2    Important Information and Instructions 

2.1   Operator's Obligations  

The operator is obliged to allow only persons to work on the device, who    

 

are familiar with the safety at work and accident prevention regulations and have been instructed  
how to use the device;    

 

are professionally qualified or have specialist knowledge and training and have received instruction  
in the use of the device;    

 

have read and understood the chapter on safety and the warning instructions in this manual and 
confirmed this with their signature.  

  

It must be monitored at regular intervals that the operating personnel are working safely.  

Personnel still undergoing training may only work on the device under the supervision of an experienced 
person.  

  

  

2.2   Guarantee and Liability  

The general conditions of sale and delivery of Multi Channel Systems MCS GmbH always apply. The operator 
will receive these no later than on conclusion of the contract.  

Multi Channel Systems MCS GmbH makes no Guarantee as to the accuracy of any and all tests and data 
generated by the use of the device or the software. It is up to the user to use good laboratory practice to 
establish the validity of his findings.  

  

Guarantee and liability claims in the event of injury or material damage are excluded when they are the result 
of one of the following: 

 

Improper use of the device.   

 

 Improper installation, commissioning, operation or maintenance of the device.   

 

Operating the device when the safety and protective devices are defective and/or inoperable.   

 

Non-observance of the instructions in the manual with regard to transport, storage, installation, 
commissioning, operation or maintenance of the device.  

 

Unauthorized structural alterations to the device.   

 

Unauthorized modifications to the system settings.   

 

Inadequate monitoring of device components subject to wear.   

 

Improperly executed and unauthorized repairs.   

 

Unauthorized opening of the device or its components.   

 

Catastrophic events due to the effect of foreign bodies or acts of God. 

   

Summary of Contents for PGA16

Page 1: ...1 Programmable Gain Amplifier PGA Manual...

Page 2: ...the publisher and the author be liable for any loss of profit or any other commercial damage caused or alleged to have been caused directly or indirectly by this document 2018 Multi Channel Systems M...

Page 3: ...e of the PGA 8 3 1 Welcome to the Programmable Gain Amplifier 8 3 2 Installing the Software 9 3 3 Setting Up and Connecting the PGA 9 4 Operating the PGA 11 4 1 Adjusting the Gain Settings 11 4 2 Sign...

Page 4: ...n about the installation and first steps The printed manual and help are basically the same so it is up to you which one you will use The help offers you the advantage of scrolling through the text in...

Page 5: ...an on conclusion of the contract Multi Channel Systems MCS GmbH makes no Guarantee as to the accuracy of any and all tests and data generated by the use of the device or the software It is up to the u...

Page 6: ...sed on humans High Voltage Electrical cords must be properly laid and installed The length and quality of the cords must be in accordance with local provisions Only qualified technicians may work on t...

Page 7: ...ractice to establish the validity of his findings To the maximum extent permitted by applicable law in no event shall Multi Channel Systems MCS GmbH or its suppliers be liable for any special incident...

Page 8: ...el from the drop down list and download the settings onto the amplifier via the USB port You can print a report sheet and save the gain configuration for later use Standard versions of the PGA are ava...

Page 9: ...can use an USB hub for connecting the PGA to the computer for example if you have no free USB port or if you need to extend the USB cable Please note that other devices that are connected to the same...

Page 10: ...collector connected to miniature preamplifiers to the 68 pin MCS standard input connector of the PGA 3 Connect the 68 pin MCS standard output connector to the MC_Card input of the data acquisition co...

Page 11: ...Download button to apply the settings to the PGA 5 It is recommended to print out the gain settings for later reference by clicking the Print button 6 If you want to keep the pattern for future use sa...

Page 12: ...ifier to check the bandwidth of the amplifier version that you have in use If you have a complete ME System with MC_Card you can use the digital filter of the MC_Rack program to change the pass band a...

Page 13: ...tissue This way background or noise signals that are picked up by both the reference electrode and the recording electrodes are removed from the recording signal already in the miniature preamplifier...

Page 14: ...anual or help first Most problems are caused by minor handling errors Contact your local retailer immediately if the cause of trouble remains unclear Please understand that information on your hardwar...

Page 15: ...r operating the PGA Possible causes Loose cable or bad contact The power distribution from the IPS10W in the connected computer is obstructed Unplug and reconnect the 68 pin MCS standard cable connect...

Page 16: ...51 66 Channel 49 64 only used in PGA64 PGA3264 Pin 67 Positive supply voltage Pin 68 Negative supply voltage PGA Output 68 Pin MCS Standard Connector Pin 1 GNDP Power Ground Pin 2 GNDI connected to G...

Page 17: ...ides the opportunity for you to exchange your experience or thoughts with other users worldwide Mailing list If you have subscribed to the Mailing List you will be automatically informed about new sof...

Page 18: ...NX NN is the total number of channels X is the input type S or I with custom gain and bandwidth Amplifier with programmable gain 16 channels PGA16 Gain programmable from 10 to 5000 Amplifier with prog...

Page 19: ...rding system with 64 analog channels and filter amplifier with fixed gain ME64 FA System Complete with 2 x MPA32I SC2x32 FA64I data acquisition computer with MC_Card and IPS10W and software package ME...

Page 20: ...f 54 Electrode acute probes from NeuroNexus Technologies to two 32 channel miniature preamplifiers MPA32I Signal collector for 8 x MPA8I SC8x8 Collects the 8 channels from each of the up to 8 miniatur...

Page 21: ...ode array FlexMEA72 With 72 electrodes in total 72 electrodes arranged in an 8 x 9 grid 4 reference electrodes 4 ground electrodes 100 m electrode diameter 625 to 750 m interelectrode distance TiN ele...

Page 22: ...22...

Reviews: