The Line Hunter is a rack mounted panel that is designed
to be screwed to a standard (EIA) 19.00" or 23.00"
equipment rack cabinet or wall bracket using
four 5/8" x 12-24 screws (supplied).
1 . Slide Line Hunter into equipment rack and secure with 4 screws.
2. Plug the AC power cord into AC receptacle.
3. Program Dip Switch (if factory default settings are not suitable for application).
4. Insert device patch cords in appropriate port on Line Hunter panel. Use standard 6 or 8 position modular
plugs.
7 TECHNICAL SPECIFICATIONS
I nput Power Requirements
Voltage: 110-125 Volts AC only, 50-60 Hz
Current: less than 1 OOmA
CO Interface:
REN: (to be determined)
I nput Ring Detection: 40-150 Volts AC, 15-68 Hz.
Device Interface:
Battery: -48 Volt DC to all 12 device ports
Off-Hook detection: 6-150 mA
Power Consumption: 12 Watts
Connectors:
CO Interface: 11 0-type-4-pair punch-down
Device Interface: 8-position modular, compatible with both standard 6-position RJ-1 1 and 8-position
modular plugs.
Trunking: 12 device ports/ 4 CO line ports
225 Industry Parkway - Nicholasville, KY 40356 - Ph. 800-535-4651
or
1 2