Configuring the job computer
Entering field sprayer parameters
7
30303187-02-EN
V1.20180921
57
When the value is set to 0, this function is deactivated.
This parameter must be higher or the same as the “Sprayer off below” parameter.
“Regulation Factor” parameter
In Automatic mode, the spray pressure will be adapted to the current speed of the field sprayer. The
adjustment should ensure that the volume of spray liquid that is applied is exactly what you defined in
the target rate. The regulation factor plays a decisive role here.
The regulation factor adjusts the reaction speed of the regulation:
▪ The higher the regulation factor, the faster the spray pressure is adjusted.
▪ The lower the regulation factor, the more slowly the spray pressure is adjusted.
When setting the regulation factor, you can pay attention to the following:
▪ If, during movement at constant speed, the current application volume jumps around the target
value, you need to reduce the regulation factor.
▪ If, when speed is changing, the application volume does not adjust to the rate quickly enough,
you need to increase the regulation factor.
“Tank Size” parameter
Size of the tank for the spray liquid.
“Tank level alarm” parameter
When the volume of spray mixture in the tank falls below this value, an alarm message appears on
the screen.
“Impulses Main Flow” parameter
Number of impulses the flow meter sends to the job computer per one liter of liquid. Used to calculate
the application rate.
The number is determined by the flow meter calibration.
“Stirring off Below” parameter
With this parameter, you can set the fill level below which the stirrer should be switched off.
The implement manufacturer (not the user!) can also define whether the stirrer should be switched on
automatically when the job computer is started.
“Maximum Wind Speed” parameter
Wind sensor must be installed.
If the maximum wind speed is exceeded, an alarm will be triggered.
“Extremity nozzles set” parameter
With this parameter you can specify which extremity nozzles are mounted on the boom. More about
this in section: Extremity nozzles [
7.1.9
7.1.10
7.1.11
7.1.12
7.1.13
7.1.14