Mueller H-704 Operating Instructions Download Page 2

Mueller

®

 H-704 Hydraulic Power Operator

1. OPERATING INSTRUCTIONS

      CAUTION: Hydraulically driven 

power tools are not generally 

insulated against coming in contact 

with sources of electrical current. 

Take necessary precautions if 

sources of electrical current are 

nearby.

      WARNING: Operate this machine 

below the maximum rated pressure 

specified.
A.
 Be sure to read the Mueller Operating 

Instructions for the Mueller drilling 

machine that is being powered by the 

H-704 operator.

B. Install drilling machine on pipe 

according to the drilling machine’s 

operating manual.

C. After the drill or pilot drill has been 

positioned at the pipe according to 

the machine instructions, attach the 

operator to the machine.

A. Turn on the hydraulic unit and 

check the hydraulic pressure. Note 

maximum pressure permissible in 

the Specifications section of this 

instruction sheet (page 1).

B. Momentarily activate the on/off lever 

from the neutral position by pulling it 

toward the operator handle to assure 

the drill or shell cutter is turning in 

the correct direction. It should turn 

clockwise when observed from the 

operator end of the drilling machine.

      CAUTION: Moving the lever away 

from the operator handle will reverse 

the turning direction and could 

damage the tools during standard 

drilling or cutting operations.

C. Once the correct turning direction 

has been verified, activate the on/off 

lever by pulling it toward the operator 

handle and conduct the drilling 

operation according to the drilling 

machine operating manual.

2. CHECK THE DRILLING MACHINE SET UP

A. For drilling operations: Once the 

drilling is completed, follow the 

machine operating instructions to 

clear the tools from the pipe, return 

the drilling machine to its rear most 

position, and remove the operator 

from the machine.

B. For drilling and tapping operations: 

Once the tapping operation is 

completed, follow the machine 

operating instructions for reversing 

the operator, clearing the tools from 

the pipe, returning the machine to its 

rear most position, and removing the 

operator from the machine.

3. DISCONNECTING HYDRAULIC POWER OPERATOR

Reliable Connections

TM

Copyright © 2016 Mueller Co., LLC. All Rights Reserved.

The trademarks, logos and service marks displayed in this document herein are the property of Mueller Co., LLC, its affiliates or 

other third parties. Products above marked with a section symbol ( § ) are subject to patents or patent applications. For details, 

visit www.mwppat.com. These products are intended for use in potable water applications. Please contact your Mueller Sales or 

Customer Service Representative concerning any otherapplication(s).

!

!

!