background image

Instruction Manual - 
Time switch                                                                      

                                                                                                        

   

en

Connection diagram

11 12

7

8

9

1

2

3

A

B

C

17 18

D

14 15

10

16

6

13

Ext1

4
L
~

+

5
N
~

-

DCF

GPS

*

*

*

OUTPUT
 12V DC
  80 mA

The installation and assembly of electrical 
equipment must be only carried out only by a skilled 
Person! Otherwise fire danger or danger of an 
electric shock exists!
Connect the supply voltage/frequency as stated on 
the product label! 

Warranty void if housing opened by unauthorised 
person!

The electronic circuit is protected against a wide 
range of external influences. Incorrect operating 
may occur if external influences exceed certain limits! 

1. Safety instructions

The device can be used in following applications: Illumination of private and 
industrial areas, street and shop-window lightening, regulation of air 
conditioning, flushing, motors, pumps, plants and machinery as well as to 
simulate presence etc. 
Operate the device in a dry room only.
The device is not qualified for security relevant tasks such as emergency 
doors, fire protection equipment

2. Intended use

See device
AgSnO
AgNi
IP 20 nach DIN EN 60529
-30° ... +55°
1 BSTU
2
4 kV
DIN EN 60730-1/DIN EN 60730-2-7
Ideal for modern lamps

2

Supply voltage
Contact material (110-230V AC) 
Contact material (12-24V AC/DC)
Type of protection
Permitted ambient temperature
Mode of operation
Degree of contamination
Rated surge voltage
Standard
CFL, LED

3. Technical data

DIN-rail mounting product:

4. Battery

c

Defective wire between antenna and time switch (No antenna symbol 
visible / The oscillating crystal is used as time base)

c

Reception is not possible if severe interference is present (Permanent 
flashing of the symbol / The oscillating crystal is used as time base)

Antenna symbol (LCD) flashes for approx. 3 minutes 

Connect supply voltage 

Connect the antenna as indicated by the connection diagram 

Disconnect power supply voltage 

The time switch is prepared for use with a radio receiver 
(DCF/GPS) prepared.
The radio receiver is not included.

5. Installation of the radio receiver

If required, date, time and daylight savings time mode can be adjusted 
also by pressing 

r

 

q

 -buttons and a subsequent confirmation with 

s

The current date and time is already programmed and European 
daylight savings time is activated.

Select the desired language by pressing

 

r q

-buttons and confirm it by 

pressing 

s

 

. (Remark: By pressing

 

t

 you move one step backwards 

rom the current position).

Press

 

s

 

t

 

 button to wake it up.  

The time switch is delivered in sleep-mode, the display is switched off.

6. Initial operation

 

f  

OK

 

f  

0

12

24

18.06.2020

9:28

00

 

f  

OK

 

f  

0

12

24

 

f  

OK

 

f  

0

12

24

 

f  

OK

 

f  

0

12

24

 

f  

OK

 

f  

0

12

24

MONday

PROGRAM

ADJUSTMEN

TS

OPTIONs

END

PROGRAM

New

PROGRAM

query

PROGRAM

edit

PROGRAM

delete

LN

PROGRAM

Simulation

PROGRAM

END

Date-Time

Summertim

me

Astro

DatA

LANGUAGE

N

FACTORY
DEFAULTS

END

COUNTER

pin-code

EXTRA

sWITCHING

CyCLE

RANDOM

inPUT

END

7. Menu overview

Current state is based on a switching time with cycle function.

L

Element within sub-menu “program delete”.

Z

Current state is based on a switching time with pulse function.

I

Current state is based on a manual over-ride. The state is permanent until terminated manually. 

P    

Current state is based on a manual over-ride. The state will be cancelled with the next programming step.   

H

Standard programming step    

U.    

Days of the week Monday, Tuesday, ... Sunday; The underscores indicate if the program is active for the days above. 

1234567

Channel is switched OFF    

y

   

Channel is switched ON     

x

   

8. Symbol legend

2. To confirm the selection or the entered data. 

1. To activate the time switch when operated without power supply. 

f.

2. Automatic-mode: A push longer than 3 sec. = Permanent switching status.

1. Automatic-mode: To switch the channel ON or OFF until the next programming step occurs.

D

C

B

A

2. To scroll through a choice.

1. To adjust the flashing digit.

2. To revert to the beginning of the current (sub-) menu. 

f.

1. To access the Enter-mode (program, adjustments, options) from the automatic-mode. 

9. Key function

With 

r

 

q

  the choice changes from

 END

 

to

 

ConTinue.

  By confirming 

ConTinue

 

mit 

 

s

 the time switch returns s to the beginning of the current 

(sub-) menu. 

 

After completion of a (sub-) menu confirming  

END

 with 

s

 will return the device 

into the automatic-mode.

To revert one step or one level back while in the Enter-Mode press

 

t

.

The time switch is programmable without external power supply after pressing 
the

 

s

-button. 

10. Handling advice

By pushing         -buttons a manual switch of the 
channels take place. The resulting switching status is 
marked with the hand-symbol and remains until the 
next programming step occurs (temporary over-ride). 

H

11. Channel ON / OFF 

12. Permanent  

P

By pressing the corresponding channel button for 
more than 3 sec. the channel is permanently switched 
ON or OFF. The status remains until the next manual 
switching occurs (> 3 sec.) (permanent over-ride). 

 

f  

OK

 

f  

0

12

24

18.06.2020

9:28

00

 

f  

OK

 

f  

0

12

24

 

f  

OK

 

f  

0

12

24

 

f  

OK

 

f  

0

12

24

 

f  

OK

 

f  

0

12

24

MONday

PROGRAM

PROGRAM 
NEw

Channel A

Standard

OK

M

 

f  

OK

 

f  

0

12

24

PROGRAM

13. b) Standard weekly program   

Standard

 

f  

OK

 

f  

0

12

24

Program
new

 

f  

OK

 

f  

0

12

24

channel ...

OK

M

Special
Program

Permanent

ENDE

ON

CYCLE

OFF

PULSE

END

Monday
JA

Tuesday
JA

Wednesday
Ja

Thursday
JA

Friday
JA

Saturday 
NEIN

Sunday 
NEIN

1 2 3 4 5 6 7

time
hour

0

 

00

:

1 2 3 4 5 6 7

time
Minute

0

 

00

:

1 2 3 4 5 6 7

Next
Switching

END

OK

OK

OK

M

If you want to proceed with programming, confirm

 

Next Switching

 with 

s

.

To leave the programming menu change with 

r q

 to 

End

 

and confirm with 

s

.

Adjustment of the time: Hours 

r q

 and 

s

, Minutes 

r q

 and 

s

Within this level you activate the days of the week (1…7) on which the switching time should happen. With 

r q

 -buttons you

activate 

yes

 or deactivate 

No

 the corresponding date. Confirm each date with 

s

.

For regular switching times choose 

ON

 or 

OFF

 with 

r q

 -buttons and confirm with 

s

.  

If you want to program a standard weekly switching time (

ON

 / 

OFF

) confirm 

Standard

 

with 

s

13. c) Example for the programming of STANDARD switching times (

ON 

and

 OFF

)

 

f  

OK

 

f  

0

12

24

PROGRAM

14. Special program Entry (within yearly time switches)  

Standard

 

f  

OK

 

f  

0

12

24

Program
new

 

f  

OK

 

f  

0

12

24

Channel ...

OK

M

Special
Program

Permanent

END

SP 
01

END

OK

M

SP
10 

SP 
Entry

END

SP 
activation

SP 
on

SP 
cYcLe

SP 
off

END

SP
pulse

OK

MONday
yes

time
hour

0

 

00

:

time
Minute

0

 

00

:

pulse
Minute

0

 

00

:

pulse
Second

0

 

00

:

Next
Switching

END

The yearly function of the switch is realised by special (weekly) programs which can be called up by date. Up to 
10 special (weekly) programs can be entered  (

sP

 

01

      

 SP10

). 

Execution of the Special program only after activation by date (SP activation see point 15).

c

Some rules for the programming of Special programs 

Define the program number in which the new step will be an element before a new switching step is entered.  
(SP 01 – SP 10

)  

The number of switching times which can be programmed in each special program is only limited by the total 
number of free memory locations: (SP on, SP off, SP cycle, SP pulse) 
The dates/times of the year during which the special program should be applied can be entered within the 
activation menu (point 15

).  

Each special program can be activated as often as there are memory locations are available (point 15).  
During the activation dates of special programs only switching steps of the special program with highest priority 
will be executed. Remaining special and standard programs are disabled.

    

Please note the priorities of the different switching programs (point 23).        

 

f  

OK

 

f  

0

12

24

PROGRAM

15. Special program activation by date (within yearly time switches)

Standard

 

f  

OK

 

f  

0

12

24

Program
new

 

f  

OK

 

f  

0

12

24

Channel ...

OK

M

Special
Program

Permanent

ENDE

SP 
01

END

OK

M

SP
10 

SP 
Entry

END

SP 
activation

START SP
Month

START SP 
day

START SP
hour

START SP
Minute

Next 
switching

END

A special program will only be executed if it is activated. You can choose the special program  
(SP 01 – SP 10), the start/end time (date and time) for activation and additionally following options: 

FUNcTION STANDARD

: Special program will be applied each year fixed to the entered dates and times

Function easter

 The time switch takes into account the yearly shift of the Easter holiday for 

following years and corrects the activation dates. (For programs relative to Easter, Pentecost Carnival, 
Ascension,...)

Function with year

: Special program is executed once by date with year and time (“century function“ 

- requires 2 memory locations)         

END SP
Month

End SP 
day

End´ SP
hour

End SP
Minute

Function
Standard

Function
easter

Function
with year

END

23

 

59

:

N    

Y

   

A

D

DCF / GPS: The time switch receives the time signal from the time signal antenna.

c
c

Additionaly at yearly time switches

F

Switching function / switching time with Easter function: The switching function takes into account the yearly shift of Easter holiday 
for future years and changes the date of the switching program accordingly.

e

Is displayed if the corresponding channel is activated by the external input.

Current state is based on a switching time with astro function.

S

The time switch is locked; to unlock the device the PIN has to be entered.

13. a) Programming menu  

Channel B

Channel ...

End

Special
Program

PERMANENT

Ende

OK

M

OK

M

M

OK

12V

-

+

DCF

DC

OUTPUT

INPUT

SC 98.40 pro4

0

12

24

SP

SP

SP

SP

06.07.2020

MONTAG

9:28

00

GPS

DCF

INPUT

GPS

+

* depends on model

t

r q

s

D

C

B

A

s

1. To activate Bluetooth when time switch is active. 

END

BA SC88 SC98pro4 N; de,en -24136- 2020.06V01  

www.hugo-mueller.de

Hugo Müller GmbH & Co KG, Karlstraße 90, DE-78054 VS-Schwenningen

 [SC88.x0pro4 / SC98.x0pro4]

Summary of Contents for SC88. 0pro4 Series

Page 1: ...anal ON OFF 12 Permanent P Permanentschaltung durch 3 Sek Druck auf die ent sprechende Kanaltaste Kanal ist dauernd ein bzw ausgeschaltet Schaltung bleibt bis zur erneuten manuellen Umschaltung 3 Sek Druck bestehen f OK f 0 12 24 18 06 2020 9 2800 f OK f 0 12 24 f OK f 0 12 24 f OK f 0 12 24 f OK f 0 12 24 MONTAG PROGRAMM PROGRAMM NEU Kanal A Standard OK M f OK f 0 12 24 PROGRAMM 13 b Standardscha...

Page 2: ...eräte Anschluss Spannung c c Im Menü Optionen finden Sie den Punkt Eingang Sie müssen über diesen Optionspunkt festlegen ob ein Schalter oder Taster an den externen Eingang angeschlossen ist und welche Ausgangs Kanäle auf das externe Eingangssignal reagieren sollen Wählen Sie mit den r q Tasten aus ob Sie einen Taster oder Schalter anschließen bzw angeschlossen haben Bestätigen Sie Ihre Auswahl mit...

Page 3: ...onding channel button for more than 3 sec the channel is permanently switched ON or OFF The status remains until the next manual switching occurs 3 sec permanent over ride f OK f 0 12 24 18 06 2020 9 2800 f OK f 0 12 24 f OK f 0 12 24 f OK f 0 12 24 f OK f 0 12 24 MONday PROGRAM PROGRAM NEw Channel A Standard OK M f OK f 0 12 24 PROGRAM 13 b Standard weekly program Standard f OK f 0 12 24 Program ...

Page 4: ...ted channel No Then press s to confirm 26 Programming via Bluetooth 22 External Input Switch Pushbutton f OK f 0 12 24 Options Switch f OK f 0 12 24 input f OK f 0 12 24 yes No OK M pushbutton permanent On Permanent oFF SP activation OK M channel Kanal f OK f 0 12 24 Options Switch f OK f 0 12 24 input f OK f 0 12 24 Channel yes No OK M pushbutton change Function Timer Function staircase Lighting O...

Reviews: