background image

600 Cardigan Road

Shoreview, Minnesota 55126

Phone 651-481-1900

www.multi-clean.com

Changing and cleaning nozzle

Remove battery from unit. 

Insert nozzle wrench into nozzle cavity. Rotate wrench to engage the 

tabs on nozzle. Rotate counter clockwise, about 90 degrees, until the 

nozzle becomes loose. Remove nozzle and clean with warm water.

To re-install nozzle, insert nozzle into wrench lining up nozzle tabs 

with slots in wrench, insert nozzle and wrench into front opening of 

unit. Push in and rotate wrench clock wise approximately 90 degrees. 

Remove wrench, re-install battery.

To change to a different size spray, rotate nozzle face clockwise until 

the desired nozzle orifice lines up opposite of arrow or you hear a click 

sound indicating the tip is aligned correctly. The 80 micron (Green 

tip) is best suited for most products and will give you approximately 

8 minutes per 33 ounces of product.

Page 2   004509-01072020

Nozzle

Size

40 red

80 green

110 white

Minutes 

per Tank

11

8
3

Square Feet

per Tank

3300
2400

900

Tanks 

per Charge

18
24
80

Ounces 

per Minute

3
4

11

Certified Products for Use in 

the E-Spray System

17 Odor-Rite Tropical Deodorizer
64 Millennium Q Disinfectant
128 E-Fecticide Disinfectant
256 Century Q Disinfectant
Chlorinated Tablets Disinfectant
Microcide TB disinfectant

PPE recommendation

• Latex gloves

• Wrap around eye protection

• N95 rated dust mask