zero 

Ω

  adjustment knob 

 

Pointer                                                                                             

 

 

Pointer zero adjustment screw

                       

⑭                                                                                                                                                             

 

 

Input terminal (V) (

Ω

)

                                           

 

⑨ 

COM terminal

 

⑩ 

Terminal for recorder (REC) 

⑪ 

Battery cover 

⑫ 

Wrist strap

                                           

 

⑬ 

Filter Switch 

⑭ 

Power/battery check switch 

                                           

 

 
 
 
 
 
 
 

Summary of Contents for MCL-350

Page 1: ...Before you use your new instrument read this Instruction Manual completely and familiarize yourself thoroughly with all functions With proper use and care your tester will give you years of satisfact...

Page 2: ...o factories buildings etc Before operating this instrument familiarize yourself with all instructions outlined in this manual Always check to make sure that the function switch is set to the proper po...

Page 3: ...enter Accuracy 3 of scale length Analog data output for recorder DC 100mV for full scale Operating temperature 0 to 40 80 RH non condensing Strange temperature 10 to 60 70 RH non condensing Power supp...

Page 4: ...within the BATT mark the batteries are usable If the pointer indicates outside the mark the batteries are exhausted In this case replace the batteries with new ones Set the Zero 0 position of the poi...

Page 5: ...e to the current to be measured Clamp the conductor of the circuit at the center of CT Read the current value of the current scale If you make measurements in a dark place or in a place where it is di...

Page 6: ...TIMES OF THE NORMAL SUPPLY VOLTAGE THIS INSTRUMENT SHOULD NOT BE USED TO MEASURE POWER LINES The term of Power Line mean the electrical circuit providing the power to factories buildings and etc WARN...

Page 7: ...tment knob Contact the tips of the test leads to the circuit under test Read the resistance on the scale Fig 3 CAUTION Be sure all voltage is turned OFF in the circuit before making resistance measure...

Page 8: ...tteries or fuse remove all electrical inputs Do not replace the batteries under the conditions of clamping CT to the conductor and or inputting voltage to the terminals Do not use the mixed batteries...

Reviews: