3. CARRY AND STORAGE 

 

* Take care not to drop down the instrument and or not to load heavy weight and 
    or strong shock to the instrument.   
* Do not apply chemicals to this instrument. 
* Do not leave this instrument on the road and or the place under the direct sunshine 
    during summer and also do not leave it in the high temperature place, such as 
    inside of the car, etc. 
* Keep the instrument clean and chose the storage place where is dry and not getting           
    direct sunshine

   
4. SPECIFICATION 

  Measuring method                                  Dual integration mode 
  Measuring function                                AC line current 
  Display                                                      3.5 digit LCD, max, reading of 1999 with   
                                                                        annunciators 
  Range                                                        0

20A/600A(50/60Hz) 

  Ranging                                                    2 manual ranging 
  Accuracy                                                    23

℃±

5

, 80RH or less 

 
 

Range 

Resolution 

Accuracy 

20A 

                0.01A 

±

2.0% rdg 

±

8 dgt 

600A 

                    1A 

0

400A

±

2.0% rdg 

±

8 dgt 

400

600A

±

3.0% rdg 

±

8 dgt 

 

 
Jaw opening capability                        35mm

φ

 

Low battery indication                        Display "B" mark on LCD readout 
Over range indication                          Blanking of all digits except MSD1 
                                                                    (Except 600A range) 
Sampling                                                2 times/sec 
Peak hold indication                            "PEAK" LED lamp indication 
Insulation resistance                          100M

Ω

  or more by DC 1000V insulation tester 

                                                                    (Between operation handle and core of CT) 
Withstanding voltage                          AC 15KV, 1 minute (Between handle and core 
                                                                      of CT) 
                                                                  AC 100KV, 5 minute (Between rod of hot stick 
                                                                      and core of CT). 
Limitation of circuit voltage              AC 80V to 46KV with hot stick 
Power supply                                        1.5V("AAA" size) x2 
Structure                                                Water resistance rank

(Japanese standard) 

Size                                                          70(W) x 356(H) x 32(D)mm 
Weight                                                    Approx. 370g 
Accessories                                            Carrying case…………..1 
                                                                  Instruction manual….…1 
                                                                  Batteries…………………2 
Option                                                      Hot stick (2m, 5m, 10m, 12m) 