![MTU 12 V 2000 M72 Operating Instructions Manual Download Page 49](http://html1.mh-extra.com/html/mtu/12-v-2000-m72/12-v-2000-m72_operating-instructions-manual_1852627049.webp)
3.4 16 V 2000 M72 engine data: Separate heat exchanger, EPA
stage 2
Explanation:
DL Ref. value: Continuous power
BL Ref. value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
Reference conditions
Engine model
16V2000
M72
Application group
1B
Intake air temperature
°C
25
Raw water inlet temperature
°C
25
Barometric pressure
mbar
1000
Site altitude above sea level
m
100
Power-related data (power ratings are net brake power as per ISO 3046)
Number of cylinders
16
Rated engine speed
A
rpm
2250
Fuel stop power ISO 3046
A
kW
1440
General conditions (for maximum power)
Number of cylinders
16
Intake depression (new filter)
A
mbar
15
Intake depression, max.
L
mbar
30
Model related data (basic design)
Number of cylinders
16
Cylinder arrangement: V angle
Degrees
90
Bore
mm
135
Stroke
mm
156
Cylinder displacement
Liters
2.23
Total displacement
Liters
35.68
Number of inlet valves per cylinder
2
Number of exhaust valves per cylinder
2
M015650/05E 2014-03
| Technical Data | 49
TIM-ID: 0000010937 - 003