background image

MI.NODE - WATER Installation Manual 

 

 

 

Rev 0.2 

Mueller Systems – Confidential 

Page 2 

 

The electronic design utilizes the latest RF microchip technology which increases 
reliability when compared to older RF designs 

 

3. Installation 

MI.NODE - WATER modules support two mounting options, either mounting to a ½” PVC 
pipe for pit set installations or affixed to the side of a building. Pit set installations require 

no drilled holes through the lid and are mounted beneath the polymer meter box lid for 
security and ease of installation on PVC pipe. Surface mounts are easily accomplished with 
the integral mounting brackets and two screws (not included). 

 

3.1  Pit Set Installation 

 

 Please note that meters or registers should never be carried while supported only by 

the AMR transmitter or wiring. 
 

Tools Required: Length of ½” PVC pipe for pit depth, hammer 
 

1.

 

PVC pipe should be cut to the proper length and installed deep 
enough in the floor of each meter box that subsequent flooding will 

not allow the stake and MI.NODE - WATER to change position. The 
MI.NODE - WATER includes a ½” female PVC pipe fitting for easy pit 

installation. 

2.

 

For maximum radio performance, once installed, the top of the 
transmitter should be located approximately ½” inch below the pit 

lid in the center of the meter box to maximize RF performance. 

3.

 

Once the PVC stake is installed, the MI.NODE - WATER should be 

pushed down onto the stake by hand until the interference fit 
engages securely, two solid stops are molded into the PVC 

Installation Slot in order to prevent the wire from being pinched 
when installed. 

 
 

 Never hammer MI.NODE - WATER onto the stake since this may result in damage 

to the electronic components inside the unit. 
 

3.2  Exterior Wall Mounting 

 

 Please note that meters or registers should never be carried while 

supported only by the AMR transmitter or wiring. 

 
Tools Required: 1 – 1 1/2 inch Galvanized, or Stainless Wood or Sheet Metal 

Screws (2 per), Phillips Screwdriver 
 

1.

 

The open ended wire from the device permits routing through interior 
walls for external wall mounting when required or direct mounting to 

exposed floor joists above grade level.   

2.

 

Mi.Node - Water can be directly mounted to almost any flat surface by 
using the holes shown and common screws in most instances. 

½” PVC 

Mounting Holes 

Summary of Contents for MI.NODE-WATER

Page 1: ...stems proprietary and confidential document shall not be reproduced or retransmitted in any way without expressed written consent from Mueller Systems Mi Node Water Installation Manual 880 0037 001 Do...

Page 2: ...on Manual Version 0 2 Created 05 28 2009 Last Modified On 05 29 2009 Author Tom Cullinan Technical Lead Contributors Revision History Version Date Author Comments 0 1 05 28 09 TC Initial draft submitt...

Page 3: ...llation 2 3 1 PIT SET INSTALLATION 2 3 2 EXTERIOR WALL MOUNTING 2 3 3 WIRING 3 3 4 VERIFICATION 3 4 Maintenance 3 5 Product Labeling 3 5 1 PRODUCT IDENTIFICATION 3 5 2 FCC IDENTIFICATION 4 Table of Ta...

Page 4: ...ide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance wi...

Page 5: ...een trained and are technically qualified in local safety procedures for installation of the device 2 Construction The MI NODE WATER product consists of a compact printed circuit board which is encaps...

Page 6: ...e MI NODE WATER includes a female PVC pipe fitting for easy pit installation 2 For maximum radio performance once installed the top of the transmitter should be located approximately inch below the pi...

Page 7: ...g installation the Mi Tech Hand held should be used to verify proper installation and operation Please refer to the Mi Tech manual 4 Maintenance There are no user serviceable items within a MI NODE WA...

Page 8: ...Rev 0 2 Mueller Systems Confidential Page 4 5 2 FCC Identification The text specified below is engraved into the bottom of the MI NODE WATER enclosure and indicates the FCC ID number of the product F...