600 Cardigan Road
Shoreview, Minnesota 55126
Phone 651-481-1900
www.multi-clean.com
Changing and cleaning nozzle
Remove battery from unit.
Insert nozzle wrench into nozzle cavity. Rotate wrench to engage the
tabs on nozzle. Rotate counter clockwise, about 90 degrees, until the
nozzle becomes loose. Remove nozzle and clean with warm water.
To re-install nozzle, insert nozzle into wrench lining up nozzle tabs
with slots in wrench, insert nozzle and wrench into front opening of
unit. Push in and rotate wrench clock wise approximately 90 degrees.
Remove wrench, re-install battery.
To change to a different size spray, rotate nozzle face clockwise until
the desired nozzle orifice lines up opposite of arrow or you hear a click
sound indicating the tip is aligned correctly. The 80 micron (Green
tip) is best suited for most products and will give you approximately
8 minutes per 33 ounces of product.
Page 2 004509-01072020
Nozzle
Size
40 red
80 green
110 white
Minutes
per Tank
11
8
3
Square Feet
per Tank
3300
2400
900
Tanks
per Charge
18
24
80
Ounces
per Minute
3
4
11
Certified Products for Use in
the E-Spray System
17 Odor-Rite Tropical Deodorizer
64 Millennium Q Disinfectant
128 E-Fecticide Disinfectant
256 Century Q Disinfectant
Chlorinated Tablets Disinfectant
Microcide TB disinfectant
PPE recommendation
• Latex gloves
• Wrap around eye protection
• N95 rated dust mask
E-Spray Hand Held
Electrostatic Sprayer
110
80
40