1.3 MTX-Gateway Enclosure Drawings

Summary of Contents for MTX-GATEWAY

Page 1: ...USER GUIDE HARDWARE MTX GATEWAY SMART SOLUTIONS FOR A CHANGING WORLD WeAreConnectivity www mtxm2m com ...

Page 2: ...ystem Architecture and System Functionality 10 1 1 Block Diagram 10 1 2 Technical Data Electronics 10 1 2 1 External Interfaces 11 1 2 2 Internal Interfaces 11 1 2 3 User s Interfaces 11 1 2 4 System Components 11 1 3 Technical Data Mechanics Design 11 ELECTRONIC SPECIFICATIONS 12 1 External Interfaces 12 1 1 Function Specification 13 1 1 1 VGA 13 1 1 2 USB OTG 13 1 1 3 Ethernet 14 1 1 4 RS232 485...

Page 3: ...nts 34 4 1 Temperature Sensor 34 4 2 EEPROM 34 4 3 RTC 34 MECHANIC SPECIFICATIONS 35 1 Construction 35 1 1 PCB Outlines MTX Gateway 35 1 2 MTX Gateway PCB Top View 35 1 3 MTX Gateway Enclosure Drawings 36 1 4 MTX Gateway LC Enclosure Drawings 39 2 General Precautions 41 2 1 Protection Against External Effects 41 2 2 Thermal Management 41 SAFETY REQUIREMENTS AND PROTECTION REGULATIONS 42 1 Safety I...

Page 4: ...CIÓN DE CONFORMIDAD SPANISH 52 1 Estándares de homologación europea 52 2 Aprobación PTCRB 53 3 Conformidad FCC 54 3 1 Tasa de absorción específica SAR 54 4 Certificación AT T 56 REGULATORY AND TYPE APPROVAL INFORMATION 57 1 Directives and Standards 57 2 SAR Requirements Specific to Portable Mobiles 60 3 SELV Requirements 61 ROHS STATEMENT 62 DISPOSAL OF OLD ELECTRICAL AND ELECTRONIC EQUIPMENT DESC...

Page 5: ...based not be liable for any consequential incidental direct indirect punitive or other damages whatever including without limitation damages for loss of business profits business interruption loss of business information or data or other pecuniary loss arising out the use of or inability to use the documentation and or product even if Matrix Electronica S L U has been advised of the possibility of...

Page 6: ...ANGES 1 0 2013 07 RR First draft 1 1 2013 11 RR General update 1 2 2014 05 RR HW V1 02 update 1 3 2014 10 AEM TP Language style revision 1 4 2014 11 AEM Added mechanical drawings 1 5 2014 12 AEM Minor revision 1 6 2015 05 AEM Minor revision 1 7 2015 08 AEM Conformity assessment added 1 8 2015 12 AEM Minor revision 1 95 2017 06 JS Conformity assessment changes ...

Page 7: ... information about the components features connectors and signals available on the MTX Gateway 1 Product Label The label fixed to the bottom of a MTX devicel comprises the following information 1 MTX logo 2 Product name model 3 Part number ordering code 4 Hardware and firmware versions 5 Year week of fabrication 6 IMEI number 7 MAC address 8 Data matrix code IMEI 9 Data matrix code MAC 10 RoHS sym...

Page 8: ...ims any implied warranties of merchantability or fitness for any particular purpose with regard to any of the foregoing Matrix Electronica assumes no liability for any damages incurred directly or indirectly from any technical or typographical errors or omissions contained herein or for discrepancies between the product and the user guide In no event shall Matrix Electronica be liable for any inci...

Page 9: ...9 MTX Gateway 2019 4 MTX by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com REFERENCES STK MBa28 User Manual TQMa28 User Manual iMX28 Freescale Reference Manual ...

Page 10: ...RS232 transceiver LCD USB OTG ETH UART_0 UART_3 UART_1 CAN_0 I2C_1 GPIO_3 GPIO_4 SD USB Host I2C_1 UART_4 CAN transceiver RS232 transceiver ADV7125 1 wire DS2482 100 Relay Relay WiFi mini PCIe I2C_1 GPS RF Illustration 1 MTX Gateway block diagram 1 2 Technical Data Electronics The interfaces and system components listed in the following are implemented on the MTX Gateway Due to the fact that the b...

Page 11: ...net 1x RS232 485 422 2x RS232 1x CAN 1x 1 Wire Up to 2 x Relay 1x Power Supply 1 2 2 Internal Interfaces 1x TQMa28 1x miniPCIe Card 1x WiFi b g n 1x RF Card 1x Header for specific extension 1 2 3 User s Interfaces 6x Status LEDs 2x DIP switch 1 2 4 System Components Temperature sensor EEprom 1 3 Technical Data Mechanics Design Dimensions PCB WxDxH 111x118x25 mm Weight 500g ...

Page 12: ...2 MTX Gateway 2019 4 MTX by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com ELECTRONIC SPECIFICATIONS 1 External Interfaces Illustration 2 MTX Gateway PCB top view ...

Page 13: ...Type of media VGA Interface on module RGB 18bit Signal Characteristic Compatible with RS 343A and RS 170 1 1 2 USB OTG The USB OTG interface of the TQMa28 USB0 is offered as a Mini USB B Type Micro USB AB type or USB A type mounting option TQMa28 TPS2042 Ub3 Mini USB Micro USB USB Type of media USB OTG 2 0 Hi Speed 5V bus voltage limited to 500mA Interface on module USB OTG Signal characteristic C...

Page 14: ... AB OUPIIN 8968 A04C00RWA Right angle USB A 1 1 3 Ethernet The MTX Gateway directly drives the Ethernet 1 interface The SMSC LAN8720Ai is used as a PHY TQMa28 RJ45 Ue3 Ue2 LED DL3 LED DL2 LAN8720Ai Ue1 Type of media 10 100 Mbit Signal characteristic Compatible with the IEEE 802 3 standard Status LEDs 2 Modes MDI Auto MDIX Interface on module RMII ENET0 MANUFACTURER DESCRIPTION Oupiin 8949 H4D88 06...

Page 15: ... MAX3160 is used as a transceiver TQMa28 DB15 J6 J16 MAX3160 Uu3 Pluggable terminal J11 In addition two signals are used in order to configure the Maxim transceiver in one of its operational modes SIGNAL DESCRIPTION SW1_1 RS485 RS232 SW1_2 Half_Duplex Full_Duplex Transfer rate Up to 10Mbit s full duplex Interface on module AUART0 Handshake RTS used for clearing the transmission direction ESD prote...

Page 16: ...he DB15 of the RS232 485 422 interface DTE interface DB15 Connector pinout PIN SIGNAL TYPE REMARK 2 RXD0 I Receive Data 3 TXD0 O Transmit Data 7 RTS0 O Request to Send 8 CTS0 I Clear To Send 14 GND P Ground Pluggable terminal pinout J11 PIN SIGNAL TYPE REMARK 1 TXD0 O Transmit Data 2 RXD0 I Receive Data 3 RTS0 O Request to Send 4 CTS0 I Clear To Send 5 GND P Ground ...

Page 17: ... The Maxim MAX3221EEAE is used as a driver TQMa28 DB15 J6 J16 MAX3221 Uu1 Pluggable terminal J12 Transfer rate Up to 250Kbit s Interface on module AUART3 Handshake None ESD protection 15kV human body model The following tables show the configuration of the DB15 and Pluggable Terminals of the RS232_1 interface DB15 Connector pinout J6 J16 PIN SIGNAL TYPE REMARK 4 TXD1 O Transmit Data 9 RXD1 I Recei...

Page 18: ... 1 TXD1 O Transmit Data 2 RXD1 I Receive Data 3 GND P Ground 1 1 6 RS232_2 The AUART1 interface of the TQMA28 drives the RS232 interface of the MTX Gateway by default The Maxim MAX3221EEAE is used as a driver TQMa28 DB15 J6 J16 MAX3221 Uu2 Pluggable terminal J13 Transfer rate Up to 250Kbit s Interface on module AUART1 Handshake None ESD protection 15kV human body model ...

Page 19: ...llowing tables show the configuration of the DB15 and Pluggable Terminals of the RS232_2 interface DB15 Connector pinout J6 J16 PIN SIGNAL TYPE REMARK 4 TXD2 O Transmit Data 9 RXD2 I Receive Data 14 GND P Ground Pluggable terminal pinout J13 PIN SIGNAL TYPE REMARK 1 TXD2 O Transmit Data 2 RXD2 I Receive Data 3 GND P Ground ...

Page 20: ...AN transceiver TQMa28 DB15 J6 J16 MAX3221 U3 Pluggable terminal J12 Transfer rate Up to 1Mbit s Interface on module CAN_0 Signal characteristic Compatible with the ISO 11898 standard CAN 2 0B ESD protection 8kV human body model The following tables show the configuration of the DB15 and Pluggable Terminals of the CAN interface DB15 Connector pinout J6 J16 PIN SIGNAL TYPE REMARK 1 CANH I O CAN High...

Page 21: ...N SIGNAL TYPE REMARK 4 CANH I O CAN High Level I O 5 CANL I O CAN Low Level I O 1 1 8 1 Wire A 1 Wire interface is available on the MTX Gateway via the Maxim DS2482 100 I2C chip TQMa28 DB15 J6 J16 DS2482 100 U2 Pluggable terminal J13 Transfer rate Up to 400kHz Interface on module I2C1 Signal characteristic Standard and Overdrive 1 Wire communication ...

Page 22: ...om The following tables show the configuration of the DB15 and Pluggable Terminals of the 1 Wire interface DB15 Connector pinout J6 J16 PIN SIGNAL TYPE REMARK 5 1 Wire I O 1 Wire Pluggable terminal pinout J13 PIN SIGNAL TYPE REMARK 5 1 Wire I O 1 Wire I2C BUS POSITION DEVICE ADDRESS 1 MTX Gateway 1 Wire DS2482 0x18 ...

Page 23: ...its required corresponding relay TQMa28 2 coil latching Up to 2 Up to 2 1x LY relay Option A Option B Option C Option D In order to control the chosen relay the following TQMa28 GPIOs are available GPIO TQMa28 internal GPIO reference GPIO_3 gpio0_7 GPIO_4 gpio0_16 Option A The GPIO_3 drives the SET coil of the Latching Relay meanwhile the GPIO_4 drives the Reset coil The placement for this option ...

Page 24: ...m2m com PIN SIGNAL TYPE REMARK 1 RL_COM O Common 2 RL_NC O Normally Closed 3 RL_NA O Normally Open Option B C and D Each GPIO drives one different Relay The placement for this option is showed on the following picture J17 and J18 PIN SIGNAL TYPE REMARK 1 NA O Normally Open 2 COM O Common 3 NC O Normally Closed ...

Page 25: ...ned very robustly PLUG CONNECTOR 90 230VAC 120 370VDC J7 Fuse 0 5A AC DC Out 15VDC SWITCHING REGULATOR 5V SWITCHING REGULATOR 3 3V PLUG CONNECTOR 7 50VDC J8 Line Filter Vout 15VDC Rev polarity protection COMMON OPTION A OPTION B Configuration Option A PARAMETER MIN TYP MAX UNIT AC Input Voltage 90 240 264 V DC Input Voltage 120 370 V Input current 220 mA Power consumption 3 W Rated current of the ...

Page 26: ...METER MIN TYP MAX UNIT AC Input Voltage 5 35 V Power consumption 3 W 2 Internal Interfaces 2 1 TQMa28 The core of the MTX GTW is the TQ Components TQMa28 module The following table shows the key features of this module FEATURE DESCRIPTION Processor Freescale iMX287 454MHz RAM 128MB DDR2 FLASH 4GB eMMC EEPROM 32Kb Detailed information about this module can be found on the following link http www tq...

Page 27: ...hows the buses supported by the device BUS REMARK USB USB 2 0 SIM UIM signals for GSM and WCDMA applications Diagnostics LEDs LED_WWAN Control signals PERST WDISABLE One of the following miniPCIe Cards already tested by Matrix Electronica can be included on the MTX Gateway NAME DESCRIPTION EHS5 E Dual Band UMTS WCDMA FDD 900 2100 MHz BGS2 W GPRS Class 10 EWM W150H01E USB WiFi 802 11 b g n Ralink R...

Page 28: ... WPA and WPA2 Operation mode Supports Client and Access Point Up to 8 clients Module interface SDIO 2 4 RF Card An RF Card connector is available on the MTX Gateway Two complete UART interfaces RX TX CTS RTS I2C and 3 GPIOs are available on this connector The following table shows the connector pinout MOD1 PIN SIGNAL TYPE REMARK 1 UART4_RX I UART4 Receive Data 2 UART4_TX O UART4 Transmit Data 3 GP...

Page 29: ...m2m com SALES info mtxm2m com mtxm2m com 12 UART4_RTS O UART4 Request to Send 13 I2C_SCL O I2C Clock signal 14 I2C_SDA I O I2C Data signal 15 UART3_RX I UART3 Receive Data 16 UART3_TX O UART3 Transmit Data 17 UART3_CTS I UART3 Clear to Send 18 UART3_RTS O UART3 Request to Send ...

Page 30: ...ecard module The following table shows the key features of this module FEATURE DESCRIPTION Frequency 868 433 915MHz Network Topology Point to Point Star and Mesh Typical Transfer rate 9 6 kbps 433 868 MHz 19 2 kbps 915MHz Line of sight 25mW Up to 1km 500mW Up to 4km Dimensions 25mW 30x28x7 mm 500mW 37x30x7 mm Detailed information about this module can be found on the following link http www coroni...

Page 31: ... RF The MOD1 connector also supports the connection of the Matrix Electronica MOD RF module The following table shows the key features of this module FEATURE DESCRIPTION RF Technology Bluetooth 2 1 Bluegiga WT12 Bluetooth 4 0 Bluegiga BLE112 Xbee Form Factor compatible RF 2 4GHz Amber 8426 868 WMBUS 2 5 Extension Header T B D ...

Page 32: ...nform the user about different status conditions The following table shows the different LED indications LED STATUS REMARK DL1 Connected to miniPCIe Card WWLAN signal DLp1 On when 5VCC is good DL4 On when 3 3VCC is good DL2 Ethernet link activity LED indication DL3 Ethernet link speed LED indication On with 100Mbps OFF with 10Mbps DLp2 Free for User information Connected to gpio3_6 ...

Page 33: ... SIGNAL REMARK 8 LCD_D04 Booting Configuration Signals Check TQMa28 User Guide for more information 7 LCD_D03 6 LCD_D02 5 LCD_D01 4 LCD_D00 3 LCD_RS 2 LCD_DEBUG 1 GPIO_6 Input signal for User information Connected to gpio0_24 SW1 PIN SIGNAL REMARK 1 SW2_1 Connected to RS485 RS232 Default OFF RS232 2 SW2_2 Connected to Half_Duplex Full_Duplex Default OFF Full Duplex 3 3 3VDC VCC_OUT J6 J16 ON 3 3VD...

Page 34: ... Temperature sensor LM73 0x49 4 2 EEPROM A 64Kibit EEPROM ST Microelectronics M24C64 WDW6TP is on the TQMa28 module The EEPROM is controlled via the processor s I2C bus 1 Writing protection WP of the EEPROM is not available The base address can be taken from the following table I2C BUS POSITION DEVICE ADDRESS 1 TQMa28 EEPROM M24C46 0x50 4 3 RTC A DS1339U RTC module is on the MTX Gateway board The ...

Page 35: ... by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com MECHANIC SPECIFICATIONS 1 Construction PCB outlines including mounting holes 1 1 PCB Outlines MTX Gateway 1 2 MTX Gateway PCB Top View ...

Page 36: ...36 MTX Gateway 2019 4 MTX by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com 1 3 MTX Gateway Enclosure Drawings ...

Page 37: ...37 MTX Gateway 2019 4 MTX by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com ...

Page 38: ...38 MTX Gateway 2019 4 MTX by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com ...

Page 39: ...39 MTX Gateway 2019 4 MTX by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com 1 4 MTX Gateway LC Enclosure Drawings ...

Page 40: ...40 MTX Gateway 2019 4 MTX by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com ...

Page 41: ...bought as a standalone product the following points must be considered 2 1 Protection Against External Effects The MTX Gateway PCB is not protected against dust external impact and contact IP00 An adequate protection has to be guaranteed by the surrounding system 2 2 Thermal Management The main heat source is the TQMa28 in case of the use of a miniPCIe Card this also has to be taken into account I...

Page 42: ...e used in hospitals airports or planes Never use the device at a gas station refuelling point blasting area or in any other environment where explosives may be present Operating the device close to other electronic devices such as antennas television sets and radios may cause electromagnetic interference This product is intended to be used with the antenna or other radiating element at least 20cm ...

Page 43: ...y invalidate the warranty The MTX Gateway terminal must not be installed nor located in areas where the surface temperature of the plastic case could exceed 85 C In order to provide strain relief and to avoid transmitting excessive vibration to the device during installation all cables connected to the MTX Gateway terminal must be secured or clamped immediately adjacent to the device s connectors ...

Page 44: ...rostatic discharges When the SIM card hatch is opened the SIM card connectors lie exposed under the SIM card holder Caution Do not touch these connectors If you do you may release an electrical discharge that could damage the modem or the SIM card When designing your application the SIM card s accessibility should be taken into account We always recommend that you have the SIM card protected by a ...

Page 45: ...bile station the antenna of the modem emits radio frequency energy To avoid EMI electromagnetic interference you must determine whether the application itself or equipment in the application s proximity needs further protection against radio emission and the disturbances it might cause Protection is secured either by shielding the surrounding electronics or by moving the antenna away from the elec...

Page 46: ...f all persons regardless of age and health and to account for any variations in measurements Specific Absorption Rate SAR is the unit of measurement for the amount of radio frequency energy absorbed by the body when using a transceiver The SAR value is determined at the highest certified power level in laboratory conditions but the actual SAR level of the transceiver while operating can be well be...

Page 47: ...tion of cardiac pacemakers hearing aids and certain other implanted equipment If a minimum distance of 15 cm 6 inches is maintained between the MTX Gateway modem radiating antenna and a pacemaker the risk of interference is limited If the user s application is likely to be situated in the vicinity of personnel a suitable warning should be contained in the equipment manual to this effect ...

Page 48: ...y LC OEM 199802107 object of the declaration described above is in conformity with the relevant Union harmonization Legislation RED Directive 2014 53 EU and R TTE Directive 99 5 EC The following harmonized standards and or other normative documents were applied are labeled with the CE conformity mark EMC art 3 1 b EN 301 489 1 V2 2 0 EN 301 489 52 V1 1 0 EN 301 489 3 V2 1 1 RADIO SPECTRUM art 3 2 ...

Page 49: ...quipment Authorization Certification for the EHS6 Module is listed under the FCC identifier QIPEHS6 Industry Canada Certification Number 7830A EHS6 granted to Gemalto M2M GmbH The Cinterion reference application of the EHS6 Module registered under the above identifier is certified to be in accordance with the following Rules and Regulations of the Federal Communications Commission FCC Power listed...

Page 50: ...7 CFR 1 1310 with 0 55773 mW cm The maximum measured power output in the 1900 MHz band is 974 99 mW 29 89 dBm see 7layers test report MDE_Siem_0714_FCCc The maximum permissible exposure is defined as 47 CFR 1 1310 with 1 mW cm According to the limit in 47 CFR 1 1310 we get the value of the maximum antenna gain as follows S P G 4πR S 0 55773 mW cm or 1 mW cm P 1866 38 mW or 974 99 mW R 20 cm or 100...

Page 51: ...ive impacts on AT T s wireless network Baseline regulatory confirmation RF testing against components in the wireless AT T network Network selection testing The MTX Gateway device was not observed to cause any adverse problems to the AT T network when activated and used in the lab The MTX 3G JAVA is certified for both CS and PS services as applicable Any change to the mode of operation invalidates...

Page 52: ...refiere esta declaración están están conformes con la Directiva RED 2014 53 EU EMC art 3 1 b EN 301 489 1 V2 2 0 EN 301 489 52 V1 1 0 EN 301 489 3 V2 1 1 RADIO SPECTRUM art 3 2 EN 301 511 V12 5 1 EN 301 908 1 V11 1 1 EN 301 908 2 V11 1 1 EN 300 440 V2 1 1 SAFETY art 3 1 a EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 RF SAFETY EN62311 2008 Estos estándares armonizados permiten etiquetar al pro...

Page 53: ...o norteamericano MTX Gateway tiene la certificación PTCRB Solicitud 39216 Fabricante Matrix Electronica Modelo MTX Gateway Tecnologías y bandas de frecuencias GSM 850 900 1800 1900 UMTS FDD Band I Band II Band V Band VIII FCCID QIPEHS6 Industry Canada 7830A EHS6 IMEI TAC 35888405 Version Hardware 1 12 Version Software 02 000 SVN 08 NAPRD 03 Version GSM Test 5 15 OTA Performance Test 5 1 ...

Page 54: ... GPRS Modem 3 1 Tasa de absorción específica SAR El módulo Cinterion EHS6 es comercializado sin una antena definida La ganancia máxima de antena usando antenas de interior depende de la distancia de esta a las personas cercanas y en condiciones normales no debe sobrepasar los límites mostrados en la tabla siguiente La máxima potencia de salida medida en la banda de 850MHz es 1866 38 mW 32 71 dBm v...

Page 55: ...CTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com Despejando G la máxima ganancia de antena es BANDA DISTANCIA GANANCIA MÁXIMA EN dBi 850MHz 20cm 1 7669 850MHz 50cm 9 7257 1900MHz 20cm 7 1227 1900MHz 50cm 15 0815 ...

Page 56: ...brica de AT T Confirmación del cumplimiento de la normativa básica aplicable Prueba de RF contra los distintos components usados en la red de AT T Prueba de selección de red El dispositivo MTX Gateway no ha evidenciado ni causado ningún tipo de problema en la red de AT T cuando ha sido activado y utilizado en el laboratorio El MTX 3G JAVA está certificado para servicios CS y PS Cualquier cambio en...

Page 57: ...ed with the CE conformity mark ECE R 10 Economic Commission for Europe ECE Regulation No 10 Uniform provisions concerning the approval of vehicles with regard to electromagnetic compatibility 2002 95 EC RoHS 1 2011 65 EC RoHS 2 Directive of the European Parliament and of the Council of 27 January 2003 and revised on 8 June 2011 on the restriction of the use of certain hazardous substances in elect...

Page 58: ...llary equipment of digital cellular radio telecommunications systems GSM and DCS ETSI EN 301 489 24 V1 5 1 Electromagnetic Compatibility and Radio spectrum Matters ERM Electromagnetic Compatibility EMC standard for radio equipment and services Part 24 Specific conditions for IMT 2000 CDMA Direct Spread UTRA for Mobile and portable UE radio and ancillary equipment EN 301 908 01 V5 2 1 Electromagnet...

Page 59: ... Pollution Caused by Electronic Information Products 2006 06 According to the Chinese Administration on the Control of Pollution caused by Electronic Information Products ACPEIP the EPUP i e Environmental Protection Use Period of this product is 20 years as per the symbol shown here unless otherwise marked The EPUP is valid only as long as the product is operated within the operating limits descri...

Page 60: ...EN 59005 ANSI C95 1 Considerations for evaluation of human exposure to Electromagnetic Fields EMFs from Mobile Telecommunication Equipment MTE in the frequency range 30MHz 6GHz Products intended for sale in European markets EN 50360 Product standard to demonstrate the compliance of mobile phones with the basic restrictions related to human exposure to electromagnetic fields 300MHz 3GHz Please note...

Page 61: ...by MATRIX ELECTRONICA S L U SUPPORT iotsupport mtxm2m com SALES info mtxm2m com mtxm2m com 3 SELV Requirements The power supply connected to the MTX Gateway shall be in compliance with the SELV requirements defined in EN 60950 1 ...

Page 62: ... SALES info mtxm2m com mtxm2m com ROHS STATEMENT The MTX Gateway modem is compliant with the 2002 95 EC Directive of the European Parliament and of the Council of 27 January 2003 on the restriction of the use of certain hazardous substances in electrical and electronic equipment RoHS ...

Page 63: ...d over to an applicable collection point for the recycling of electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences to the environment and human health which could otherwise be caused by inappropriate disposal of this product The recycling of materials will help to conserve natural resources For more detailed inf...

Page 64: ...m SALES info mtxm2m com mtxm2m com MTBF Standard IEC61709 SN 29500 Electronic components Reliability Reference conditions for failure rates and stress models for conversion Ambient temperature 25ºC 24h day powered and 22h day idle mode 2h day talktime MTTF h 1685393 MTTF year 192 40 ...

Page 65: ...ona Spain Phone 902 19 81 46 Fax 902 99 54 14 MATRIX DURANGO Matrix Electrónica S L Pol Aliendalde 11 oficina 2G 48200 Durango Vizcaya Spain Phone 902 19 81 46 Fax 902 99 54 14 MATRIX VALENCIA Matrix Electrónica S L Valencia Spain Phone 902 19 81 46 Fax 902 99 54 14 MATRIX SEVILLA Matrix Electrónica S L Torneo Parque Empresarial C Arquitectura 1 Torre 6 41015 Sevilla Spain Phone 902 19 81 46 Fax 9...

Reviews: