3.3
Storage conditions
The conditions stated below are only valid for modems in their original packed state in weather
protected, non-temperature-controlled storage locations. Normal storage time under these
conditions is a maximum of 12 months. The units will be delivered in a packaging that meets the
requirements according “IPD/JEDEC J-STD-033B.1” for Low Temperature Carriers.
Type
Condition
Unit
Reference
Air temperature: Low
High
-30
+75
ºC
ETS 300 019-2-1: T1.2, IEC 60068-2-1 Ab
ETS 300 019-2-1: T1.2, IEC 60068-2-2 Db
Relative humidity: Low
High
Condensation
10
90 at 30ºC
90-100 at 30ºC
%
---
ETS 300 019-2-1: T1.2, IEC 60068-2-56 Cb
ETS 300 019-2-1: T1.2, IEC 60068-2-30 Db
Air pressure: Low
High
70
106
kPa
IEC TR 60271-3-1:1K4
IEC TR 60271-3-1:1K4
Movement of surrounding air
1.0
m/s
IEC TR 60271-3-1:1K4
Water: rain, dripping, icing and
frosting
Not allowed
-
-
Radiation: Solar
Heat
1120
600
W/m2
ETS 300 019-2-1: T1.2, IEC 60068-2-2Bb
ETS 300 019-2-1: T1.2, IEC 60068-2-2Bb
Chemically active substances
Not recommended
IEC TR 60271-3-1:1C1L
Mechanically active substances
Not recommended
IEC TR 60271-3-1:1S1
Sinusoidal vibration:
Displacement
Acceleration
Frequency range
1.5
5
2-9 9-200
mm
m/s2
Hz
IEC TR 60271-3-1:1M2
Shocks:
Shock spectrum
Duration
Acceleration
semi-sinusoidal
1
50
ms
m/s2
IEC 60068-2-27 Ea